Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

IEEE Transactions on Applied Superconductivity

Dependence of SQUID Intrinsic Flux Noise on Stewart–McCumber Parameter $\beta_{c}$ of Josephson Junction

Hai Wang, Yongliang Wang, Xiangyan Kong, Guofeng Zhang, Yi Zhang, Xiaoming Xie

Published May 12, 2016• 4 citations
Publisher

Abstract

It is known that three superconducting quantum interference device (SQUID) parameters, namely, the intrinsic flux noise δΦs, the flux-to-voltage transfer coefficient ∂V/∂Φ, and the dynamic resistance Rd, increase with increasing the Stewart- McCumber parameter βcof Josephson junction. It is very difficult to obtain the low values of δΦsfor a strongly damped SQUID due to its small ∂V/∂Φ. In this paper, we employ a two-stage scheme (TSS) to measure δΦsdirectly. Here, we use single chip readout electronics and a weakly damped SQUID with a βcof flux noise of the readout-SQUID system is about 4.8 μΦ0/√Hz 1.2, both acting as a readout-SQUID system (a preamplifier). The with a corner frequency of about 10 Hz. The front-end SQUID is coupled to the readout SQUID via the input coil with a mutual inductance of Mi. In our experiment, the flux gain for a readout SQUID, i.e., GΦ= Mi× (∂I/∂Φ)front-endis adjusted to be 20. Using the TSS, we measured δΦswith different βcchanging from 0.3 to 13.5 and found δΦsincreasing from 1.0 to 5.0 μΦ0/√Hz. We also discussed the relations between Ls, βc, and δΦsquantitatively. Finally, we proposed designing a suitable βcto match the preamplifier in a direct readout scheme to simplify a SQUID measurement system.

DOI
10.1109/tasc.2016.2565605

Related papers

Study on Noise Matching Between SQUID Sensor and Its Readout Electronics

Hai Wang, Hua Chen, Xiangyan Kong +3 more

Noise matching between superconducting quantum interference device (SQUID) sensor and readout electronics has always been an important problem. Conventionally, in order to avoid the hysteresis, SQUIDs should be operated in the range of βccis the Stewart-McCumber parameter. Recently, Liu et al. extended the SQUID operating area to βc > 1 due to a large noise parameter Γ*. When βc> 1, SQUID exhibits a large ∂V/∂Φ, which is beneficial in reducing the noise contribution of the readout electronics, δΦe. In this work, we compare the SQUID system noise δΦsmeasured with four different readout electronics. Here, the four readout electronics employed are as follows: 1) the flux modulation scheme (FMS); 2) the direct readout scheme (DRS), which uses six parallel connected bipolar transistor as its preamplifier (DRS-PCBT); 3) the DRS, which uses a single preamplifier AD797 (DRS-AD797); and 4) the two-stage scheme. The preamplifier voltage noise of DRS-PCBT and DRS-AD797 are about 0.4 nV/√Hz and 0.9 nV/√Hz, respectively. For a two-stage scheme, the equivalent flux noise reaches about 0.25 μΦ0/√Hz, the measured SQUID intrinsic noise, δΦi, will dominate δΦs. In other readout schemes, however, δΦsdepends on the value of βc. Finally, we found that FMS is suitable to match SQUIDs with βccc> 3.

IEEE Transactions on Applied Superconductivity•Nov 30, 2016•4 citations

Superconducting quantum interference devices with different damped junctions operated in directly coupled current- and voltage-bias modes

Jia Zeng, Yi Zhang, Yang Qiu +4 more

We investigate niobium thin film superconducting quantum interference devices (SQUIDs) with different Steward—McCumber parameters βc operated in both current- and voltage-bias modes. We experimentally prove that there is no difference between the two bias modes with respect to the SQUID intrinsic noise and the noise contribution from the preamplifier. Furthermore, the relationships of the SQUID dynamic parameters, (Rd)current bias ≈ (Rd)voltage bias and (∂V/∂Φ)current bias ≈ [(∂i/∂Φ)Rd]voltage bias, are always satisfied. For a strongly damped SQUID with βc ≈ 0.25, additional positive feedback (APF) and noise cancellation (NC) were employed to enhance ∂V/∂Φ, the former showing a degradation in the linear flux range but otherwise the same with NC. For a weakly damped SQUID with βc ≈ 3, it is directly connected to the preamplifier without APF or NC, and a low SQUID system noise of about 4 μΦ0/√Hz is measured, which is close to its intrinsic noise.

Chinese Physics B•Nov 1, 2014•2 citations

Broadband SQUID amplifiers for photonic applications

Vladimir Polushkin, D. Glowacka, R. Hart +1 more

The dynamics and noise of a dc SQUID (the Superconducting Quantum Interference Device), with the McCumber parameter /spl beta//sub c/=2/spl pi/R/sup 2/l/sub c/C//spl Phi//sub 0/ close to the unity (where I/sub c/, R, C is the critical current, the shunt resistance and the capacitance of the Josephson junctions comprising the SQUID, respectively, /spl Phi//sub 0/=2.07 10/sup -15/ Wb is the magnetic flux quantum) integrated with a planar spiral input coil, have been experimentally studied. The length of the spiral input coil was chosen so as to match its /spl lambda//4 microwave resonance frequency to the plasma resonance frequency of the SQUID. The input coil resonance is found to enhance the overall quality factor Q of the Josephson oscillations in the SQUID and, as a result, to increase the dynamic resistance R/sub d/ and the gradient of the flux-to-voltage characteristics, /spl delta/V//spl delta//spl Phi/, without hysteresis. A dc SQUID with a loop inductance L=30.5 pH, /spl beta//sub c/=0.72, and a 6 turn input coil demonstrated a non-distorted quasi-sinusoidal flux-to-voltage transfer function with an exceptionally large modulation depth of 140 /spl mu/V peak-to-peak. The spectral density of the magnetic flux noise was as low as 3.5/spl times/10/sup -7/ /spl Phi//sub 0//Hz/sup 1/2/ in the double stage configuration, measured at a temperature 4.2 K using direct read out electronics. In combination with an intermediary transformer, the current resolution of the SQUID is as low as 1.25 pA/Hz/sup 1/2/ with an input coil inductance of 100 nH.

IEEE Transactions on Applied Superconductivity•Jun 1, 1999•1 citation

Effect of an input coil microwave resonance on dynamics and noise properties of a dc superconducting quantum interference device operating close to the hysteretic mode

Vladimir Polushkin, D. Glowacka, R. Hart +1 more

The dynamics and noise of a dc superconducting quantum interference device (SQUID) with the McCumber parameter βc=2πR2IcC/Φ0 close to the unity (where Ic, R, C are the critical current, the shunt resistance, and the capacitance of the Josephson junctions comprising the SQUID, respectively, and Φ0=2.07×10−15 Wb is the magnetic flux quantum) integrated with a planar spiral input coil have been experimentally studied. The length of the spiral input coil was chosen to match its λ/4 microwave resonance frequency to the plasma resonance frequency of the SQUID. The input coil resonance enhances the overall quality factor Q of the Josephson oscillations in the SQUID and, as a result, increases the dynamic resistance Rd and the gradient of the flux-to-voltage characteristics ∂V/∂Φ without hysteresis. This relaxes the tolerance for the βc parameter, simplifies the technological process, and improves the yield of devices. A dc SQUID with loop inductance L=31.4 pH, βc=0.72, and a six turn input coil has demonstrated a nondistorted quasisinusoidal flux-to-voltage transfer function with an exceptionally large modulation depth of approximately 140 μV peak-to-peak. A spectral density of the intrinsic magnetic flux noise as low as 3.5×10−7 Φ0/Hz1/2 has been measured in the double stage configuration at a temperature of 4.2 K using direct read-out electronics. This corresponds to the intrinsic energy resolution of ε=12.5h. In combination with an intermediary transformer, the current resolution of the SQUID is as low as 1.25 pA/Hz1/2 with an input coil inductance of 58 nH. The coupled energy resolution is εc=45h in the white noise region.

Review of Scientific Instruments•Mar 1, 1999•9 citations

Study of the Flux-to-Voltage Characteristics of DC SQUID With a Small Screening Parameter and a Large Stewart-McCumber Parameter

Bao Wu, Hai Wang, Zhidan Zhang +2 more

It is known that SQUID has three important parameters, namely, Stewart-McCumber parameterβC, Screening parameterβLand thermal noise parameterΓ. They play a very important role in SQUID performance, especiallyβC. Recently, researchers extended the SQUID operating area toβc > 1 due to a large noise parameterΓin experiments. WhenβC> 1, SQUID exhibits a large flux-voltage transfer coefficient∂V/∂Φ, which is beneficial in reducing the noise contribution of the readout circuitδΦe. From the simulation results, we found that whenβC>1, SQUID produces a larger∂V/∂Φ thanβC∂V/∂Φ increases with the decrease ofβL. In order to further verify our findings, we selected two groups of SQUIDs for experiments (βCβC> 1), by changing the value of the shunt resistance on the Josephson junction to adjust the value of changingβC, and then we observe the value of∂V/∂Φ. Finally, we find that whenβL∂V/∂Φ of SQUID increases whileβCincreasing. A large∂V/∂Φ will help us to obtain an optimal SQUID measure system.

IEEE Transactions on Applied Superconductivity•Aug 12, 2021•3 citations

An insight into voltage-biased superconducting quantum interference devices

Chao Liu, Yi Zhang, Michael Mück +5 more

We experimentally studied two important parameters of helium-cooled superconducting quantum interference devices (SQUIDs) in the voltage bias mode: the dynamic resistance Rd and the flux-to-current transfer coefficient ∂i/∂Φ, with different junction shunt resistors RJ. We investigated a voltage-biased SQUID using the direct readout current-to-voltage converter scheme involving an operational amplifier. At higher RJ, the flux-to-voltage conversion coefficient ∂V/∂Φ becomes sufficiently large to effectively suppress the room-temperature amplifier's noise without any need for additional feedback circuits. The McCumber parameter limits the rise of ∂V/∂Φ. We discuss the performance of voltage-biased SQUIDs at different effective McCumber parameters.

Applied Physics Letters•Nov 26, 2012•20 citations
Dependence of SQUID Intrinsic Flux Noise on Stewart–McCumber Parameter βc\beta_{c}βc​ of Josephson Junction
It is known that three superconducting quantum interference device (SQUID) parameters, namely, the intrinsic flux noise δΦs, the flux-to-voltage transfer coefficient ∂V/∂Φ, and the dynamic resistance Rd, increase with increasing the Stewart- McCumber parameter βcof Josephson junction. It is very difficult to obtain the low values of δΦsfor a strongly damped SQUID due to its small ∂V/∂Φ. In this paper, we employ a two-stage scheme (TSS) to measure δΦsdirectly. Here, we use single chip readout electronics and a weakly damped SQUID with a βcof flux noise of the readout-SQUID system is about 4.8 μΦ0/√Hz 1.2, both acting as a readout-SQUID system (a preamplifier). The with a corner frequency of about 10 Hz. The front-end SQUID is coupled to the readout SQUID via the input coil with a mutual inductance of Mi. In our experiment, the flux gain for a readout SQUID, i.e., GΦ= Mi× (∂I/∂Φ)front-endis adjusted to be 20. Using the TSS, we measured δΦswith different βcchanging from 0.3 to 13.5 and found δΦsincreasing from 1.0 to 5.0 μΦ0/√Hz. We also discussed the relations between Ls, βc, and δΦsquantitatively. Finally, we proposed designing a suitable βcto match the preamplifier in a direct readout scheme to simplify a SQUID measurement system.
Noise matching between superconducting quantum interference device (SQUID) sensor and readout electronics has always been an important problem. Conventionally, in order to avoid the hysteresis, SQUIDs should be operated in the range of βccis the Stewart-McCumber parameter. Recently, Liu et al. extended the SQUID operating area to βc > 1 due to a large noise parameter Γ*. When βc> 1, SQUID exhibits a large ∂V/∂Φ, which is beneficial in reducing the noise contribution of the readout electronics, δΦe. In this work, we compare the SQUID system noise δΦsmeasured with four different readout electronics. Here, the four readout electronics employed are as follows: 1) the flux modulation scheme (FMS); 2) the direct readout scheme (DRS), which uses six parallel connected bipolar transistor as its preamplifier (DRS-PCBT); 3) the DRS, which uses a single preamplifier AD797 (DRS-AD797); and 4) the two-stage scheme. The preamplifier voltage noise of DRS-PCBT and DRS-AD797 are about 0.4 nV/√Hz and 0.9 nV/√Hz, respectively. For a two-stage scheme, the equivalent flux noise reaches about 0.25 μΦ0/√Hz, the measured SQUID intrinsic noise, δΦi, will dominate δΦs. In other readout schemes, however, δΦsdepends on the value of βc. Finally, we found that FMS is suitable to match SQUIDs with βccc> 3.
We investigate niobium thin film superconducting quantum interference devices (SQUIDs) with different Steward—McCumber parameters βc operated in both current- and voltage-bias modes. We experimentally prove that there is no difference between the two bias modes with respect to the SQUID intrinsic noise and the noise contribution from the preamplifier. Furthermore, the relationships of the SQUID dynamic parameters, (Rd)current bias ≈ (Rd)voltage bias and (∂V/∂Φ)current bias ≈ [(∂i/∂Φ)Rd]voltage bias, are always satisfied. For a strongly damped SQUID with βc ≈ 0.25, additional positive feedback (APF) and noise cancellation (NC) were employed to enhance ∂V/∂Φ, the former showing a degradation in the linear flux range but otherwise the same with NC. For a weakly damped SQUID with βc ≈ 3, it is directly connected to the preamplifier without APF or NC, and a low SQUID system noise of about 4 μΦ0/√Hz is measured, which is close to its intrinsic noise.
The dynamics and noise of a dc SQUID (the Superconducting Quantum Interference Device), with the McCumber parameter /spl beta//sub c/=2/spl pi/R/sup 2/l/sub c/C//spl Phi//sub 0/ close to the unity (where I/sub c/, R, C is the critical current, the shunt resistance and the capacitance of the Josephson junctions comprising the SQUID, respectively, /spl Phi//sub 0/=2.07 10/sup -15/ Wb is the magnetic flux quantum) integrated with a planar spiral input coil, have been experimentally studied. The length of the spiral input coil was chosen so as to match its /spl lambda//4 microwave resonance frequency to the plasma resonance frequency of the SQUID. The input coil resonance is found to enhance the overall quality factor Q of the Josephson oscillations in the SQUID and, as a result, to increase the dynamic resistance R/sub d/ and the gradient of the flux-to-voltage characteristics, /spl delta/V//spl delta//spl Phi/, without hysteresis. A dc SQUID with a loop inductance L=30.5 pH, /spl beta//sub c/=0.72, and a 6 turn input coil demonstrated a non-distorted quasi-sinusoidal flux-to-voltage transfer function with an exceptionally large modulation depth of 140 /spl mu/V peak-to-peak. The spectral density of the magnetic flux noise was as low as 3.5/spl times/10/sup -7/ /spl Phi//sub 0//Hz/sup 1/2/ in the double stage configuration, measured at a temperature 4.2 K using direct read out electronics. In combination with an intermediary transformer, the current resolution of the SQUID is as low as 1.25 pA/Hz/sup 1/2/ with an input coil inductance of 100 nH.
The dynamics and noise of a dc superconducting quantum interference device (SQUID) with the McCumber parameter βc=2πR2IcC/Φ0 close to the unity (where Ic, R, C are the critical current, the shunt resistance, and the capacitance of the Josephson junctions comprising the SQUID, respectively, and Φ0=2.07×10−15 Wb is the magnetic flux quantum) integrated with a planar spiral input coil have been experimentally studied. The length of the spiral input coil was chosen to match its λ/4 microwave resonance frequency to the plasma resonance frequency of the SQUID. The input coil resonance enhances the overall quality factor Q of the Josephson oscillations in the SQUID and, as a result, increases the dynamic resistance Rd and the gradient of the flux-to-voltage characteristics ∂V/∂Φ without hysteresis. This relaxes the tolerance for the βc parameter, simplifies the technological process, and improves the yield of devices. A dc SQUID with loop inductance L=31.4 pH, βc=0.72, and a six turn input coil has demonstrated a nondistorted quasisinusoidal flux-to-voltage transfer function with an exceptionally large modulation depth of approximately 140 μV peak-to-peak. A spectral density of the intrinsic magnetic flux noise as low as 3.5×10−7 Φ0/Hz1/2 has been measured in the double stage configuration at a temperature of 4.2 K using direct read-out electronics. This corresponds to the intrinsic energy resolution of ε=12.5h. In combination with an intermediary transformer, the current resolution of the SQUID is as low as 1.25 pA/Hz1/2 with an input coil inductance of 58 nH. The coupled energy resolution is εc=45h in the white noise region.
It is known that SQUID has three important parameters, namely, Stewart-McCumber parameterβC, Screening parameterβLand thermal noise parameterΓ. They play a very important role in SQUID performance, especiallyβC. Recently, researchers extended the SQUID operating area toβc > 1 due to a large noise parameterΓin experiments. WhenβC> 1, SQUID exhibits a large flux-voltage transfer coefficient∂V/∂Φ, which is beneficial in reducing the noise contribution of the readout circuitδΦe. From the simulation results, we found that whenβC>1, SQUID produces a larger∂V/∂Φ thanβC∂V/∂Φ increases with the decrease ofβL. In order to further verify our findings, we selected two groups of SQUIDs for experiments (βCβC> 1), by changing the value of the shunt resistance on the Josephson junction to adjust the value of changingβC, and then we observe the value of∂V/∂Φ. Finally, we find that whenβL∂V/∂Φ of SQUID increases whileβCincreasing. A large∂V/∂Φ will help us to obtain an optimal SQUID measure system.
We experimentally studied two important parameters of helium-cooled superconducting quantum interference devices (SQUIDs) in the voltage bias mode: the dynamic resistance Rd and the flux-to-current transfer coefficient ∂i/∂Φ, with different junction shunt resistors RJ. We investigated a voltage-biased SQUID using the direct readout current-to-voltage converter scheme involving an operational amplifier. At higher RJ, the flux-to-voltage conversion coefficient ∂V/∂Φ becomes sufficiently large to effectively suppress the room-temperature amplifier's noise without any need for additional feedback circuits. The McCumber parameter limits the rise of ∂V/∂Φ. We discuss the performance of voltage-biased SQUIDs at different effective McCumber parameters.