Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

CRC Press eBooks

New Ion Trapping Techniques

Published May 25, 2010• 0 citations
Publisher
DOI
10.1201/9781420083729-p2

Related papers

Digital ion trap mass spectrometry for cold ion-molecule chemistry

Laura L. Pollum

A promising new approach for studying cold ion-molecule chemical reactions is the combination of laser- or sympathetically-cooled trapped ions and slow-moving molecules from a cold molecule source, such as a quadrupole velocity selector or a Stark decelerator. Previous reaction studies using trapped atomic ions and slow molecules from a quadrupole velocity selector were able to reach average collision energies as low as 1 K. However, the guided molecules had an approximately room temperature rotational energy distribution, so the reactions studied were not truly cold. Thus, a new molecular source for producing translationally and rotationally cold molecules utilizing buffer gas cooling and quadrupole velocity selection was constructed by K. Twyman and characterized for use in cold reaction studies. This new source of cold molecules is referred to as the buffer gas guide. A new ion trap has been designed and built for use with the existing buffer gas guide. The new ion trap apparatus is compact and mechanically compatible with this new guide. It uses a linear Paul ion trap with cylindrical electrodes to trap ions. Two optical axes (one axial and one radial) enable efficient cooling of small ion crystals. A field-free time-of-flight tube and ion detection assembly are also incorporated into the apparatus. A new technique for determining the mass and quantity of trapped ions has also been developed, termed digital ion trap mass spectrometry. The new technique uses a digital RF waveform to trap ions before ejecting the ions radially from the trap using an ejection pulse applied to the trap electrodes. The ions are then detected after free flight along a time-of-flight tube. This technique was characterized by ejecting crystals of various sizes and compositions: Ca+ only, Ca+/CaF +, Ca+/CaOH +/CaOD+, and Ca+/NH +3 /NH +4 /H3O+. A linear relationship between the number of ions ejected (determined by comparing experimental and simulated crystal images) and the integral of the time-of-flight peak was observed for Ca+ and Ca+/CaF +. All mass peaks were resolved. Simulations of the trapped ions and their trajectories through the time-of-flight tube were also performed, and excellent agreement between the simulated and experimental mass resolution was observed. Progress towards combining the buffer gas guide with the previously independent ion trap is also presented. It is anticipated that the combined buffer gas guide ion trap apparatus will enable the study of ion-molecule reactions at low temperatures with translationally and rotationally cold molecules. It is anticipated that the new digital ion trap mass spectrometry technique will simplify the study of reactions when multiple product ions whose masses are separated by only 1 AMU are formed. A new ion trap has been designed and built for use with the existing buffer gas guide. The new ion trap apparatus is compact and mechanically compatible with this new guide. It uses a linear Paul ion trap with cylindrical electrodes to trap ions. Two optical axes (one axial and one radial) enable efficient cooling of small ion crystals. A field-free time-of-flight tube and ion detection assembly are also incorporated into the apparatus. A new technique for determining the mass and quantity of trapped ions has also been developed, termed digital ion trap mass spectrometry. The new technique uses a digital RF waveform to trap ions before ejecting the ions radially from the trap using an ejection pulse applied to the trap electrodes. The ions are then detected after free flight along a time-of-flight tube. This technique was characterized by ejecting crystals of various sizes and compositions: Ca+ only, Ca+/CaF+, Ca+/CaOH+/CaOD+, and Ca+/NH+3/NH+4/H3O+. A linear relationship between the number of ions ejected (determined by comparing experimental and simulated crystal images) and the integral of the time-of-flight peak was observed for Ca+ and Ca+/CaF+. All mass peaks were resolved. Simulations of the trapped ions and their trajectories through the time-of-flight tube were also performed, and excellent agreement between the simulated and experimental mass resolution was observed. Progress towards combining the buffer gas guide with the previously independent ion trap is also presented. It is anticipated that the combined buffer gas guide ion trap apparatus will enable the study of ion-molecule reactions at low temperatures with translationally and rotationally cold molecules. It is anticipated that the new digital ion trap mass spectrometry technique will simplify the study of reactions when multiple product ions whose masses are separated by only 1 AMU are formed.

•Jan 1, 2015•0 citations

Novel miniature ion traps

C. A. Schrama, E. Peik, W. W. Smith +1 more

Optics Communications•Aug 1, 1993•151 citations

A New Approach to Measurement of Heating Rate of Trapped Ions

You-Yang Xu, Zhou Fei, Yi Xie

We propose a new scheme to estimate the heating rate of trapped ions in thermal states. By applying a controlled-U gate between the internal and the motional states of one of the trapped ions, we could obtain the mean phonon number from the population of the internal state of the ion. The imperfection due to fluctuations of the relevant parameters in real experiments is considered and we analyze the experimental feasibility of our scheme with sophisticated ion trap techniques.

Communications in Theoretical Physics•Sep 1, 2010•0 citations

Principles of Ion Traps

Günther Werth

Lecture notes in physics•Jan 1, 2008•5 citations

Optimal Ion Trapping Experiment

Kevin J. Coakley

Physical Review E•May 10, 2007•0 citations

New scalable microfabrication method for surface ion traps and experimental results with trapped ions

Seokjun Hong, M. Lee, H. Cheon +4 more

This paper presents a new microfabrication method for surface ion traps and experimental results with trapped ions. Fabricating ion trap chips is a very formidable task because the top electrodes are vertically spaced more than 10 µm from the bottom electrodes with an indented dielectric layer in the middle. Previous ion traps were fabricated using TEOS timed etch or tungsten sacrificial etch techniques. This paper presents a new microfabrication method, using copper as a sacrificial material for an aluminum-oxide-aluminum ion trap structure. Using the developed method the overhang dimensions of the top aluminum electrodes can be accurately controlled. Fabricated ion trap chips are installed in a 1 × 10−11Torr vacuum environment for ion trapping experiments. Successful results in trapping strings of171Yb+and174Yb+ions as well as manipulating171Yb+ions for qubit operation are demonstrated.

IEEE International Conference on Micro Electro Mechanical Systems (MEMS)•Jan 1, 2015•1 citation
A promising new approach for studying cold ion-molecule chemical reactions is the combination of laser- or sympathetically-cooled trapped ions and slow-moving molecules from a cold molecule source, such as a quadrupole velocity selector or a Stark decelerator. Previous reaction studies using trapped atomic ions and slow molecules from a quadrupole velocity selector were able to reach average collision energies as low as 1 K. However, the guided molecules had an approximately room temperature rotational energy distribution, so the reactions studied were not truly cold. Thus, a new molecular source for producing translationally and rotationally cold molecules utilizing buffer gas cooling and quadrupole velocity selection was constructed by K. Twyman and characterized for use in cold reaction studies. This new source of cold molecules is referred to as the buffer gas guide. A new ion trap has been designed and built for use with the existing buffer gas guide. The new ion trap apparatus is compact and mechanically compatible with this new guide. It uses a linear Paul ion trap with cylindrical electrodes to trap ions. Two optical axes (one axial and one radial) enable efficient cooling of small ion crystals. A field-free time-of-flight tube and ion detection assembly are also incorporated into the apparatus. A new technique for determining the mass and quantity of trapped ions has also been developed, termed digital ion trap mass spectrometry. The new technique uses a digital RF waveform to trap ions before ejecting the ions radially from the trap using an ejection pulse applied to the trap electrodes. The ions are then detected after free flight along a time-of-flight tube. This technique was characterized by ejecting crystals of various sizes and compositions: Ca+ only, Ca+/CaF +, Ca+/CaOH +/CaOD+, and Ca+/NH +3 /NH +4 /H3O+. A linear relationship between the number of ions ejected (determined by comparing experimental and simulated crystal images) and the integral of the time-of-flight peak was observed for Ca+ and Ca+/CaF +. All mass peaks were resolved. Simulations of the trapped ions and their trajectories through the time-of-flight tube were also performed, and excellent agreement between the simulated and experimental mass resolution was observed. Progress towards combining the buffer gas guide with the previously independent ion trap is also presented. It is anticipated that the combined buffer gas guide ion trap apparatus will enable the study of ion-molecule reactions at low temperatures with translationally and rotationally cold molecules. It is anticipated that the new digital ion trap mass spectrometry technique will simplify the study of reactions when multiple product ions whose masses are separated by only 1 AMU are formed. A new ion trap has been designed and built for use with the existing buffer gas guide. The new ion trap apparatus is compact and mechanically compatible with this new guide. It uses a linear Paul ion trap with cylindrical electrodes to trap ions. Two optical axes (one axial and one radial) enable efficient cooling of small ion crystals. A field-free time-of-flight tube and ion detection assembly are also incorporated into the apparatus. A new technique for determining the mass and quantity of trapped ions has also been developed, termed digital ion trap mass spectrometry. The new technique uses a digital RF waveform to trap ions before ejecting the ions radially from the trap using an ejection pulse applied to the trap electrodes. The ions are then detected after free flight along a time-of-flight tube. This technique was characterized by ejecting crystals of various sizes and compositions: Ca+ only, Ca+/CaF+, Ca+/CaOH+/CaOD+, and Ca+/NH+3/NH+4/H3O+. A linear relationship between the number of ions ejected (determined by comparing experimental and simulated crystal images) and the integral of the time-of-flight peak was observed for Ca+ and Ca+/CaF+. All mass peaks were resolved. Simulations of the trapped ions and their trajectories through the time-of-flight tube were also performed, and excellent agreement between the simulated and experimental mass resolution was observed. Progress towards combining the buffer gas guide with the previously independent ion trap is also presented. It is anticipated that the combined buffer gas guide ion trap apparatus will enable the study of ion-molecule reactions at low temperatures with translationally and rotationally cold molecules. It is anticipated that the new digital ion trap mass spectrometry technique will simplify the study of reactions when multiple product ions whose masses are separated by only 1 AMU are formed.
This paper presents a new microfabrication method for surface ion traps and experimental results with trapped ions. Fabricating ion trap chips is a very formidable task because the top electrodes are vertically spaced more than 10 µm from the bottom electrodes with an indented dielectric layer in the middle. Previous ion traps were fabricated using TEOS timed etch or tungsten sacrificial etch techniques. This paper presents a new microfabrication method, using copper as a sacrificial material for an aluminum-oxide-aluminum ion trap structure. Using the developed method the overhang dimensions of the top aluminum electrodes can be accurately controlled. Fabricated ion trap chips are installed in a 1 × 10−11Torr vacuum environment for ion trapping experiments. Successful results in trapping strings of171Yb+and174Yb+ions as well as manipulating171Yb+ions for qubit operation are demonstrated.