We have used an ultralow threshold continuous-wave optical parametric oscillator (OPO) to reduce the quantum fluctuations of the reflected pump beam below the shot noise limit. The OPO consisted of a triply resonant cavity containing a periodically poled lithium niobate crystal pumped by a Nd:YAG (yttrium aluminum garnets) laser and giving signal and idler wavelengths close to $2.12\ensuremath{\mu}\mathrm{m}$ and a threshold as low as $300\ensuremath{\mu}\mathrm{W}.$ We detected the quantum fluctuations of the pump beam reflected by the OPO using a slightly modified homodyne detection technique. The measured noise reduction was
30 (inferred noise reduction at the output of the OPO
38A 106μm all-solid-state single frequency Nd∶YVO4 laser was explored to pump a triply resonant optical parametrie oscillator(OPO) based on the periodically poled lithium niobate. When the OPO operated near degeneracy, the amplitude fluctuation correlation of the signal and idler modes was observed as their wavelengths were separated about 200nm. The measured squeezing is 04dB. The amplitude fluctuation correlation existed in a range of 17nm as we tuned the wavelengths of the signal and idler by change the crystal temperature.
A cw optical parametric oscillator (OPO) operated above threshold is of particular interest in current squeezing experiments. Quadrature squeezing in the signal and idler modes and in the pump mode is predicted. Intensity squeezing in the difference intensity of the signal and idler is predicted and has recently been observed.1 We have built a doubly resonant cw OPO with a magnesium oxide- doped lithium niobate crystal that is single-pass-pumped with the 530.9-nm line of a kryptonion laser. Mode hopping instability near degeneracy puts stringent requirements on the frequency stability of the pump laser and the mechanical stability of the OPO cavity. We have oberved such instability near degeneracy and determined the stability requirements for this OPO. Stable operation can be obtained as the OPO is operated away from degeneracy but at a higher threshold. Classically the single-pass pump output is predicted to be clamped at the threshold value so that the OPO in this configuration acts as a pump power limiter. Quantum mechanically, we have found that the pump intensity noise is enhanced. Measurements on the pump intensity noise spectrum in this particular configuration have been made and compared to our theoretical predictions.
A single-frequency optical parametric oscillator (OPO) operating in the wavelength range around 2 µm is reported. The OPO comprises a periodically poled LiNbO 3 (PPLN) crystal for quasi-phase matching and a four-mirror ring-cavity resonant to the signal. The OPO signal and idler are tuned from 1.89 to 2.05 µm and from 2.21 to 2.42 µm, respectively, by changing the crystal temperature. Output powers in excess of 2 W are demonstrated at a pump power of 9 W for both the signal and idler over all of the respective tuning ranges. A detailed characterization of the intensity and frequency noise is presented. The OPO exhibits an integrated intensity noise below 0.1% and a linewidth of ∼58 kHz for an observation time of 1 ms. The reported performance makes this source an ideal candidate for the generation of squeezed light around 2 µm via cascaded second-harmonic generation (SHG) and parametric downconversion (PDC).
A quasi- phase-matched optical parametric oscillator(QPM OPO)consisting of a periodically poled LiNbO3(PPLN) crystal is pumped by an all-solid state single frequency Nd:YVO4 laser. The triple resonance of the pump mode and two subharmonic modes with near- degenerate frequencies are experimentally demonstrated by means of precision temperature control of the crystal. The threshold pump power is only 1.2mW. The quadrature phase noise squeezing of the pump field reflected from the OPO up to 1.1dB is observed at the pump power of 2.8 times of the oscillation threshold. The numerically calculated result is in good agreement with the experimentally measured data.
Quantum noise limits the sensitivity of optical measurements, but squeezed states of light enable quantum-enhanced metrology, sensing, and information processing. Most on-chip squeezed-light sources rely on Kerr (
χ(3)) nonlinearities, remain limited by pump power and excess loss constraints. Quadratic (
χ(2)) platforms instead provide stronger parametric interactions, lower pump power requirements, and greater spectral engineering flexibility. Here, we demonstrate strong, broadband squeezed-light generation on a thin-film lithium niobate (TFLN) photonic chip using a dual-resonant optical parametric amplifier implemented in a single periodically poled LN (PPLN) microresonator. Near-full-depth domain inversion is achieved simultaneously with highly over-coupled resonances, exhibiting escape efficiencies exceeding 90% and intrinsic quality factors above 2.5 million in a 0.6 mm
2 X-cut TF-PPLN resonator, enabling efficient squeezing at 1587 nm when pumped at 793.5 nm. Operating in the continuous-wave regime, we directly measure -0.81 dB of squeezing below the shot-noise limit with a pump power of 27 mW, together with +4.29 dB of anti-squeezing. From these measurements, we infer an on-chip squeezing level of -7.52 dB
± 0.22 dB (95% confidence interval: [-7.96,-7.10] dB), and an on-chip anti-squeezing level of +9.62 dB
± 0.25 dB. We demonstrate single-mode squeezing at degeneracy with a squeezed-light spectrum exceeding 10.3 THz. This work reports the highest squeezing ratio among integrated
χ(2) cavity platforms and the first quasi-phase matched, fully resonant
χ(2) cavity squeezer on chip, establishing a scalable route to fully integrated power-efficient squeezed-light sources for quantum-enhanced sensing and metrology.