Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Symposium on Frequency Standards and Metrology

EXPERIMENTS WITH A NEW 201 Hg + ION CLOCK

Eric A. Burt, S. Taghavi-Larigani, S.N. Lea, John D. Prestage, Robert L. Tjoelker

Published May 1, 2009• 1 citation
Publisher
DOI
10.1142/9789812838223_0043

Related papers

Spectroscopy of a single 199 Hg + ion

Mark G. Raizen, F. Elsner, Jonas Bergquist +2 more

•May 21, 1990•0 citations

Trapped Hg + ion frequency standard

John D. Prestage

•Jan 1, 1995•0 citations

Hg+ Single Ion Spectroscopy

Jonas Bergquist, F. Diedrich, Wayne M. Itano +1 more

Laser Spectroscopy•Jan 1, 1989•9 citations

Hg+ Single Ion Spectroscopy

Jonas Bergquist, F. Diedricht, Wayne M. Itano +1 more

Springer eBooks•Jan 1, 1989•3 citations

The Hg/Al single-atom, optical clocks: on the path to inaccuracies below 10 -17

Jonas Bergquist

Bulletin of the American Physical Society•Mar 14, 2006•0 citations

Cycle Time Reduction in Trapped Mercury Ion Atomic Frequency Standards

Eric A. Burt, Robert L. Tjoelker, S. Taghavi-Larigani

The use of the mercury ion isotope (201)Hg(+) was examined for an atomic clock. Taking advantage of the faster optical pumping time in (201)Hg(+) reduces both the state preparation and the state readout times, thereby decreasing the overall cycle time of the clock and reducing the impact of medium-term LO noise on the performance of the frequency standard. The spectral overlap between the plasma discharge lamp used for (201)Hg(+) state preparation and readout is much larger than that of the lamp used for the more conventional (199)Hg(+). There has been little study of (201)Hg(+) for clock applications (in fact, all trapped ion clock work in mercury has been with (199)Hg(+); however, recently the optical pumping time in (201)Hg(+) has been measured and found to be 0.45 second, or about three times faster than in (199)Hg(+) due largely to the better spectral overlap. This can be used to reduce the overall clock cycle time by over 2 seconds, or up to a factor of 2 improvement. The use of the (201)Hg(+) for an atomic clock is totally new. Most attempts to reduce the impact of LO noise have focused on reducing the interrogation time. In the trapped ion frequency standards built so far at JPL, the optical pumping time is already at its minimum so that no enhancement can be had by shortening it. However, by using (201)Hg(+), this is no longer the case. Furthermore, integrity monitoring, the mechanism that determines whether the clock is functioning normally, cannot happen faster than the clock cycle time. Therefore, a shorter cycle time will enable quicker detection of failure modes and recovery from them.

•Feb 1, 2011•0 citations
The use of the mercury ion isotope (201)Hg(+) was examined for an atomic clock. Taking advantage of the faster optical pumping time in (201)Hg(+) reduces both the state preparation and the state readout times, thereby decreasing the overall cycle time of the clock and reducing the impact of medium-term LO noise on the performance of the frequency standard. The spectral overlap between the plasma discharge lamp used for (201)Hg(+) state preparation and readout is much larger than that of the lamp used for the more conventional (199)Hg(+). There has been little study of (201)Hg(+) for clock applications (in fact, all trapped ion clock work in mercury has been with (199)Hg(+); however, recently the optical pumping time in (201)Hg(+) has been measured and found to be 0.45 second, or about three times faster than in (199)Hg(+) due largely to the better spectral overlap. This can be used to reduce the overall clock cycle time by over 2 seconds, or up to a factor of 2 improvement. The use of the (201)Hg(+) for an atomic clock is totally new. Most attempts to reduce the impact of LO noise have focused on reducing the interrogation time. In the trapped ion frequency standards built so far at JPL, the optical pumping time is already at its minimum so that no enhancement can be had by shortening it. However, by using (201)Hg(+), this is no longer the case. Furthermore, integrity monitoring, the mechanism that determines whether the clock is functioning normally, cannot happen faster than the clock cycle time. Therefore, a shorter cycle time will enable quicker detection of failure modes and recovery from them.