Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Bulletin of the American Physical Society

Observation of optical quantum measurement backaction on a mechanical resonator

Thomas Purdy, Robert W. Peterson, Pen-Li Yu, Cindy A. Regal

Published Mar 19, 2013• 0 citations
OpenAlex

Related papers

Observation of quantum-measurement backaction with an ultracold atomic gas

Kater W. Murch, Kevin L. Moore, Subhadeep Gupta +1 more

arXiv:0706.1005•Nature Physics•May 18, 2008•431 citations

Mechanical resonators and quantum measurements

Hiroshi Yamaguchi

The Japan Society of Applied Physics•Jul 8, 2014•0 citations

Quantum and dynamical back-action effects using a gram-scale mechanical resonator in a high-finesse optical cavity

Alexandros Tavernarakis

Cavity Optomechanics, that is the study of the interaction between an optical cavity mode and a mechanical degree of freedom, has known impressive evolution over the past decade, to become a new field at the union of condensed matter physics and optics. One of the major goals of this discipline is to test and study quantum mechanics using macroscopic systems. Among the most fundamental problems the community aims to address is the question of the quantum limits in position measurement. Quantum mechanics predicts that any measurement comes along with a backaction, which perturbs the state of the measured system. Moreover, it is expected to be conjugated with the quantum noise of the measurement apparatus (called measurement noise) used to probe the system. The optimal sensitivity is reached whenever both the measurement and the backaction noise are identical, a situation which can be assimilated to the acceptance of Heisenberg's inequality for the measurement apparatus. In cavity optomechanics, the mode of an optical cavity is used as a measurement apparatus of the position of a mechanical resonator which is expected to be responsible for the backaction imprecision. However, this so-called radiation pressure quantum backaction has never been observed to date, while it remains a decisive step towards understanding quantum measurement processes. We describe in this manuscript the study of radiation pressure effects in cavity optomechanics. We introduce the optomechanical system we have developed, which consists in a cm-scale ultra high Q (~ 1 000 000) plano-convex mechanical resonator incorporated into a ultra-high finesse (~ 300 000) Fabry-Prot cavity. We present two important results we obtained with this system. First, we were able to report the first direct observation of radiation pressure in real-time, based on establishing pump-probe correlations. We were also able to demonstrate for the first time nonlinear backaction effects related to substantial improvement of position measurement sensitivity. We explain why demonstrating quantum backaction requires ultra-high stability of the optical mode. We present important changes made to the previous experimental setup, notably on the laser source, on the detection and the stabilization of the experiment. We then describe a new optomechanical detection technique providing an independent measurement of the cavity detuning. Finally, we present a proof-of-principle experiment allowing to extract quantum optomechanical correlations at room temperature.

•Dec 20, 2012•0 citations

Back action evading quantum limited measurements of a nanomechanical resonator

Tchefor Ndukum, Tristan O. Rocheleau, Jared Hertzberg +1 more

Bulletin of the American Physical Society•Mar 20, 2009•0 citations

Quantum Measurement Backaction and Upconverting Microwave Signals with Mechanical Resonators

Robert W. Peterson

The limits of optical measurement and control of mechanical motion are set by the quantum nature of light. The familiar shot noise limit can be avoided by increasing the optical power, but at high enough powers, the backaction of the randomly-arriving photons' radiation pressure can grow to become the dominant force on the system. This thesis will describe an experiment showing how backaction limits the laser cooling of macroscopic drumhead membranes, as well as work on how these membranes can be used to upconvert microwave signals to optical frequencies, potentially preserving the fragile quantum state of the upconverted signal.

•Jan 1, 2017•1 citation

Quantum Measurement of a Mechanical Resonator At and Below the Standard Quantum Limit

Massimiliano Rossi, David Mason, Junxin Chen +2 more

Conference on Lasers and Electro-Optics•Jan 1, 2019•0 citations
Cavity Optomechanics, that is the study of the interaction between an optical cavity mode and a mechanical degree of freedom, has known impressive evolution over the past decade, to become a new field at the union of condensed matter physics and optics. One of the major goals of this discipline is to test and study quantum mechanics using macroscopic systems. Among the most fundamental problems the community aims to address is the question of the quantum limits in position measurement. Quantum mechanics predicts that any measurement comes along with a backaction, which perturbs the state of the measured system. Moreover, it is expected to be conjugated with the quantum noise of the measurement apparatus (called measurement noise) used to probe the system. The optimal sensitivity is reached whenever both the measurement and the backaction noise are identical, a situation which can be assimilated to the acceptance of Heisenberg's inequality for the measurement apparatus. In cavity optomechanics, the mode of an optical cavity is used as a measurement apparatus of the position of a mechanical resonator which is expected to be responsible for the backaction imprecision. However, this so-called radiation pressure quantum backaction has never been observed to date, while it remains a decisive step towards understanding quantum measurement processes. We describe in this manuscript the study of radiation pressure effects in cavity optomechanics. We introduce the optomechanical system we have developed, which consists in a cm-scale ultra high Q (~ 1 000 000) plano-convex mechanical resonator incorporated into a ultra-high finesse (~ 300 000) Fabry-Prot cavity. We present two important results we obtained with this system. First, we were able to report the first direct observation of radiation pressure in real-time, based on establishing pump-probe correlations. We were also able to demonstrate for the first time nonlinear backaction effects related to substantial improvement of position measurement sensitivity. We explain why demonstrating quantum backaction requires ultra-high stability of the optical mode. We present important changes made to the previous experimental setup, notably on the laser source, on the detection and the stabilization of the experiment. We then describe a new optomechanical detection technique providing an independent measurement of the cavity detuning. Finally, we present a proof-of-principle experiment allowing to extract quantum optomechanical correlations at room temperature.
The limits of optical measurement and control of mechanical motion are set by the quantum nature of light. The familiar shot noise limit can be avoided by increasing the optical power, but at high enough powers, the backaction of the randomly-arriving photons' radiation pressure can grow to become the dominant force on the system. This thesis will describe an experiment showing how backaction limits the laser cooling of macroscopic drumhead membranes, as well as work on how these membranes can be used to upconvert microwave signals to optical frequencies, potentially preserving the fragile quantum state of the upconverted signal.