Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:0704.3430 · The European Physical Journal D

Prospects for precision measurements of atomic helium using direct frequency comb spectroscopy

E. E. Eyler, D. E. Chieda, M. C. Stowe, Michael J. Thorpe, T. R. Schibli, J. Ye

Published Oct 16, 2007• 56 citations
arXivHTMLPDF
DOI
10.1140/epjd/e2007-00289-y

Related papers

Two-photon Direct Frequency Comb Spectroscopy of Alkali Atoms

Christopher Palm, Trinity Pradhananga, Khoa Nguyen +2 more

Bulletin of the American Physical Society•Jun 7, 2012•0 citations

Optical Frequency Comb Spectroscopy of Rare Earth Atoms

Jerlyn L. Swiatlowski, Christopher Palm, Trinity Joshi +2 more

Bulletin of the American Physical Society•Jun 5, 2013•0 citations

Direct Frequency Comb Spectroscopy and High-Resolution Coherent Control

Matthew C. Stowe

•Jan 1, 2008•2 citations

Towards Direct Frequency Comb Spectroscopy Using Quantum Logic

Gottfried Wilhelm, Doktor der Naturwissenschaften

•Jan 1, 2011•3 citations

Estimation of One- and Two-Photon Rydberg Transition Rates in Helium Driven Directly by an Optical Frequency Comb

Drew Procyk, Edward E. Eyler, Robin J. Jones +3 more

Bulletin of the American Physical Society•May 19, 2006•0 citations

Electro-optic frequency comb Doppler thermometry

Sean M. Bresler, Erin M. Adkins, Stephen P. Eckel +4 more

We demonstrate a Doppler thermometer based on direct optical frequency comb spectroscopy of an $^{85}$Rb vapor with a chirped electro-optic frequency comb (EOFC). The direct EOFC Doppler thermometer is accurate to within its approximately 1 K statistical uncertainty. We experimentally compare direct EOFC spectroscopy with conventional Doppler spectroscopy using a single-frequency, step-scanned laser probe. Our results show that direct EOFC spectroscopy mitigates transit-induced optical pumping distortion of the atomic lineshape, which is the dominant systematic temperature shift in alkali atom Doppler thermometry. Optical Bloch equation simulations of conventional and direct EOFC Doppler spectroscopy confirm that EOFC spectroscopy can use higher optical power to reduce statistical noise without optical pumping distortion. Our results indicate that EOFC Doppler thermometry is a promising approach to realizing a primary thermometer with size and measurement rate sufficient for applications including pharmaceutical manufacturing and nuclear waste monitoring.

physics.atom-phCross-listedarXiv:2601.10575•Jan 16, 2026
We demonstrate a Doppler thermometer based on direct optical frequency comb spectroscopy of an 85^{85}85Rb vapor with a chirped electro-optic frequency comb (EOFC). The direct EOFC Doppler thermometer is accurate to within its approximately 1 K statistical uncertainty. We experimentally compare direct EOFC spectroscopy with conventional Doppler spectroscopy using a single-frequency, step-scanned laser probe. Our results show that direct EOFC spectroscopy mitigates transit-induced optical pumping distortion of the atomic lineshape, which is the dominant systematic temperature shift in alkali atom Doppler thermometry. Optical Bloch equation simulations of conventional and direct EOFC Doppler spectroscopy confirm that EOFC spectroscopy can use higher optical power to reduce statistical noise without optical pumping distortion. Our results indicate that EOFC Doppler thermometry is a promising approach to realizing a primary thermometer with size and measurement rate sufficient for applications including pharmaceutical manufacturing and nuclear waste monitoring.