Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Conference on Lasers and Electro-Optics

Interferometric signal retrieval in single-beam coherent anti-Stokes Raman scattering

Yujie Shen, Dmitri V. Voronine, Alexei V. Sokolov, Marlan O. Scully

Published Jan 1, 2016• 0 citations
Publisher

Abstract

Interferometric retrieval of coherent anti-Stokes Raman scattering signal through pulse shaper is demonstrated. The method allows for fast acquisition, and is beneficial in detecting broad Raman structure that has short coherence lifetime.
DOI
10.1364/cleo_si.2016.sm4i.7

Related papers

Coherent Anti-Stokes Raman scattering in optically active medium

Tuguldur Begzjav, Marlan O. Scully, G. S. Agarwal

Early theoretical works on coherent anti-Stokes Raman scattering in optically active medium consider only heterodyne signal and subsequently, fourth- and fifth-rank tensor averages have been used. In this work, we presented a full signal expression of coherent anti-Stokes Raman scattering in optically active medium with the help of eighth- and ninth-rank tensor averaging for simplest experimental configuration namely, measurements of post-selected circularly polarized components of scattered anti-Stokes field in the presence of three incident laser beams all linearly polarized along the same axis.

arXiv:1901.00459•Jan 2, 2019•0 citations

Interferometric switching of coherent anti-Stokes Raman scattering signals in microscopy

Alexei Nikolaenko, Vishnu Vardhan Krishnamachari, Eric Olaf Potma

Coherent anti-Stokes Raman scattering (CARS) interferometry is used to deplete the anti-Stokes radiation emerging from a tightly focused spot. Near-to-complete depletion of the anti-Stokes radiation is obtained when a phase-controlled local oscillator field at the anti-Stokes frequency is out of phase with the induced CARS field in the focal volume. Unlike in traditional interferometry, this depleted energy is not spatially redistributed. A theoretical analysis shows that the energy loss in the anti-Stokes channel is accompanied by an energy gain in the pump and Stokes channels. Interferometric switching of anti-Stokes radiation may offer a route toward developing high-resolution CARS microscopy.

Physical Review A•Jan 27, 2009•26 citations

Broadband spectral interferometric polarisation coherent anti-Stokes Raman scattering

Priyank Shah

•Mar 1, 2021•0 citations

Coherent anti-Stokes Raman Scattering Lidar Using Slow Light: A Theoretical Study

Li Gong, Haifeng Wang

We theoretically investigate a scheme in which backward coherent anti-Stokes Raman scattering (CARS) is significantly enhanced by using slow light. Specifically, we reduce the group velocity of the Stokes excitation pulse by introducing a coupling laser that causes electromagnetically induced transparency (EIT). When the Stokes pulse has a spatial length shorter than the CARS wavelength, the backward CARS emission is significantly enhanced. We also investigated the possibility of applying this scheme as a CARS lidar with O2 or N2 as the EIT medium. We found that if nanosecond laser with large pulse energy (>1 J) and a telescope with large aperture (~10 m) are equipped in the lidar system, a CARS lidar could become much more sensitive than a spontaneous Raman lidar.

arXiv:1701.00207•Jan 1, 2017•1 citation

Coherent versus incoherent Raman scattering: molecular coherence excitation and measurement

Dmitry Pestov, Gombojav O. Ariunbold, Xi Wang +4 more

We present a comparative analysis of spontaneous and coherent Raman scattering on pyridine. The instantaneous excitation of the molecular coherence is done by a pair of ultrashort preparation pulses. Then, a long narrowband probe pulse is scattered off the molecular vibrations. The described hybrid technique allows for the single-shot acquisition of a background-free coherent Raman spectrum within the excitation band and its straightforward comparison with the spontaneous Raman measurements, performed in the same setup. We report a 10(5)-fold increase in the efficiency of the Raman scattering process due to the broadband pump-Stokes preparation. The coherence magnitude (approximately 0.5x10(-3)) is inferred experimentally, without a priori knowledge about the molecular structure.

Optics Letters•Jun 6, 2007•66 citations

Rapid acquisition and storage of broadband single-pulse coherent anti-Stokes Raman transient phenomena (A)

David Klick, Kenneth A. Marko, L. Rimai

Journal of the Optical Society of America A•Jan 1, 1983•0 citations
Early theoretical works on coherent anti-Stokes Raman scattering in optically active medium consider only heterodyne signal and subsequently, fourth- and fifth-rank tensor averages have been used. In this work, we presented a full signal expression of coherent anti-Stokes Raman scattering in optically active medium with the help of eighth- and ninth-rank tensor averaging for simplest experimental configuration namely, measurements of post-selected circularly polarized components of scattered anti-Stokes field in the presence of three incident laser beams all linearly polarized along the same axis.
Coherent anti-Stokes Raman scattering (CARS) interferometry is used to deplete the anti-Stokes radiation emerging from a tightly focused spot. Near-to-complete depletion of the anti-Stokes radiation is obtained when a phase-controlled local oscillator field at the anti-Stokes frequency is out of phase with the induced CARS field in the focal volume. Unlike in traditional interferometry, this depleted energy is not spatially redistributed. A theoretical analysis shows that the energy loss in the anti-Stokes channel is accompanied by an energy gain in the pump and Stokes channels. Interferometric switching of anti-Stokes radiation may offer a route toward developing high-resolution CARS microscopy.
We theoretically investigate a scheme in which backward coherent anti-Stokes Raman scattering (CARS) is significantly enhanced by using slow light. Specifically, we reduce the group velocity of the Stokes excitation pulse by introducing a coupling laser that causes electromagnetically induced transparency (EIT). When the Stokes pulse has a spatial length shorter than the CARS wavelength, the backward CARS emission is significantly enhanced. We also investigated the possibility of applying this scheme as a CARS lidar with O2 or N2 as the EIT medium. We found that if nanosecond laser with large pulse energy (>1 J) and a telescope with large aperture (~10 m) are equipped in the lidar system, a CARS lidar could become much more sensitive than a spontaneous Raman lidar.
We present a comparative analysis of spontaneous and coherent Raman scattering on pyridine. The instantaneous excitation of the molecular coherence is done by a pair of ultrashort preparation pulses. Then, a long narrowband probe pulse is scattered off the molecular vibrations. The described hybrid technique allows for the single-shot acquisition of a background-free coherent Raman spectrum within the excitation band and its straightforward comparison with the spontaneous Raman measurements, performed in the same setup. We report a 10(5)-fold increase in the efficiency of the Raman scattering process due to the broadband pump-Stokes preparation. The coherence magnitude (approximately 0.5x10(-3)) is inferred experimentally, without a priori knowledge about the molecular structure.