A bright beam of metastable helium atoms is useful in various studies. Laser spectroscopy of helium in an atomic beam can provide a determination of the fine-structure constant and the nuclear charge radius, towards a test of quantum electrodynamics (QED). In these measurements, it is necessary to control not only the internal quantum state but also the translation motion of the helium atom. Here we present a setup producing an intense and speed-adjustable continuous beam of helium atoms. By using a combination of laser cooling, focusing, and deflection, helium atoms are prepared at the single quantum state of
23S1 (
m=0), with a very narrow distribution of the longitudinal speed ($\ensuremath{\delta}{v}_{z}<\ifmmode\pm\else\textpm\fi{}4.5$ m/s). At the same time, we obtain a flux of $1.8\ifmmode\times\else\texttimes\fi{}{10}^{13}$ (atoms/s)/sr with a fractional fluctuation below 0.02%. The atomic-beam quality was investigated by laser spectroscopy, indicating a considerable improvement over those used in previous helium precision-spectroscopy measurements.
We report on interference studies in the internal and external degrees of freedom of metastable triplet helium atoms trapped near quantum degeneracy in a $$1.5 \,\upmu {\mathrm{m}}$$ optical dipole trap. Applying a single
π/2 rf pulse we demonstrate that 50% of the atoms initially in the
m=+1 state can be transferred to the magnetic field insensitive
m=0 state. Two
π/2 pulses with varying time delay allow a Ramsey-type measurement of the Zeeman shift for a high precision measurement of the
23S1 –
21S0 transition frequency. We show that this method also allows strong suppression of mean-field effects on the measurement of the Zeeman shift, which is necessary to reach the accuracy goal of 0.1 kHz on the absolute transition frequencies. Theoretically the feasibility of using metastable triplet helium atoms in the
m=0 state for atom interferometry is studied demonstrating favorable conditions, compared to the alkali atoms that are used traditionally, for a non-QED determination of the fine structure constant.
Abstract We report on interference studies in the internal and external degrees of freedom of metastable triplet helium atoms trapped near quantum degeneracy in a $$ 1.5\kern0.166667em \upmu \mathrm{m} $$ 1.5 μ m optical dipole trap. Applying a single
π/2 π / 2 rf pulse we demonstrate that 50% of the atoms initially in the
m=+1 m = + 1 state can be transferred to the magnetic field insensitive
m=0 m = 0 state. Two
π/2 π / 2 pulses with varying time delay allow a Ramsey-type measurement of the Zeeman shift for a high precision measurement of the
23S1 2 3 S 1 –
21S0 2 1 S 0 transition frequency. We show that this method also allows strong suppression of mean-field effects on the measurement of the Zeeman shift, which is necessary to reach the accuracy goal of 0.1 kHz on the absolute transition frequencies. Theoretically the feasibility of using metastable triplet helium atoms in the
m=0 m = 0 state for atom interferometry is studied demonstrating favorable conditions, compared to the alkali atoms that are used traditionally, for a non-QED determination of the fine structure constant.