Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Applied Physics Letters

Demonstration of a high data rate atom interferometer accelerometer.

Hayden McGuinness, Grant W. Biedermann, Akash Rakholia

Published Sep 1, 2011• 0 citations
OpenAlex

Related papers

High Data-Rate Atom Interferometer Accelerometers and Gyroscopes.

Hayden McGuinness, Grant W. Biedermann, Akash Rakholia

•Jul 1, 2012•0 citations

A dual-atom-interferometric gyroscope–accelerometer with simultaneous fringe locking

Huibin Yao, 岳旭光, Wenju Wei +9 more

Dual-atom-interferometer configurations are widely used in gyroscopes and gradiometers to suppress common-mode noise and extract inertial signals with high precision. However, phase coupling between the two interferometers arising from shared Raman laser fields poses a significant challenge to simultaneous fringe locking. Here, we demonstrate a dual-atom-interferometric gyroscope–accelerometer that simultaneously locks both interference fringes at their respective mid-fringe operating points using independent direct digital synthesizer (DDS) channels to control the Raman phase shifts of the two interferometers. The proposed dual-fringe-locking scheme independently stabilizes both interferometers while preserving the common-mode noise rejection inherent to the dual-interferometer configuration. Compared with conventional full-fringe scanning, the scheme enables simultaneous rotation-rate and acceleration measurements with a higher data rate and improved sensitivity in both channels. These results demonstrate the potential of dual-fringe locking for high-precision quantum inertial sensing.

Journal of Physics B Atomic Molecular and Optical Physics•Nov 12, 2026•0 citations

High Data-Rate Atom Interferometry for Dynamic Acceleration and Rotation.

Akash Rakholia, Grant W. Biedermann, Hayden McGuinness

•Jun 1, 2015•0 citations

Atomic References for Measuring Small Accelerations

Lute Maleki, Nan Yu

Accelerometer systems that would combine the best features of both conventional (e.g., mechanical) accelerometers and atom interferometer accelerometers (AIAs) have been proposed. These systems are intended mainly for use in scientific research aboard spacecraft but may also be useful on Earth in special military, geological, and civil-engineering applications. Conventional accelerometers can be sensitive, can have high dynamic range, and can have high frequency response, but they lack accuracy and long-term stability. AIAs have low frequency response, but they offer high sensitivity, and high accuracy for measuring small accelerations. In a system according to the proposal, a conventional accelerometer would be used to perform short-term measurements of higher-frequency components of acceleration, while an AIA would be used to provide consistent calibration of, and correction of errors in, the measurements of the conventional accelerometer in the lower-frequency range over the long term. A brief description of an AIA is prerequisite to a meaningful description of a system according to the proposal. An AIA includes a retroreflector next to one end of a cell that contains a cold cloud of atoms in an ultrahigh vacuum. The atoms in the cloud are in free fall. The retroreflector is mounted on the object, the acceleration of which is to be measured. Raman laser beams are directed through the cell from the end opposite the retroreflector, then pass back through the cell after striking the retroreflector. The Raman laser beams together with the cold atoms measure the relative acceleration, through the readout of the AIA, between the cold atoms and the retroreflector.

•Mar 1, 2009•3 citations

Inertial Sensors using Atom Interferometry.

Grant W. Biedermann

•Apr 1, 2015•0 citations

High Bandwidth Atom Interferometer for Measuring Dynamic Accelerations and Rotations.

Grant W. Biedermann, Akash Rakholia, Hayden McGuinness

•Apr 1, 2012•0 citations
Dual-atom-interferometer configurations are widely used in gyroscopes and gradiometers to suppress common-mode noise and extract inertial signals with high precision. However, phase coupling between the two interferometers arising from shared Raman laser fields poses a significant challenge to simultaneous fringe locking. Here, we demonstrate a dual-atom-interferometric gyroscope–accelerometer that simultaneously locks both interference fringes at their respective mid-fringe operating points using independent direct digital synthesizer (DDS) channels to control the Raman phase shifts of the two interferometers. The proposed dual-fringe-locking scheme independently stabilizes both interferometers while preserving the common-mode noise rejection inherent to the dual-interferometer configuration. Compared with conventional full-fringe scanning, the scheme enables simultaneous rotation-rate and acceleration measurements with a higher data rate and improved sensitivity in both channels. These results demonstrate the potential of dual-fringe locking for high-precision quantum inertial sensing.
Accelerometer systems that would combine the best features of both conventional (e.g., mechanical) accelerometers and atom interferometer accelerometers (AIAs) have been proposed. These systems are intended mainly for use in scientific research aboard spacecraft but may also be useful on Earth in special military, geological, and civil-engineering applications. Conventional accelerometers can be sensitive, can have high dynamic range, and can have high frequency response, but they lack accuracy and long-term stability. AIAs have low frequency response, but they offer high sensitivity, and high accuracy for measuring small accelerations. In a system according to the proposal, a conventional accelerometer would be used to perform short-term measurements of higher-frequency components of acceleration, while an AIA would be used to provide consistent calibration of, and correction of errors in, the measurements of the conventional accelerometer in the lower-frequency range over the long term. A brief description of an AIA is prerequisite to a meaningful description of a system according to the proposal. An AIA includes a retroreflector next to one end of a cell that contains a cold cloud of atoms in an ultrahigh vacuum. The atoms in the cloud are in free fall. The retroreflector is mounted on the object, the acceleration of which is to be measured. Raman laser beams are directed through the cell from the end opposite the retroreflector, then pass back through the cell after striking the retroreflector. The Raman laser beams together with the cold atoms measure the relative acceleration, through the readout of the AIA, between the cold atoms and the retroreflector.