Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Bulletin of the American Physical Society

Sub-Wavelength Microwave Electric Field Imaging using Rydberg Atoms

Haoquan Fan, Santosh Kumar, Renate Daschner, Harald K ubler, James P. Shaffer

Published Jun 5, 2014• 0 citations
OpenAlex

Related papers

Rydberg-atom-based electric field sensing: continuous-frequency measurements of high-intensity microwave electric fields

David Alexander Anderson, Georg A. Raithel, Éric Paradis +2 more

Bulletin of the American Physical Society•Jun 9, 2017•0 citations

Rydberg-atom-based electrometry

Huang Wei, Liang Zhen-Tao, Du Yan-Xiong +2 more

Atom in Rydberg state has large polarizability, large electric dipole and low ionization threshold field. It is very sensitive to electric field, therefore it can be used to measure the amplitude of electric field, especially the microwave electric field. The new developed scheme is based on quantum interference effects (electromagnetically induced transparency and Autler-Townes splitting) in Rydberg atoms. Instead of the direct amplitude measurement, this method tests the Rabi frequency value of the transmission spectrum which is determined by the microwave electric field strength and the corresponding atom nature. The minimum measured strengths of microwave electric fields are far below the standard values obtained by traditional antenna methods. Compared with the traditional methods, this new scheme has several advantages, such as self-calibration, non-perturbation to the measured field and independence of the probe length. Besides, this scheme can also be used to measure the polarization direction of microwave electric field and realize sub-wavelength imaging. Through adjusting the wavelength of coupling laser, a broadband 1-500 GHz microwave electric field measurement can be achieved. This new scheme is benefitial to conducting the continue electric field measurement and the miniaturization of the test equipment. In this paper, the researches about using Rydberg atom to measure electric field with high precision are reviewed. The basic theory and experimental techniques are introduced. Finally, we discuss a promising method of using Rydberg atom interferometer to detect the accumulated phase in the process of interaction between electric field and Rydberg atoms. This method converts amplitude measurement into phase test, which may improve the precision and sensitivity.

Acta Physica Sinica•Jan 1, 2015•17 citations

Advanced Techniques for Microwave Field Measurement Using Rydberg Atoms

Haitao Yu, Guilan Li, He Hao +1 more

Communications in computer and information science•Aug 19, 2025•1 citation

Probing RF electric fields with Rydberg atoms

Arne Schwettmann, Jonathon A. Sedlacek, Cale M. Gentry +1 more

Bulletin of the American Physical Society•Jun 17, 2011•0 citations

Microwave Electric Field Measurement Based on Electromagnetically-Induced Transparency and Absorption in Atomic Vapor Cell at Room Temperature

Xiaohong Liu, Jie Liang, Changjun Chen +2 more

The traceability of microwave electric field is measured based on the Rydberg atomic quantum interference effect. The rubidium atomic vapor cell at room temperature is used as the probe, and the Autler-Townes splitting of two-photon electromagnetically-induced transparency, three-photon electromagnetically-induced transparency and three-photon electromagnetically-induced absorption effect are analyzed theoretically. The measurement limit of atomic shot noise is also discussed. This method is not only suitable for the traceability and self-calibration measurement of the microwave electric field but also for the sub-wavelength imaging and vector measurement of the microwave electric field and will provide a reference for further miniaturization and integration of the atomic microwave probe.

华南师范大学学报(自然科学版)•Jun 25, 2020•0 citations

Rydberg atoms in microwave fields

Thomas F. Gallagher

Annual Meeting Optical Society of America•Jan 1, 1993•0 citations
Atom in Rydberg state has large polarizability, large electric dipole and low ionization threshold field. It is very sensitive to electric field, therefore it can be used to measure the amplitude of electric field, especially the microwave electric field. The new developed scheme is based on quantum interference effects (electromagnetically induced transparency and Autler-Townes splitting) in Rydberg atoms. Instead of the direct amplitude measurement, this method tests the Rabi frequency value of the transmission spectrum which is determined by the microwave electric field strength and the corresponding atom nature. The minimum measured strengths of microwave electric fields are far below the standard values obtained by traditional antenna methods. Compared with the traditional methods, this new scheme has several advantages, such as self-calibration, non-perturbation to the measured field and independence of the probe length. Besides, this scheme can also be used to measure the polarization direction of microwave electric field and realize sub-wavelength imaging. Through adjusting the wavelength of coupling laser, a broadband 1-500 GHz microwave electric field measurement can be achieved. This new scheme is benefitial to conducting the continue electric field measurement and the miniaturization of the test equipment. In this paper, the researches about using Rydberg atom to measure electric field with high precision are reviewed. The basic theory and experimental techniques are introduced. Finally, we discuss a promising method of using Rydberg atom interferometer to detect the accumulated phase in the process of interaction between electric field and Rydberg atoms. This method converts amplitude measurement into phase test, which may improve the precision and sensitivity.
The traceability of microwave electric field is measured based on the Rydberg atomic quantum interference effect. The rubidium atomic vapor cell at room temperature is used as the probe, and the Autler-Townes splitting of two-photon electromagnetically-induced transparency, three-photon electromagnetically-induced transparency and three-photon electromagnetically-induced absorption effect are analyzed theoretically. The measurement limit of atomic shot noise is also discussed. This method is not only suitable for the traceability and self-calibration measurement of the microwave electric field but also for the sub-wavelength imaging and vector measurement of the microwave electric field and will provide a reference for further miniaturization and integration of the atomic microwave probe.