Towards mobile quantum sensors for gravity surveys

Alexander Niggebaum

Published Jul 1, 2016• 4 citations
OpenAlex

Abstract

Design and first characterisations of the mobile sensor head in the Gravity Gradient Technologies and Opportunities Programme (GGtop) are presented. The aim of the project is the development of a mobile gravity gradiometer and faces the challenge of condensing a normally lab filling experiment in a portable and robust package. A fibre network replaced free space optics light distribution and fibre based components free space equivalents. Although stable against misalignment, the systems performance is limited by polarization changes of the guided light which arise from birefringence fluctuations along the length of the network due to external temperature fluctuations and mechanical disturbances. These instabilities limit the achievable temperature of the trapped rubidium 87 cloud to approx. 18μK. In preparation for gravity measurements, Rabi oscillations and Ramsey fringes with a λ/2 time of 7.4μs were successfully demonstrated in a co-propagating Raman beam configuration. The atom cloud was launched as a first step towards gravity gradiometry. As the system was designed to be portable, the complete system fits into a 1.5m x 2m x 0.5m package, plus a 14u rack of support electronics.

Related papers

Development of a transportable cold atom gradiometer

Andrew Hinton

This work describes the technology developed for the transportable gravity gradiometer, ''GGtop", constructed at the University of Birmingham. The device aims to simultaneously interrogate two physically separated, free-falling cold atom clouds using the technique of Raman interferometry to perform differential gravity measurements. Such a technique will suppress common-mode noise sources, such as vibrations, that otherwise limit classical gravimeters and cold atom interferometers based on single-cloud measurements. The technique is expected to improve speed and sensitivity for field measurements greatly. \nUsing a combination of commercially available components and novel designs, intended to enhance portability and robustness, allowed for demonstration of atomic interference with the apparatus via Ramsey's method of separated oscillatory fields. The achieved fringe contrast of ~2%, defined as the difference in the number of atoms detected in IF = 2>, was limited by drifts stemming from some of the novel designs which prompted continued optimisation of the underpinning subsystems. To address performance issues parts of the experiment were redesigned with the goal of improving reliability at the expense of some portability. Using the retrofitted experiment, interference was once again achieved with fitted fringe spacing of 134.7±2.0 uS in good agreement with the 133.9 uS defined by the experimental control. A factor of 10 improvement in contrast was found with the central fringe demonstrating 18% of the atoms detected in the IF = 2> state when normalised to the total 3D MOT number. The 3.71 ± 0.01 kHz fitted linewidth of the central fringe gives a frequency uncertainty of 5.43 ± 0.01 x 10 - 7. This result leaves the experiment in a good position to begin making measurements of gravity.

•Dec 1, 2016•1 citation

Progress towards a space-borne quantum gravity gradiometer

Nan Yu, James M. Kohel, Jaime Ramirez-Serrano +3 more

Quantum interferometer gravity gradiometer for 3D mapping is a project for developing the technology of atom interferometer-based gravity sensor in space. The atom interferometer utilizes atomic particles as free fall test masses to measure inertial forces with unprecedented sensitivity and precision. It also allows measurements of the gravity gradient tensor components for 3D mapping of subsurface mass distribution. The overall approach is based on recent advances of laser cooling and manipulation of atoms in atomic and optical physics. Atom interferometers have been demonstrated in research laboratories for gravity and gravity gradient measurements. In this approach, atoms are first laser cooled to micro-kelvin temperatures. Then they are allowed to freefall in vacuum as true drag-free test masses. During the free fall, a sequence of laser pulses is used to split and recombine the atom waves to realize the interferometric measurements. We have demonstrated atom interferometer operation in the Phase I period, and we are implementing the second generation for a complete gradiometer demonstration unit in the laboratory. Along with this development, we are developing technologies at component levels that will be more suited for realization of a space instrument. We will present an update of these developments and discuss the future directions of the quantum gravity gradiometer project.

•Jun 22, 2004•6 citations

Construction of a Rubidium Fountain Atomic Interferometer for Gravity Gradiometry

JN Tinsley

Atomic interferometry is a highly precise metrological technique of interest to both fundamental and applied physics. One field in which atomic interferometry is of particular interest is gravimetry, where instruments based upon the controlled manipulation of atomic states have superseded the performance of classical devices. In such devices, a standing wave derived from laser beams with well-defined phase difference are used to impart momentum to atoms undergoing free fall, generating spatial superpositions along the axis of gravity, before returning the atoms to an overlapped final state for recombination. This thesis presents the design and experimental progress towards a gravity gradiometer based upon the interference of rubidium-87 atoms, cooled and launched in a fountain configuration. The fountain is leveraged from a decommissioned frequency standard, which has been re-purposed and redesigned for use as a combined absolute gravimeter and gravity gradiometer package. It is capable of loading 100 billion atoms in 100 ms and then cooling and launching these atoms in a moving molasses configuration, with a final temperature of 5 μK. Furthermore, the process can be quickly repeated, with a second cloud subsequently launched, reaching its apogee at the same time as the first cloud, allowing for the possibility of simultaneous measurement at different heights and, in the future, the inference of the gravity gradient. Control of the fountain is provided by a stable and miniaturised optical setup, allowing for use with a future transportable or field-based device. A Raman beam system to perform the interferometry sequence has been constructed and characterised, likewise designed in a minaturised and stable manner. The Raman beams simultaneously generated Ramsey interference fringes on two independent clouds of atoms -- one launched to a height of 0.7 m and the other to 1 m. Such fringes were clearly observable after 200 ms of evolution time. Mach-Zehnder interference fringes were also demonstrated for dropped and launched atoms, providing the capability for gravimetric measurements to be made once the system has been fully characterised. The principle causes of noise in the Mach-Zehnder cases were identified as arriving from a lack of atoms and the phase noise of the Raman beams. To overcome these challenges, a new Raman beam system has been preliminary designed and tested and a new iteration of the fountain, moving towards quantum degeneracy, has been planned.

•Jan 1, 2019•2 citations

A portable magneto-optical trap with prospects for atom interferometry in civil engineering

Andrew Hinton, Marisa Perea-Ortiz, Jonathan Winch +21 more

The high precision and scalable technology offered by atom interferometry has the opportunity to profoundly affect gravity surveys, enabling the detection of features of either smaller size or greater depth. While such systems are already starting to enter into the commercial market, significant reductions are required in order to reach the size, weight and power of conventional devices. In this article, the potential for atom interferometry based gravimetry is assessed, suggesting that the key opportunity resides within the development of gravity gradiometry sensors to enable drastic improvements in measurement time. To push forward in realizing more compact systems, techniques have been pursued to realize a highly portable magneto-optical trap system, which represents the core package of an atom interferometry system. This can create clouds of 10 7 atoms within a system package of 20 l and 10 kg, consuming 80 W of power. This article is part of the themed issue ‘Quantum technology for the 21st century’.

Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences•Jun 26, 2017•63 citations

Sensitive gravity-gradiometry with atom interferometry: progress towards an improved determination of the gravitational constant

Fiodor Sorrentino, Yu-Hung Lien, G. Rosi +3 more

We here present a high sensitivity gravity-gradiometer based on atom interferometry. In our apparatus, two clouds of laser-cooled rubidium atoms are launched in fountain configuration and interrogated by a Raman interferometry sequence to probe the gradient of gravity field. We recently implemented a high-flux atomic source and a newly designed Raman lasers system in the instrument set-up. We discuss the applications towards a precise determination of the Newtonian gravitational constant G. The long-term stability of the instrument and the signal-to-noise ratio demonstrated here open interesting perspectives for pushing the measurement precision below the 100 ppm level.

arXiv:1002.3549•New Journal of Physics•Sep 24, 2010•51 citations

Optimisation of a compact cold-atoms interferometer for gravimetry

Clemens Rammeloo

The work presented in this thesis focusses on the development of a transportable atom-interferometry experiment and a compact fibre laser system towards precision measurements of gravitational acceleration. Interference fringes are shown with clouds of cold 87Rb atoms using co-propagating laser beams to drive stimulated Raman transitions. This is demonstrated both inside and outside of laboratory environments for which an integrated and transportable experiment is constructed. Further improvements are presented that enable the generation of clouds containing 1.7 · 108 atoms at a rate of 2.5 Hz and having a temperature of (7 ± 1) µK. This is largely due to the development of a compact laser system based on all-fibre coupled components. It is demonstrated that the laser system designed here can achieve fast frequency sweeps over 1.8 GHz within 2 ms, making it widely applicable in compact atom-interferometry experiments with rubidium atoms. This is shown by creating a Mach–Zehnder type interferometer with counter-propagating Raman beams, thus enabling measurements of gravitational acceleration. Since the laser system uses only two lasers and one fibre amplifier, a significant reduction in size is achieved, as well as a decrease in the total power consumption of the overall experiment by a third to (162 ± 7) W.

•Jul 1, 2018•1 citation
Design and first characterisations of the mobile sensor head in the Gravity Gradient Technologies and Opportunities Programme (GGtop) are presented. The aim of the project is the development of a mobile gravity gradiometer and faces the challenge of condensing a normally lab filling experiment in a portable and robust package. A fibre network replaced free space optics light distribution and fibre based components free space equivalents. Although stable against misalignment, the systems performance is limited by polarization changes of the guided light which arise from birefringence fluctuations along the length of the network due to external temperature fluctuations and mechanical disturbances. These instabilities limit the achievable temperature of the trapped rubidium 87 cloud to approx. 18μK. In preparation for gravity measurements, Rabi oscillations and Ramsey fringes with a λ/2 time of 7.4μs were successfully demonstrated in a co-propagating Raman beam configuration. The atom cloud was launched as a first step towards gravity gradiometry. As the system was designed to be portable, the complete system fits into a 1.5m x 2m x 0.5m package, plus a 14u rack of support electronics.
This work describes the technology developed for the transportable gravity gradiometer, ''GGtop", constructed at the University of Birmingham. The device aims to simultaneously interrogate two physically separated, free-falling cold atom clouds using the technique of Raman interferometry to perform differential gravity measurements. Such a technique will suppress common-mode noise sources, such as vibrations, that otherwise limit classical gravimeters and cold atom interferometers based on single-cloud measurements. The technique is expected to improve speed and sensitivity for field measurements greatly. \nUsing a combination of commercially available components and novel designs, intended to enhance portability and robustness, allowed for demonstration of atomic interference with the apparatus via Ramsey's method of separated oscillatory fields. The achieved fringe contrast of ~2%, defined as the difference in the number of atoms detected in IF = 2>, was limited by drifts stemming from some of the novel designs which prompted continued optimisation of the underpinning subsystems. To address performance issues parts of the experiment were redesigned with the goal of improving reliability at the expense of some portability. Using the retrofitted experiment, interference was once again achieved with fitted fringe spacing of 134.7±2.0 uS in good agreement with the 133.9 uS defined by the experimental control. A factor of 10 improvement in contrast was found with the central fringe demonstrating 18% of the atoms detected in the IF = 2> state when normalised to the total 3D MOT number. The 3.71 ± 0.01 kHz fitted linewidth of the central fringe gives a frequency uncertainty of 5.43 ± 0.01 x 10 - 7. This result leaves the experiment in a good position to begin making measurements of gravity.
Quantum interferometer gravity gradiometer for 3D mapping is a project for developing the technology of atom interferometer-based gravity sensor in space. The atom interferometer utilizes atomic particles as free fall test masses to measure inertial forces with unprecedented sensitivity and precision. It also allows measurements of the gravity gradient tensor components for 3D mapping of subsurface mass distribution. The overall approach is based on recent advances of laser cooling and manipulation of atoms in atomic and optical physics. Atom interferometers have been demonstrated in research laboratories for gravity and gravity gradient measurements. In this approach, atoms are first laser cooled to micro-kelvin temperatures. Then they are allowed to freefall in vacuum as true drag-free test masses. During the free fall, a sequence of laser pulses is used to split and recombine the atom waves to realize the interferometric measurements. We have demonstrated atom interferometer operation in the Phase I period, and we are implementing the second generation for a complete gradiometer demonstration unit in the laboratory. Along with this development, we are developing technologies at component levels that will be more suited for realization of a space instrument. We will present an update of these developments and discuss the future directions of the quantum gravity gradiometer project.
Atomic interferometry is a highly precise metrological technique of interest to both fundamental and applied physics. One field in which atomic interferometry is of particular interest is gravimetry, where instruments based upon the controlled manipulation of atomic states have superseded the performance of classical devices. In such devices, a standing wave derived from laser beams with well-defined phase difference are used to impart momentum to atoms undergoing free fall, generating spatial superpositions along the axis of gravity, before returning the atoms to an overlapped final state for recombination. This thesis presents the design and experimental progress towards a gravity gradiometer based upon the interference of rubidium-87 atoms, cooled and launched in a fountain configuration. The fountain is leveraged from a decommissioned frequency standard, which has been re-purposed and redesigned for use as a combined absolute gravimeter and gravity gradiometer package. It is capable of loading 100 billion atoms in 100 ms and then cooling and launching these atoms in a moving molasses configuration, with a final temperature of 5 μK. Furthermore, the process can be quickly repeated, with a second cloud subsequently launched, reaching its apogee at the same time as the first cloud, allowing for the possibility of simultaneous measurement at different heights and, in the future, the inference of the gravity gradient. Control of the fountain is provided by a stable and miniaturised optical setup, allowing for use with a future transportable or field-based device. A Raman beam system to perform the interferometry sequence has been constructed and characterised, likewise designed in a minaturised and stable manner. The Raman beams simultaneously generated Ramsey interference fringes on two independent clouds of atoms -- one launched to a height of 0.7 m and the other to 1 m. Such fringes were clearly observable after 200 ms of evolution time. Mach-Zehnder interference fringes were also demonstrated for dropped and launched atoms, providing the capability for gravimetric measurements to be made once the system has been fully characterised. The principle causes of noise in the Mach-Zehnder cases were identified as arriving from a lack of atoms and the phase noise of the Raman beams. To overcome these challenges, a new Raman beam system has been preliminary designed and tested and a new iteration of the fountain, moving towards quantum degeneracy, has been planned.
The high precision and scalable technology offered by atom interferometry has the opportunity to profoundly affect gravity surveys, enabling the detection of features of either smaller size or greater depth. While such systems are already starting to enter into the commercial market, significant reductions are required in order to reach the size, weight and power of conventional devices. In this article, the potential for atom interferometry based gravimetry is assessed, suggesting that the key opportunity resides within the development of gravity gradiometry sensors to enable drastic improvements in measurement time. To push forward in realizing more compact systems, techniques have been pursued to realize a highly portable magneto-optical trap system, which represents the core package of an atom interferometry system. This can create clouds of 10 7 atoms within a system package of 20 l and 10 kg, consuming 80 W of power. This article is part of the themed issue ‘Quantum technology for the 21st century’.
We here present a high sensitivity gravity-gradiometer based on atom interferometry. In our apparatus, two clouds of laser-cooled rubidium atoms are launched in fountain configuration and interrogated by a Raman interferometry sequence to probe the gradient of gravity field. We recently implemented a high-flux atomic source and a newly designed Raman lasers system in the instrument set-up. We discuss the applications towards a precise determination of the Newtonian gravitational constant G. The long-term stability of the instrument and the signal-to-noise ratio demonstrated here open interesting perspectives for pushing the measurement precision below the 100 ppm level.
The work presented in this thesis focusses on the development of a transportable atom-interferometry experiment and a compact fibre laser system towards precision measurements of gravitational acceleration. Interference fringes are shown with clouds of cold 87Rb atoms using co-propagating laser beams to drive stimulated Raman transitions. This is demonstrated both inside and outside of laboratory environments for which an integrated and transportable experiment is constructed. Further improvements are presented that enable the generation of clouds containing 1.7 · 108 atoms at a rate of 2.5 Hz and having a temperature of (7 ± 1) µK. This is largely due to the development of a compact laser system based on all-fibre coupled components. It is demonstrated that the laser system designed here can achieve fast frequency sweeps over 1.8 GHz within 2 ms, making it widely applicable in compact atom-interferometry experiments with rubidium atoms. This is shown by creating a Mach–Zehnder type interferometer with counter-propagating Raman beams, thus enabling measurements of gravitational acceleration. Since the laser system uses only two lasers and one fibre amplifier, a significant reduction in size is achieved, as well as a decrease in the total power consumption of the overall experiment by a third to (162 ± 7) W.