We present a metrological technique which, without discarding of data, resembles a larger anomalous amplification than weak-value-amplification (WVA). The protocol surpasses WVA techniques by amplifying an almost-balanced homodyne signal.
We experimentally realize a great precision enhancement in the small-tilt measurement by using a Sagnac interferometer and balanced homodyne detection (BHD) of high-order optical modes, together with the weak-value amplification (WVA) technique. Smaller minimum measurable tilt and higher signal-to-noise ratio can be obtained by using BHD, compared with the split detection. The precision of 3.8 nrad can be obtained under our present experimental condition. It is shown that combining WVA technique and BHD can strengthen each other's advantages and can behave better for some special application scenarios, such as extremely weak output, wider measurement bandwidth, etc. Moreover, the precision can be further enhanced by experimental parameter optimization.
We present a parameter estimation technique based on performing joint measurements of a weak interaction away from the weak-value-amplification approximation. Two detectors are used to collect full statistics of the correlations between two weakly entangled degrees of freedom. Without discarding of data, the protocol resembles the anomalous amplification of an imaginary-weak-value-like response. The amplification is induced in the difference signal of both detectors allowing robustness to different sources of technical noise, and offering in addition the advantages of balanced signals for precision metrology. All of the Fisher information about the parameter of interest is collected. A tunable phase controls the strength of the amplification response. We experimentally demonstrate the proposed technique by measuring polarization rotations in a linearly polarized laser pulse. We show that in the presence of technical noise the effective sensitivity and precision of a split detector is increased when compared to a conventional continuous-wave balanced detection technique.
We propose precision measurements of ultra-small angular velocities of a mirror within a modified Sagnac interferometer, where the counter-propagating beams are spatially separated, using the recently proposed technique of almost-balanced weak values amplification (ABWV) [Phys. Rev. Lett.116, 100803 (2016)PRLTAO0031-900710.1103/PhysRevLett.116.100803]. The separation between the two beams provides additional amplification with respect to using collinear beams in a Sagnac interferometer. Within the same setup, the weak-value amplification technique is also performed for comparison. Much higher amplification factors can be obtained using the almost-balanced weak values technique, with the best one achieved in our experiments being as high as 1.2×107. In addition, the amplification factor monotonically increases with decreasing of the post-selection phase for the ABWV case in our experiments, which is not the case for weak-value amplification (WVA) at small post-selection phases. Both techniques consist of measuring the angular velocity. The sensitivity of the ABWV technique is ∼38 nrad/s per averaged pulse for a repetition rate of 1 Hz and ∼33 nrad/s per averaged pulse for the WVA technique.