URSI International Symposium on Electromagnetic Theory

Study of field misalignment in a cavity used for atomic clock applications

Anton E. Ivanov, C. Affolderbach, G. Mileti, Anja K. Skrivervik

Published Aug 1, 2016• 1 citation
Publisher

Abstract

In vapor cell atomic clocks the atom-field interaction is typically obtained inside a microwave cavity resonator in which the microwave driving field together with a static magnetic field and an optical field are applied to excite the atoms. These fields are generally well-controlled, mutually aligned to a common quantization axis. Since the exploited atomic transition is sensitive to any potential axis misalignment, the performance of the clock can also be affected. We study the effect of such misalignment for the case of a cylindrical cavity used in vapor-cell atomic clocks, taking into account the misalignments of the optical detection field and the static magnetic field required for the atomic transition. Both the geometry of the cavity and the factors contributing to losses can play role in the degradation of the signal and are taken into account in the misalignment problem discussed.

DOI
10.1109/ursi-emts.2016.7571382

Related papers

Phase-shift in vapor cell and compact cold-atom frequency standards

Aldo Godone, Salvatore Micalizio

We report on a theoretical analysis of the phase-shift in compact atomic clocks working either with cold or thermal atoms. It is well known that in a microwave cavity with electromagnetic losses, a traveling wave adds to the standing wave of a given resonant mode. We calculate the spatial varying phase related to this travelling wave for two geometries of interest in clock applications, the cylindrical cavity and the spherical cavity. Due to their motion, the atoms probe different regions of the cavity and then experience different phases of the interrogating microwave field. We show that this combination of atomic motion and spatial changing phase results in a phase-shift of the clock frequency, well known in primary frequency standards, that can affect the metrological performances also of vapor cell and compact cold-atom clocks. In the latter case, we evaluate the phase-shift for a space clock and a ground clock.

arXiv:1705.01379•May 3, 2017•0 citations

Study of additive manufactured microwave cavities for pulsed optically pumped atomic clock applications

C. Affolderbach, William Moreno, A. E. Ivanov +5 more

Additive manufacturing (AM) of passive microwave components is of high interest for the cost-effective and rapid prototyping or manufacture of devices with complex geometries. Here, we present an experimental study on the properties of recently demonstrated microwave resonator cavities manufactured by AM, in view of their applications to high-performance compact atomic clocks. The microwave cavities employ a loop-gap geometry using six electrodes. The critical electrode structures were manufactured monolithically using two different approaches: Stereolithography (SLA) of a polymer followed by metal coating and Selective Laser Melting (SLM) of aluminum. The tested microwave cavities show the desired TE011-like resonant mode at the Rb clock frequency of ≈6.835 GHz, with a microwave magnetic field highly parallel to the quantization axis across the vapor cell. When operated in an atomic clock setup, the measured atomic Rabi oscillations are comparable to those observed for conventionally manufactured cavities and indicate a good uniformity of the field amplitude across the vapor cell. Employing a time-domain Ramsey scheme on one of the SLA cavities, high-contrast (34%) Ramsey fringes are observed for the Rb clock transition, along with a narrow (166 Hz linewidth) central fringe. The measured clock stability of 2.2 × 10−13 τ−1/2 up to the integration time of 30 s is comparable to the current state-of-the-art stabilities of compact vapor-cell clocks based on conventional microwave cavities and thus demonstrates the feasibility of the approach.

Applied Physics Letters•Mar 12, 2018•22 citations

Loaded Microwave Cavity for Compact Vapor-Cell Clocks

Michele Gozzelino, Salvatore Micalizio, Claudio Eligio Calosso +3 more

Vapor-cell devices based on microwave interrogation provide a stable frequency reference with a compact and robust setup. Further miniaturization must focus on optimizing the physics package, containing the microwave cavity and atomic reservoir. In this article, we present a compact cavity-cell assembly based on a dielectric-loaded cylindrical resonator. The loaded cavity resonating at 6.83 GHz has an external volume of only 35 cm3and accommodates a vapor cell with 0.9-cm3inner volume. The proposed design aims at strongly reducing the core of the atomic clock, maintaining, at the same time, high-performing short-term stability ($\sigma _{y}{(}\tau {)} \leq {5}\times {10}^{-{13}} \,\tau ^{-{1}/{2}}$ standard Allan deviation). The proposed structure is characterized in terms of microwave field uniformity and atom-field coupling with the aid of finite-element calculations. The thermal sensitivity is also analyzed and experimentally characterized. We present preliminary spectroscopy results by integrating the compact cavity within a rubidium clock setup based on the pulsed optically pumping technique. The obtained clock signals are compatible with the targeted performances. The loaded-cavity approach is, thus, a viable design option for miniaturized microwave clocks.

arXiv:2005.10159•IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control•Jul 23, 2020•9 citations

Study of the Misalignment Between Electromagnetic Fields Interacting with Rb Atoms in a Cavity with Losses

А. Е. Иванов

In this study we investigate the impact of misalignment of the static and/or microwave magnetic fields from the laser propagation direction. Our analysis is suitable to reveal how the geometry of the cavity and the losses influence the resonance transitions and is relevant in line with newly developed cavity characterization techniques based on field imaging.

European Frequency and Time Forum•Jan 1, 2016•0 citations

Distortion of Rabi oscillations in a compact cold-atom clock

Xinchuan Ouyang, Bowen Yang, Qingqing Hu +4 more

We report on experimental measurements and theoretical calculations of Rabi oscillation distortion during rubidium clock transition in a compact cold-atom clock. The distortion of the Rabi oscillations of the clock transition caused by the magnetically sensitive transitions between magnetic sublevels is related to the duration and amplitude of the microwave pulse, the density distribution of cold atoms, and the biased magnetic field inside the microwave cavity. The theoretical calculations agreed well with the experimental results. The Rabi oscillation measurements are beneficial for determining the optimal parameters of a cold-atom clock and identifying the uniformity of the microwave field inside the cavity. This measurement can be extended to the atomic fountain clock and the vapor-cell atomic clock.

Physical Review A•Apr 26, 2021•4 citations

Quantum Applications of an Atomic Ensemble Inside a Laser Cavity

R. Shuker, Andrei Ben-Amar Baranga, David Levron +2 more

Many quantum device signals are proportional to the number of the participating atoms that take part in the detection devices. Among these are optical magnetometers, atomic clocks, quantum communications and atom interferometers. One way to enhance the signal-to-noise ratio is to introduce atom entanglement that increases the signal in a super-radiant-like effect. A coherent em field inside a laser cavity is suggested to achieve atoms’ correlation/entanglement. This may also play an important role in the basic quantum arena of many-body physics. An initial novel experiment to test the realization of atoms’ correlation is described here. A Cs optical magnetometer is used as a tool to test the operation of a cell-in-cavity laser and its characteristics. A vapor cell is inserted into an elongated external cavity of the pump laser in Littrow configuration. Higher atom polarization and reduced laser linewidth are obtained leading to better magnetometer sensitivity and signal-to-noise ratio. The Larmor frequency changes of the Free Induction Decay of optically pumped Cs atomic polarization in the ambient earth magnetic field at room temperature is measured. Temporal changes in the magnetic field of less than 10 pT/√Hz are measured. The first-order dependence of the magnetic field on temperature and temperature gradients is eliminated, important in many practical applications. Single and gradiometric magnetometer configurations are presented.

Photonics•Jan 2, 2024•0 citations
In vapor cell atomic clocks the atom-field interaction is typically obtained inside a microwave cavity resonator in which the microwave driving field together with a static magnetic field and an optical field are applied to excite the atoms. These fields are generally well-controlled, mutually aligned to a common quantization axis. Since the exploited atomic transition is sensitive to any potential axis misalignment, the performance of the clock can also be affected. We study the effect of such misalignment for the case of a cylindrical cavity used in vapor-cell atomic clocks, taking into account the misalignments of the optical detection field and the static magnetic field required for the atomic transition. Both the geometry of the cavity and the factors contributing to losses can play role in the degradation of the signal and are taken into account in the misalignment problem discussed.
We report on a theoretical analysis of the phase-shift in compact atomic clocks working either with cold or thermal atoms. It is well known that in a microwave cavity with electromagnetic losses, a traveling wave adds to the standing wave of a given resonant mode. We calculate the spatial varying phase related to this travelling wave for two geometries of interest in clock applications, the cylindrical cavity and the spherical cavity. Due to their motion, the atoms probe different regions of the cavity and then experience different phases of the interrogating microwave field. We show that this combination of atomic motion and spatial changing phase results in a phase-shift of the clock frequency, well known in primary frequency standards, that can affect the metrological performances also of vapor cell and compact cold-atom clocks. In the latter case, we evaluate the phase-shift for a space clock and a ground clock.
Additive manufacturing (AM) of passive microwave components is of high interest for the cost-effective and rapid prototyping or manufacture of devices with complex geometries. Here, we present an experimental study on the properties of recently demonstrated microwave resonator cavities manufactured by AM, in view of their applications to high-performance compact atomic clocks. The microwave cavities employ a loop-gap geometry using six electrodes. The critical electrode structures were manufactured monolithically using two different approaches: Stereolithography (SLA) of a polymer followed by metal coating and Selective Laser Melting (SLM) of aluminum. The tested microwave cavities show the desired TE011-like resonant mode at the Rb clock frequency of ≈6.835 GHz, with a microwave magnetic field highly parallel to the quantization axis across the vapor cell. When operated in an atomic clock setup, the measured atomic Rabi oscillations are comparable to those observed for conventionally manufactured cavities and indicate a good uniformity of the field amplitude across the vapor cell. Employing a time-domain Ramsey scheme on one of the SLA cavities, high-contrast (34%) Ramsey fringes are observed for the Rb clock transition, along with a narrow (166 Hz linewidth) central fringe. The measured clock stability of 2.2 × 10−13 τ−1/2 up to the integration time of 30 s is comparable to the current state-of-the-art stabilities of compact vapor-cell clocks based on conventional microwave cavities and thus demonstrates the feasibility of the approach.
Vapor-cell devices based on microwave interrogation provide a stable frequency reference with a compact and robust setup. Further miniaturization must focus on optimizing the physics package, containing the microwave cavity and atomic reservoir. In this article, we present a compact cavity-cell assembly based on a dielectric-loaded cylindrical resonator. The loaded cavity resonating at 6.83 GHz has an external volume of only 35 cm3and accommodates a vapor cell with 0.9-cm3inner volume. The proposed design aims at strongly reducing the core of the atomic clock, maintaining, at the same time, high-performing short-term stability (σy(τ)≤5×10−13 τ−1/2\sigma _{y}{(}\tau {)} \leq {5}\times {10}^{-{13}} \,\tau ^{-{1}/{2}}σy​(τ)≤5×10−13τ−1/2 standard Allan deviation). The proposed structure is characterized in terms of microwave field uniformity and atom-field coupling with the aid of finite-element calculations. The thermal sensitivity is also analyzed and experimentally characterized. We present preliminary spectroscopy results by integrating the compact cavity within a rubidium clock setup based on the pulsed optically pumping technique. The obtained clock signals are compatible with the targeted performances. The loaded-cavity approach is, thus, a viable design option for miniaturized microwave clocks.
We report on experimental measurements and theoretical calculations of Rabi oscillation distortion during rubidium clock transition in a compact cold-atom clock. The distortion of the Rabi oscillations of the clock transition caused by the magnetically sensitive transitions between magnetic sublevels is related to the duration and amplitude of the microwave pulse, the density distribution of cold atoms, and the biased magnetic field inside the microwave cavity. The theoretical calculations agreed well with the experimental results. The Rabi oscillation measurements are beneficial for determining the optimal parameters of a cold-atom clock and identifying the uniformity of the microwave field inside the cavity. This measurement can be extended to the atomic fountain clock and the vapor-cell atomic clock.
Many quantum device signals are proportional to the number of the participating atoms that take part in the detection devices. Among these are optical magnetometers, atomic clocks, quantum communications and atom interferometers. One way to enhance the signal-to-noise ratio is to introduce atom entanglement that increases the signal in a super-radiant-like effect. A coherent em field inside a laser cavity is suggested to achieve atoms’ correlation/entanglement. This may also play an important role in the basic quantum arena of many-body physics. An initial novel experiment to test the realization of atoms’ correlation is described here. A Cs optical magnetometer is used as a tool to test the operation of a cell-in-cavity laser and its characteristics. A vapor cell is inserted into an elongated external cavity of the pump laser in Littrow configuration. Higher atom polarization and reduced laser linewidth are obtained leading to better magnetometer sensitivity and signal-to-noise ratio. The Larmor frequency changes of the Free Induction Decay of optically pumped Cs atomic polarization in the ambient earth magnetic field at room temperature is measured. Temporal changes in the magnetic field of less than 10 pT/√Hz are measured. The first-order dependence of the magnetic field on temperature and temperature gradients is eliminated, important in many practical applications. Single and gradiometric magnetometer configurations are presented.