Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

The Japan Society of Applied Physics

Characterization of interleaved four elements superconducting single photon detector

Shigehito Miki

Published Jul 17, 2015• 0 citations
OpenAlex

Related papers

Multi-element superconducting single-photon detector

Enam Khan, Alexander V. Divochiy, Vadim Aleksandrovich Seleznev +2 more

•Jan 1, 2015•0 citations

Evaluation of 16 element superconducting nanostrip single photon detector

Shigehito Miki, Shigeyuki Miyajima, Masahiro Yabuno +2 more

IEICE Technical Report; IEICE Tech. Rep.•Nov 18, 2020•0 citations

Characterization of 64 pixels superconducting single photon detector

Shigehito Miki

The Japan Society of Applied Physics•Feb 6, 2014•0 citations

Characterization of superconducting nanowire avalanche single photon detector

Shigehito Miki, Taro Yamashita, Hirotaka Terai

The Japan Society of Applied Physics•Feb 8, 2016•0 citations

Characterization of Superconducting Single Photon Detectors Fabricated on MgO Substrates

Roberto Leoni, Alessandro Gaggero, F. Mattioli +7 more

Journal of Low Temperature Physics•Jan 10, 2008•4 citations

Improving photon number resolvability of a superconducting nanowire single-photon detector array using a level comparator circuit

Jia Huang, Xingyu Zhang, Weijun Zhang +7 more

Abstract Photon number resolving (PNR) capability is very important in many optical applications, including quantum information processing, fluorescence detection, and few-photon-level ranging and imaging. Superconducting nanowire single-photon detectors (SNSPDs) with a multipixel interleaved architecture give the array an excellent spatial PNR capability. However, the signal-to-noise ratio (SNR) of the PNR (SNRPNR) of the array will be degraded with increasing the element number due to the electronic noise in the readout circuit, which limits the PNR resolution as well as the maximum PNR number. In this study, a 16-element interleaved SNSPD array was fabricated, and the PNR capability of the array was investigated and analyzed. By introducing a level comparator circuit (LCC), the SNRPNR of the detector array was improved over a factor of four. In addition, we performed a statistical analysis of the photon number on this SNSPD array with LCC, showing that the LCC method effectively enhances the PNR resolution. Besides, the system timing jitter of the detector was reduced from 90 ps to 72 ps due to the improved electrical SNR.

Superconductor Science and Technology•Apr 9, 2024•7 citations
Abstract Photon number resolving (PNR) capability is very important in many optical applications, including quantum information processing, fluorescence detection, and few-photon-level ranging and imaging. Superconducting nanowire single-photon detectors (SNSPDs) with a multipixel interleaved architecture give the array an excellent spatial PNR capability. However, the signal-to-noise ratio (SNR) of the PNR (SNRPNR) of the array will be degraded with increasing the element number due to the electronic noise in the readout circuit, which limits the PNR resolution as well as the maximum PNR number. In this study, a 16-element interleaved SNSPD array was fabricated, and the PNR capability of the array was investigated and analyzed. By introducing a level comparator circuit (LCC), the SNRPNR of the detector array was improved over a factor of four. In addition, we performed a statistical analysis of the photon number on this SNSPD array with LCC, showing that the LCC method effectively enhances the PNR resolution. Besides, the system timing jitter of the detector was reduced from 90 ps to 72 ps due to the improved electrical SNR.