Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

中国化学快报:英文版

THE THEORY OF RESONANT AND NONRESONANT PUMP-PROBE POLARIZATION SPECTROSCOPY FOR GROUND-STATE COHERENCE 共振和非共振条件下电子基态相干运动的超快泵浦-探测偏振光谱的理论

赵仪 何国钟, He, Gz

Published Jan 1, 1996• 0 citations
OpenAlex

Related papers

A QUANTUM THEORY OF THE COHERENCE AND POLARIZATION OF LIGHT

Keh Pann

•Jan 1, 1969•0 citations

ON THE POLARIZATION THEORY OF RESONANCE EMISSION AND THE FLUORESCENCE OF ATOMIC AND DIATOMIC MOLECULES

P. P. Feofilov

•Oct 21, 1955•0 citations

PUMP-PROBE SPECTROSCOPY WITH ENTANGLED PHOTONS

Otgonbaatar Myagmar, Duger Ulam-Orgikh, Purevdorj Munkhbaatar

Международная научно-практическая конференция «Вызовы современности и стратегии развития общества в условиях новой реальности»•Jan 1, 2016•0 citations

Double resonance optical pumping-polarization spectroscopy of an excited state transition

Baodong Yang, Yi Liu, Junmin Wang

Optics Communications•May 26, 2020•7 citations

Coherent Pump-Probe Response of Quantum Wells: Polarization Dependence

Hoang Ngoc Cam

Journal of Russian Laser Research•Nov 1, 2013•0 citations

HIGH SENSITIVITY HETERODYNE-POLARIZATION SPECTROSCOPY

Michael G. Raab, A. C. Weber

Applying heterodyne detection $schemes^{1}$ to laser polarization $spectroscopy^{2}$ increases the sensitivity (S/N ratio) $considerably^{3}$. An acousto-optical modulator (AOM) shifts the pump frequency relative to the probe frequency by the amount of the driving frequency of the AOM thereby avoiding coherent noise due to interference of pump and probe/signal beams. At the same time the pump bean can be amplitude modulated at high frequencies (up to the MHz region) by means of the AOM thereby shifting the detection frequency towards more favorable regions of the laser noise spectrum. Interference of an optimized fraction of the probe bean with the spectroscopic signal generated through the non-linear mixing of the pump and probe beams by the medium finally amplifies the signal at a sensitivity close to the shot noise limit. Examples are given showing spectra of $^{3}\Pi_{u}\leftarrow ^{1}\Sigma_{g}^{+}$ transitions of $Na_{2} (\approx 10^{4}$ times less intense compared to the ``allowed"" $A^{1}\Sigma_{u}^{+}\leftarrow X^{1}\Sigma_{g}^{+}$ $transition^{4}$) and weak two photon absorption in a Na-heat pipe. Detection of components of the Na-D lines was accomplished in the vapor over the metal at room temperature and with $10^{3}-10^{4}$ atoms in the interaction volume. $^{1}$J. J. Snyder, R. K. Raj, D. Bloch, and M. Ducloy, Opt. Lett. 5. 163 (1980). $^{2}$C. Wieman and T. W. H\""{a}nsch, Phys. Rev. Lett. 36,(1170). $^{3}$M. D. Levenson and G. L. Eesley, Appl. Phys. 19, 1 (1979). $^{4}$J. B. Atkinson, J. Becker, and W. Demtr\""{o}der, Chem. Phys. Lett. 87, 92, 128 (1982).

•Jan 1, 1983•0 citations
Applying heterodyne detection schemes1schemes^{1}schemes1 to laser polarization spectroscopy2spectroscopy^{2}spectroscopy2 increases the sensitivity (S/N ratio) considerably3considerably^{3}considerably3. An acousto-optical modulator (AOM) shifts the pump frequency relative to the probe frequency by the amount of the driving frequency of the AOM thereby avoiding coherent noise due to interference of pump and probe/signal beams. At the same time the pump bean can be amplitude modulated at high frequencies (up to the MHz region) by means of the AOM thereby shifting the detection frequency towards more favorable regions of the laser noise spectrum. Interference of an optimized fraction of the probe bean with the spectroscopic signal generated through the non-linear mixing of the pump and probe beams by the medium finally amplifies the signal at a sensitivity close to the shot noise limit. Examples are given showing spectra of 3Πu←1Σg+^{3}\Pi_{u}\leftarrow ^{1}\Sigma_{g}^{+}3Πu​←1Σg+​ transitions of Na2(≈104Na_{2} (\approx 10^{4}Na2​(≈104 times less intense compared to the ``allowed"" A1Σu+←X1Σg+A^{1}\Sigma_{u}^{+}\leftarrow X^{1}\Sigma_{g}^{+}A1Σu+​←X1Σg+​ transition4transition^{4}transition4) and weak two photon absorption in a Na-heat pipe. Detection of components of the Na-D lines was accomplished in the vapor over the metal at room temperature and with 103−10410^{3}-10^{4}103−104 atoms in the interaction volume. 1^{1}1J. J. Snyder, R. K. Raj, D. Bloch, and M. Ducloy, Opt. Lett. 5. 163 (1980). 2^{2}2C. Wieman and T. W. H\""{a}nsch, Phys. Rev. Lett. 36,(1170). 3^{3}3M. D. Levenson and G. L. Eesley, Appl. Phys. 19, 1 (1979). 4^{4}4J. B. Atkinson, J. Becker, and W. Demtr\""{o}der, Chem. Phys. Lett. 87, 92, 128 (1982).