Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

DC heating in SIS tunnel devices for THz mixing applications.

Pieter Dieleman, T. M. Klapwijk, Sergey Kovtonyuk, H. Vandestadt

Published Jan 1, 1995• 0 citations
OpenAlex

Abstract

Heating effects in Superconductor- Insulator- Superconductor (SIS) tunnel junctions are studied by comparing SIS junctions equipped with niobium and aluminum electrodes. A temperature rise of several K is observed with niobium, which is reduced by an order of magnitude with aluminum. A simple model satisfactorily explains this observation and predicts an increase in the noise temperature of up to 30% at the operating voltage for heterodyne mixing due to this effect.

Related papers

Direct current heating in superconductor–insulator–superconductor tunnel devices for THz mixing applications

Pieter Dieleman, T. M. Klapwijk, Sergey Kovtonyuk +1 more

DC heating effects in superconductor–insulator–superconductor (SIS) tunnel junctions are studied by comparing junctions sandwiched between niobium or aluminum layers. With niobium a temperature rise of several Kelvin is observed, which is reduced by an order of magnitude by using aluminum. A simple model satisfactorily explains this observation and predicts a 30% increase in the subgap current due to the elevated temperature. At the operating voltage for heterodyne mixing the receiver noise temperature increases by only 2%.

Applied Physics Letters•Jul 15, 1996•16 citations

The Influence of LO Power Heating of the Tunnel Junction on the Performance of THz SIS Mixers

Alessandro Traini, Boon-Kok Tan, John Garrett +6 more

We describe the performance of a superconductor- insulator-superconductor (SIS) mixer operating in the frequency range of 780-950 GHz. Unlike most SIS mixers, the tunnel junction employs two different superconductors, a niobium nitride top and a niobium bottom electrode sandwiching an aluminum nitride barrier layer, fabricated on a niobium titanium nitride ground plane. The mixer was tested in a pulse tube cryostat, with all the optical components, in the signal path, mounted inside the vacuum environment to avoid attenuation of the RF signal as it propagates from the hot/cold loads to the mixer. With this setup, we have measured an RF-corrected noise temperature of ~220 K. In this article, we focus on investigating the influence of local oscillator (LO) power heating on the performance of the terahertz mixer. The increase in the junction's physical temperature can be observed experimentally by noting the suppression of the gap voltage in the pumped current-voltage (I-V ) curve as the LO pumping level is increased. Similar observation has already been reported, and attempts were made to estimate the effective temperature of the device using equations of heat transfer between the mixer chip layers. Here, we present an experimental method of quantifying this effect by recovering the effective temperature of the junction through comparing the pumped I-V curves at different pumping levels and fixed bath temperature, with the unpumped I-V curves obtained at varying bath temperatures. We also estimate, for the first time, the effect of heating on the noise temperature as a function of bath temperature and frequency. We show that for typical experimental parameters, the LO heating can increase the double-sideband receiver noise temperature by as much as 20%, and that in the frequency range of the measurements, the effective temperature of the junction at fixed LO power increases linearly with frequency at a rate of 0.5 K/100 GHz.

IEEE Transactions on Terahertz Science and Technology•Sep 30, 2020•5 citations

Shot noise beyond the Tucker theory in niobium tunnel junction mixers

Pieter Dieleman, T. M. Klapwijk

The electrical and shot-noise characteristics of high-current-density niobium superconductor–insulator–superconductor (SIS) tunnel junctions suitable for heterodyne detection of THz radiation are studied. It is found that a significant part of the current at voltages V<2Δ/e is carried via barrier defects (pinholes). Due to the transport mechanism in these pinholes, the shot noise is considerably increased. The data presented clarify an often-observed discrepancy between measured and expected heterodyne mixer noise temperatures and predict a 25% increase in the receiver noise temperature of Nb SIS heterodyne detectors at 1 THz.

Applied Physics Letters•Mar 30, 1998•15 citations

Different shape normal metal interlayers between niobium based SIS junctions and niobium titanium nitride leads and their influence on the electron temperature

Stefan Selig, M. Westig, Karl Jacobs +1 more

In this paper we demonstrate the reduction of heating in a niobium superconductor-insulator-superconductor (SIS) junction with aluminum-oxide tunnel barrier embedded in a niobium-titanium-nitride circuit. Nonequilibrium quasiparticles which are created due to the Andreev trap at the interface between the niobium and the niobium-titanium-nitride layers are relaxed by inserting a normal-metal conductor of gold between these two layers. In an earlier work we explained the observed relaxation of nonequilibrium quasiparticles due to the geometrically assisted cooling effect. In this paper we investigate this cooling effect in dependence of the normal-metal layer shape and size. We expect that an adapted normal-metal layer is necessary for implementation in practical terahertz SIS heterodyne mixer circuits. We observe in DC-measurements of a large number of devices a clear relation between the volume of the gold layer and the effective electron temperature in the device. Our central finding is that the shape of the gold layer does not influence the cooling provided that the volume is sufficient.

Journal of Physics Conference Series•May 12, 2014•1 citation

Improved Nb SIS devices for heterodyne mixers between 700 GHz and 1.3 THz with NbTiN transmission lines using a normal metal energy relaxation layer

M. Westig, S. Selig, K. Jacobs +2 more

In this paper, we demonstrate experimentally the implementation of a niobium-trilayer junction with an aluminum-oxide tunnel barrier, embedded in a high-gap superconducting niobium-titanium-nitride circuit. Previously reported heating by quasiparticle trapping is removed by inserting a normal metal layer of gold between the niobium junction and the niobium-titanium-nitride layer. We analyze in dc-characterization measurements the cooling of the nonequilibrium quasiparticles in various device geometries having different gold layer thickness and shape. Our work is concluded with remarks for future heterodyne mixer experiments using our device technology.

arXiv:1306.6797•Journal of Applied Physics•Sep 24, 2013•11 citations

Quasiparticle heterodyne mixing in SIS tunnel junctions

P. L. Richards, T. M. Shen, R. Harris +1 more

The rapid onset of quasiparitcle tunneling current in superconductor-insulator-superconductor (Josephson) junctions at voltages above 2Δ/e is being used for millimeter-wave heterodyne mixing. Junctions with a 2-μm diameter and RN=50 Ω have little capacitive shunting at the signal frequency of 36 GHz. Because there is no series resistance, residual capacitance can be tuned out. Double sideband conversion efficiencies of 0.32 and mixer noise temperatures as low as TM⩽7 K=4hν/k have been observed. The results are compared with shot-noise-limited mixer theory. Photon-assisted tunneling effects are seen which indicate the approach to photon-noise-limited operation.

Applied Physics Letters•Mar 1, 1979•164 citations
Heating effects in Superconductor- Insulator- Superconductor (SIS) tunnel junctions are studied by comparing SIS junctions equipped with niobium and aluminum electrodes. A temperature rise of several K is observed with niobium, which is reduced by an order of magnitude with aluminum. A simple model satisfactorily explains this observation and predicts an increase in the noise temperature of up to 30% at the operating voltage for heterodyne mixing due to this effect.
DC heating effects in superconductor–insulator–superconductor (SIS) tunnel junctions are studied by comparing junctions sandwiched between niobium or aluminum layers. With niobium a temperature rise of several Kelvin is observed, which is reduced by an order of magnitude by using aluminum. A simple model satisfactorily explains this observation and predicts a 30% increase in the subgap current due to the elevated temperature. At the operating voltage for heterodyne mixing the receiver noise temperature increases by only 2%.
We describe the performance of a superconductor- insulator-superconductor (SIS) mixer operating in the frequency range of 780-950 GHz. Unlike most SIS mixers, the tunnel junction employs two different superconductors, a niobium nitride top and a niobium bottom electrode sandwiching an aluminum nitride barrier layer, fabricated on a niobium titanium nitride ground plane. The mixer was tested in a pulse tube cryostat, with all the optical components, in the signal path, mounted inside the vacuum environment to avoid attenuation of the RF signal as it propagates from the hot/cold loads to the mixer. With this setup, we have measured an RF-corrected noise temperature of ~220 K. In this article, we focus on investigating the influence of local oscillator (LO) power heating on the performance of the terahertz mixer. The increase in the junction's physical temperature can be observed experimentally by noting the suppression of the gap voltage in the pumped current-voltage (I-V ) curve as the LO pumping level is increased. Similar observation has already been reported, and attempts were made to estimate the effective temperature of the device using equations of heat transfer between the mixer chip layers. Here, we present an experimental method of quantifying this effect by recovering the effective temperature of the junction through comparing the pumped I-V curves at different pumping levels and fixed bath temperature, with the unpumped I-V curves obtained at varying bath temperatures. We also estimate, for the first time, the effect of heating on the noise temperature as a function of bath temperature and frequency. We show that for typical experimental parameters, the LO heating can increase the double-sideband receiver noise temperature by as much as 20%, and that in the frequency range of the measurements, the effective temperature of the junction at fixed LO power increases linearly with frequency at a rate of 0.5 K/100 GHz.
The electrical and shot-noise characteristics of high-current-density niobium superconductor–insulator–superconductor (SIS) tunnel junctions suitable for heterodyne detection of THz radiation are studied. It is found that a significant part of the current at voltages V<2Δ/e is carried via barrier defects (pinholes). Due to the transport mechanism in these pinholes, the shot noise is considerably increased. The data presented clarify an often-observed discrepancy between measured and expected heterodyne mixer noise temperatures and predict a 25% increase in the receiver noise temperature of Nb SIS heterodyne detectors at 1 THz.
In this paper we demonstrate the reduction of heating in a niobium superconductor-insulator-superconductor (SIS) junction with aluminum-oxide tunnel barrier embedded in a niobium-titanium-nitride circuit. Nonequilibrium quasiparticles which are created due to the Andreev trap at the interface between the niobium and the niobium-titanium-nitride layers are relaxed by inserting a normal-metal conductor of gold between these two layers. In an earlier work we explained the observed relaxation of nonequilibrium quasiparticles due to the geometrically assisted cooling effect. In this paper we investigate this cooling effect in dependence of the normal-metal layer shape and size. We expect that an adapted normal-metal layer is necessary for implementation in practical terahertz SIS heterodyne mixer circuits. We observe in DC-measurements of a large number of devices a clear relation between the volume of the gold layer and the effective electron temperature in the device. Our central finding is that the shape of the gold layer does not influence the cooling provided that the volume is sufficient.
In this paper, we demonstrate experimentally the implementation of a niobium-trilayer junction with an aluminum-oxide tunnel barrier, embedded in a high-gap superconducting niobium-titanium-nitride circuit. Previously reported heating by quasiparticle trapping is removed by inserting a normal metal layer of gold between the niobium junction and the niobium-titanium-nitride layer. We analyze in dc-characterization measurements the cooling of the nonequilibrium quasiparticles in various device geometries having different gold layer thickness and shape. Our work is concluded with remarks for future heterodyne mixer experiments using our device technology.
The rapid onset of quasiparitcle tunneling current in superconductor-insulator-superconductor (Josephson) junctions at voltages above 2Δ/e is being used for millimeter-wave heterodyne mixing. Junctions with a 2-μm diameter and RN=50 Ω have little capacitive shunting at the signal frequency of 36 GHz. Because there is no series resistance, residual capacitance can be tuned out. Double sideband conversion efficiencies of 0.32 and mixer noise temperatures as low as TM⩽7 K=4hν/k have been observed. The results are compared with shot-noise-limited mixer theory. Photon-assisted tunneling effects are seen which indicate the approach to photon-noise-limited operation.