Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Journal of Physics Conference Series

Atomic clock using coherent population trapping in a cesium cell: frequency stability and limitations

Sinda Mejri, François Tricot, Jean-Marie Danet, Peter Yun, Emeric de Clercq, Stéphane Guérandel

Published Jun 1, 2016• 4 citations
Publisher

Abstract

Toward the next generation of compact devices, atomic clocks based on coherent population trapping (CPT) offer a very interesting alternative. We present a review of our studies on the short and mid term stability of a compact high performance atomic clock based on CPT in view of portable applications.
DOI
10.1088/1742-6596/723/1/012014

Related papers

Compact atomic clock prototype based on coherent population trapping

Jean-Marie Danet, Olga Kozlova, Peter Yun +2 more

Toward the next generations of compact atomic clocks, clocks based on coherent population trapping (CPT) offer a very interesting alternative. Thanks to CPT, a quantum interfering process, this technology has made a decisive step in the miniaturization direction. Fractional frequency stability of 1.5x10-10 at 1 s has been demonstrated in commercial devices of a few cm3. The laboratory prototype presented here intends to explore what could be the ultimate stability of a CPT based device. To do so, an original double-Λ optical scheme and a pulsed interrogation have been implemented in order to get a good compromise between contrast and linewidth. A study of two main sources of noise, the relative intensity and the local oscillator (LO) noise, has been performed. By designing simple solutions, it led to a new fractional frequency limitation lower than 4x10-13 at 1 s integration. Such a performance proves that such a technology could rival with classical ones as double resonance clocks.

EPJ Web of Conferences•Jan 1, 2014•32 citations

Frequency Shifts in a Coherent Population Trapping Cs Vapor Cell Atomic Clock

Juliette Breurec, Moustafa Abdel Hafiz, Claudio Eligio Calosso +2 more

We report on measurements of frequency shifts in a microwave cesium vapor cell atomic clock based on coherent population trapping (CPT). The dependence of the clock frequency on numerous experimental parameters, such as the laser power, the laser frequency, the microwave power, the cell temperature, the static magnetic field, but also the temperature of some key components, or the translation and rotation of critical wave plates and optical elements, is investigated. The stability budget of the clock frequency at one day is reported and discussed. This study constitutes a solid database for the future demonstration of a CPT-based cell clock with enhanced mid- and long-term stability performances.

IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control•May 29, 2025•4 citations

Low-Drift Coherent Population Trapping Clock Based on Laser-Cooled Atoms and High-Coherence Excitation Fields

Xiaochi Liu, Eugene N. Ivanov, Valeriy I. Yudin +2 more

Atomic clocks based on coherent population trapping (CPT) are of great interest for portable applications, due to their high performance, low power requirements, and potential for miniaturization. Slow frequency drift, however, limits their holdover ability on long time scales. This study reports a CPT clock that minimizes long-term drift, with a fractional frequency stability of $3\ifmmode\times\else\texttimes\fi{}{10}^{-13}$ over the span of an hour---ten times as good as previous CPT clocks. After successful shrinking of the laser-cooling apparatus, this clock could see commercial use, as the atoms fall just a few millimeters during a typical probe period.

Physical Review Applied•Nov 2, 2017•54 citations

A compact coherent population trapping clock with a short-term fractional frequency stability of 4.2 x 10-13 τ-1/2

Peter Yun, Claudio Eligio Calosso, François Tricot +3 more

Based on the constructive polarization modulation coherent population trapping, we demonstrated a cw mode CPT clock with a short-term fractional frequency stability at the level of 4.2 x 10-13 ?-1/2 up to the averaging time of 100 seconds. This high performance and compact CPT atomic clock would lead more applications which concern on both the frequency stability and the compactness.

International Conference on Space Optics (ICSO)•Sep 25, 2017•0 citations

Double-Modulation Coherent Population Trapping Clock

Peter Yun, François Tricot, Claudio Eligio Calosso +5 more

Atomic clocks based on coherent population trapping and constructive polarization modulation are promising for high performance and compact devices. We have demonstrated a cw mode CPT clock with a short-term fractional frequency stability at the level of 3. \pmb2×10-13/√{τ} for a few 100 s integration time. This Double-Modulation CPT technology can be reduced to a miniature and robust setup due to its linear architecture. This clock could find future applications in industry, telecommunications, instrumentation, or global navigation satellite systems.

Conference on Precision Electromagnetic Measurements•Jul 1, 2018•0 citations

High performance compact atomic clock based on coherent population trapping

Stéphane Guérandel, Jean-Marie Danet, Peter Yun +1 more

This paper reports on our best performance achieved with a laboratory compact CPT caesium clock. The device is working in a pulsed regime with orthogonal linear polarizations arranged in the so-called double-lambda configuration using two separate phase-locked lasers tuned to the D1 line. The short term frequency stability has been measured at the level of 3.2×10−13τ−1/2. The mid-term stability is limited at a few 10−14after hundreds of seconds. The main noise sources impacting both short and mid terms are presented and discussed.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•May 1, 2014•4 citations
Toward the next generations of compact atomic clocks, clocks based on coherent population trapping (CPT) offer a very interesting alternative. Thanks to CPT, a quantum interfering process, this technology has made a decisive step in the miniaturization direction. Fractional frequency stability of 1.5x10-10 at 1 s has been demonstrated in commercial devices of a few cm3. The laboratory prototype presented here intends to explore what could be the ultimate stability of a CPT based device. To do so, an original double-Λ optical scheme and a pulsed interrogation have been implemented in order to get a good compromise between contrast and linewidth. A study of two main sources of noise, the relative intensity and the local oscillator (LO) noise, has been performed. By designing simple solutions, it led to a new fractional frequency limitation lower than 4x10-13 at 1 s integration. Such a performance proves that such a technology could rival with classical ones as double resonance clocks.
We report on measurements of frequency shifts in a microwave cesium vapor cell atomic clock based on coherent population trapping (CPT). The dependence of the clock frequency on numerous experimental parameters, such as the laser power, the laser frequency, the microwave power, the cell temperature, the static magnetic field, but also the temperature of some key components, or the translation and rotation of critical wave plates and optical elements, is investigated. The stability budget of the clock frequency at one day is reported and discussed. This study constitutes a solid database for the future demonstration of a CPT-based cell clock with enhanced mid- and long-term stability performances.
Atomic clocks based on coherent population trapping (CPT) are of great interest for portable applications, due to their high performance, low power requirements, and potential for miniaturization. Slow frequency drift, however, limits their holdover ability on long time scales. This study reports a CPT clock that minimizes long-term drift, with a fractional frequency stability of $3\ifmmode\times\else\texttimes\fi{}{10}^{-13}$ over the span of an hour---ten times as good as previous CPT clocks. After successful shrinking of the laser-cooling apparatus, this clock could see commercial use, as the atoms fall just a few millimeters during a typical probe period.
Atomic clocks based on coherent population trapping and constructive polarization modulation are promising for high performance and compact devices. We have demonstrated a cw mode CPT clock with a short-term fractional frequency stability at the level of 3. \pmb2×10-13/√{τ} for a few 100 s integration time. This Double-Modulation CPT technology can be reduced to a miniature and robust setup due to its linear architecture. This clock could find future applications in industry, telecommunications, instrumentation, or global navigation satellite systems.
This paper reports on our best performance achieved with a laboratory compact CPT caesium clock. The device is working in a pulsed regime with orthogonal linear polarizations arranged in the so-called double-lambda configuration using two separate phase-locked lasers tuned to the D1 line. The short term frequency stability has been measured at the level of 3.2×10−13τ−1/2. The mid-term stability is limited at a few 10−14after hundreds of seconds. The main noise sources impacting both short and mid terms are presented and discussed.