Ghost imaging is an imaging technique in which the image of an object is revealed only in the correlation measurement between two beams of light, whereas the individual measurements contain no imaging information. Normally, the resolution of the image, which even exceeds the Rayleigh limit, is shown to be related to the transverse coherent length (lc) of the speckle pattern. In this Letter, we demonstrate experimentally that the speckle size can be compressed by a coherent population trapping (CPT) process in atom vapor, and the resolution of GI can be greatly enhanced by the CPT process. The technique we exploit is quite efficient and robust, and it may be useful in the field of quantum and classical two-photon imaging, all-optical image processing, and quantum communication.
Ghost imaging is an imaging technique in which the image of an object is revealed only in the correlation measurement between two beams of light, whereas the individual measurements contain no imaging information. Normally, the resolution of the image, which even exceeds the Rayleigh limit, is shown to be related to the transverse coherent length (lc) of the speckle pattern. In this Letter, we demonstrate experimentally that the speckle size can be compressed by a coherent population trapping (CPT) process in atom vapor, and the resolution of GI can be greatly enhanced by the CPT process. The technique we exploit is quite efficient and robust, and it may be useful in the field of quantum and classical two-photon imaging, all-optical image processing, and quantum communication.
Ghost imaging is an imaging technique in which the image of an object is revealed only in the correlation measurement between two beams of light, whereas the individual measurements contain no imaging information. Here, we experimentally demonstrate storage and retrieval of ghost images in hot atomic rubidium vapor. Since ghost imaging requires (quantum or classical) multimode spatial correlation between two beams of light, our experiment shows that the spatially multimode correlation, a second-order correlation property of light, can indeed be preserved during the storage-retrieval process. Our work, thus, opens up new possibilities for quantum and classical two-photon imaging, all-optical image processing, and quantum communication.
Quantum ghost imaging harnesses entangled photon pairs to form images using light that never directly interacts with the object. Conventional approaches rely on pixelated detectors or spatial masks, where the resolution is fundamentally limited by the pixel size and thus bounded by the Rayleigh criterion. In this work, we present a modal approach that replaces pixel-based detection with measurements in a basis of structured modes. By reconstructing images through tailored spatial modes, we decouple resolution from the physical limitations of detectors and instead tie it to the system’s optical precision and computational control. We demonstrate that even non-orthogonal modal sets can achieve high fidelity image reconstruction by exploiting modal sparsity, significantly reducing the number of required measurements. Using phase-only approximations of Hermite-Gaussian modes, we avoid the loss associated with complex amplitude modulation while retaining high reconstruction fidelity. The result is a high-resolution, high-efficiency quantum ghost imaging technique powered by structured light, opening new possibilities for photon-efficient imaging in low-light and quantum-limited regimes, such as biological microscopy and remote sensing.
Abstract Recent years have seen vast progress in image modulation based on atomic media, with potential applications in both classical optical imaging and quantum imaging regions. However, there have been few investigations of how thermal light images interact with an electromagnetically induced transparent medium. In this letter, we experimentally demonstrate pseudo-thermal light modulation on coherent population trapping conditions in 87Rb vapor. By introducing the Laguerre-Gaussian beam as the control beam and the encoded speckle as the probe beam, we obtained sharper speckle patterns after the atom cell compared with that in free space. The spatially modulated thermal light was then used to enhance the image resolution in ghost imaging of which the resolution was enhanced by factor 3, since the ghost image resolution is heavily reliant on the speckle’s transverse coherent length. Our results are promising for potential applications in high resolution ghost imaging and image metrology, image processing and biomedical imaging.
Ghost imaging allows one to obtain information on an object from the spatial correlation function between photons propagating through or reflected from the object and photons of the reference arm. In this case, detection in the object arm is performed over the entire aperture of the beam and, therefore, it does not give information on the object. The reference beam does not interact with the object, but is recorded with a scanning point detector or a CCD array permitting the measurement of the spatial correlation function of photons in two arms. The use of multimode entangled quantum light beams by illuminating the object by one beam and orienting other beams to reference arms makes it possible to obtain simultaneously several ghost images (GIs). Cross correlations of multiplexed GIs (MGIs) are determined by eighth-order field correlation functions. A special algorithm is developed for calculating higher-order correlations of Bose operators. The presence of GI cross correlations is used for improving the quality of the reconstructed object’s image by their processing using the measurement reduction method. An example of the computer simulation of the image reconstruction by MGIs formed in the field of four-frequency entangled quantum states is considered. It is found that in this case the reduced GI has a signal-to-noise ratio several times higher than that of GIs.
Correlated-photon imaging, popularly known as ghost imaging, is a technique whereby an image is formed from light that has never interacted with the object. In ghost imaging experiments two correlated light fields are produced. One of these fields illuminates the object, and the other field is measured by a spatially resolving detector. In the quantum regime, these correlated light fields are produced by entangled photons created by spontaneous parametric down-conversion. To date, all correlated-photon ghost-imaging experiments have scanned a single-pixel detector through the field of view to obtain the spatial information. However, scanning leads to a poor sampling efficiency, which scales inversely with the number of pixels, N, in the image. In this work we overcome this limitation by using a time-gated camera to record the single-photon events across the full scene. We obtain high-contrast images, 90%, in either the image plane or the far-field of the photon pair source, taking advantage of the EPR-like correlations in position and momentum of the photon pairs. Our images contain a large number of modes, >500, creating opportunities in low-light-level imaging and in quantum information processing.
The process of image recording is arguably one of the most prevalent technology in modern society and continues to inspire vast swathes of research due to its widespread applications spanning military, medical and consumer spheres. The danger present in a field so broad is that separate niches of research can become isolated with critical advancements struggling to traverse the gulfs between. Unifying the field is the omnipresent drive to acquire an ever increasing quality of images at the lowest possible cost, a goal which warrants continual fundamental research. Quantum entanglement exhibits many intriguing characteristics which make it a suitable tool for such fundamental investigations. The process of spontaneous parametric down- conversion has offered a yet unbeaten strength of photon correlations with the quantum nature of their production providing a reliable and controllable source of single-photons. Arising from these attributes is the technique known as ghost imaging. Though now known to be classically possible, the strength of entanglement generated correlations is yet to be surpassed. This thesis implemented this technique in tandem with the cutting edge detector technology in order to probe the fundamentals of image formation. This form of imaging allowed us to subject an object to a known number of photons whilst acquiring structural information from spatially separate, correlated photons which never interact with the object. The strength of the produced correlations allow us to acquire low background, high resolution images with far less light than traditional techniques and affords many novel benefits. The possibility of incorporating this technique with pre-existent regimes allowed me to draw from advancements made across the landscape of imaging research. Although referred to as “quantum ghost imaging” throughout this work, it should be noted that the intrinsic quantum nature of the correlations was not directly relied upon but provided an ideal source of strongly correlated photons. In order to determine the limits of a traditional imaging system this thesis first sought to answer the question: “can an image of an object be reconstructed from fewer photons than ii pixels in the image?” In chapter 3 I approached this from the perspective of compression, which minimises redundant information within a signal. This lead to the development of an imaging regime capable of imaging with far fewer photons than pixels in the image. By employing assumptions about the sparsity of natural images I was able to reconstruct an image of a biological sample containing an average of less than one photon per image pixel. Having reduced the number of photons necessary to form an image I then considered alternative methods for reducing the optical energy impinging on a sample. I sought to answer the question: “can non-degenerate ghost imaging reduce the optical energy impinged upon an object during imaging”. The photons produced in SPDC need not be of similar wavelengths, however may be chosen far from degeneracy, i.e. non-degenerate. In Chapter 4 I presented a ghost imaging system which illuminated the object with infrared light whilst recording the structural information via entangled visible photons. This allowed for objects opaque to visible light to be imaged in high quality without the need for a spatially resolving infrared detector, the state of the art of which lags behind their silicon based visible counterparts. I presented the systems capabilities by imaging objects which were etched into a gold substrate layered on to silicon, both of which are opaque to visible light. Not only did a reduction in energy deposition arise from the lower energy probe wavelength but applying the reconstruction techniques from the previous chapter brought that down to as low as ≈16 nJcm−2s−1. Seeking to expand the repertoire of applications, the low-light capabilities of my ghost imaging were applied to the technique of phase-contrast microscopy in chapter 5. Typically applied to translucent objects, phase-contrast imaging transfers phase information, i.e. the refractive index changed within the object, into an intensity distribution through the use of a phase-filter. In many of these applications the objects tend to be biological in nature, where high optical exposure can result in bleaching or damage. By applying the phase-filter non- locally, i.e. to the photons correlated to those probing the object, I acquired edge-enhanced images of a phase object whilst illuminating with significantly fewer photons than standard phase-contrast techniques. Having displayed the broad applicability of our low-light ghost imaging system, I then sought to determine the optical resolution in chapter 6. The resolution limits of ghost imaging are not clear at first glance owing to the resolutions dependence upon the strength of spatial correlations. As the length over which the spatial correlations are produced can be brought below the standard diffraction limit, it would seem the resolution of the system could be brought similarly low. To clarify this I artificially restricted the number of spatial modes in each of the correlated beams to uncover the physically realisable resolution. I show that although the resolution of a ghost imaging system to be fundamentally determined by the strength of the correlations, this can never be reached due to the inherent limitations of the intervening imaging system.