Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

现代测量与实验室管理

Progresses of NIM Laser-cooled Cesium Fountain Time/Frequency Standard in 2000

Tian Li

Published Jan 1, 2001• 0 citations
OpenAlex

Abstract

In this paper we reported recent progresses on construction of the “NIM laser cooling\|Cs fountain” apparatus targeting as Chinese new generation time/frequency primary standard:loading and cooling of Cs atoms form MOT transferred to OM was realized;Cs fluorescence TOF signal with S/N40 recorded;atoms were cooled to (10~20)μK with post\|cooling;and Cs atom cloud were obtained using OM directly.We also gave discussions on results of the experiments mentioned above.

Related papers

Progress on the construction of an atomic cesium fountain at NIM

Tianchu Li, Mingshou Li, Huang Bingying +2 more

An atomic cesium fountain has been designed for a new primary standard of frequency in China. Cold atomic clouds collected in the magneto-optical trap (MOT) were previously reported (1995). To further improve the performance of the MOT we have optimized the laser-optical system and operation of the MOT. Some optical elements were replaced with new ones with better quality; frequency stabilization of lasers and arrangement of the optical system was modified; and polarization maintaining (PM) optical fibers were adopted to transfer lights from the optical system to MOT. We also installed the fluorescence detecting - amplifying assembles to take the time of flight (TOF) measurement of the cold atoms.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Nov 13, 2002•1 citation

Design and preliminary results of NIM cesium fountain primary frequency standard

Wang Liji, Wu Changhua, Huang Bingying +3 more

We have designed and constructed a cesium fountain as our new generation primary frequency standard. Serial performance measurements of components and assemblies are finished. A cold atomic cloud with diameter 1.5 mm and temperature /spl les/150 /spl mu/K has been observed in a magneto-optical trap set-up. It is used to obtain the optical molasses designed for the fountain clock.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Jan 22, 2003•1 citation

Experiments and Considerations of Realizing Cold Cesium Atomic 74 cm Fountain

Tianchu Li

The realization of 74 cm fountain of atomic clouds, obtaining fluorescence signal of time of flight with S/N~200, on NIM4# laser cooling - Cs atomic fountain clock is described. The improvements concerning launching - falling - signal detection are introduced, launching parameters listed, the fountain experiments are reported, and some preliminary discussions given.

Jiliang xuebao•Jan 1, 2003•0 citations

Progress towards a laser-cooled cesium atomic fountain frequency standard at NIST, Gaithersburg

William M. Klipstein, Christopher R. Ekstrom, S. L. Rolston +1 more

We report here on progress towards the realization of an atomic frequency standard using a fountain of laser cooled cesium atoms. We have recently observed Ramsey fringes on the 9.2 GHz clock transition and have begun preliminary work aimed at characterizing our fountain. This paper describes briefly the apparatus, discusses our current work and near-term directions. We conclude with a brief discussion of a laser system being built to realize two-dimensional Raman cooling or Raman velocity selection for cooling below the single photon recoil limit. This system will be used either in our fountain or in a cold-atom clock to be flown on the International Space Station.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Nov 27, 2002•2 citations

Article

Marie-Claude Gagné, J.-S. Boulanger, R J W Douglas

The accelerated development of laser methods for manipulating the internal state and motion of atoms, and the recent primary evaluation in France of a cesium frequency standard using cold atoms in an atomic fountain configuration, allow the frontiers of time metrology, accuracy, and stability to be pushed near parts in the 1016 level, a factor of 100 over the present primary laboratory clocks. These positive results revived the development of more accurate cesium atomic clocks, and the Institute of National Measurement Standards (INMS), of the National Research Council of Canada (NRC) is undertaking a cesium-fountain project aimed at reaching these new levels of accuracy and stability. This paper reviews its present status. To appreciate the considerable impact of cold atoms in time and frequency metrology, we begin by recalling the background principles of traditional cesium frequency standards, their typical performance and main limitations. After introducing the important theoretical results essential to understanding the techniques of laser cooling and magneto-optical trapping, we focus on describing the characterization and control of our magneto-optical trap (MOT) and report the parameters that allow us to fill the trap with a few million atoms in less than a second and cool them to a temperature lower than 5 muK using optical molasses. We will describe the specifics of our cesium-fountain prototype, which operates with a 2-dimensional moving molasses. This special configuration is applicable for multipulse operation of the fountain, which can greatly relax the local oscillator requirements for time keeping. Finally, progress toward our objective of launching cooled atoms, at a rate of one ensemble per second, at speeds of 7 m/s, for a fountain with an interrogation time of about 1 s, will be analysed.PACS Nos.: 06.20, 06.30, and 32.80P

Canadian Journal of Physics•Aug 1, 1998•0 citations

Work towards an atomic fountain clock at Peking University

Yimin Li, Jidong Hou, Junxian Fu +3 more

Cesium atomic fountain clock is the quantum frequency standard with very high accuracy. Research on laser cooling and trapping of cesium atom at Peking University began in 1993. A cesium atomic fountain frequency standard is being developed. A magneto-optical trap with some 108 trapped atoms and an optical molasses with the cold atoms of the temperature of 10/spl mu/K have been achieved previously. The device has been carefully designed and is under construction. It is composed of two main parts: vacuum system and laser system. The article describes the apparatus and presents a brief introduction to some considerations on the atomic clock.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Nov 27, 2002•0 citations
In this paper we reported recent progresses on construction of the “NIM laser cooling|Cs fountain” apparatus targeting as Chinese new generation time/frequency primary standard:loading and cooling of Cs atoms form MOT transferred to OM was realized;Cs fluorescence TOF signal with S/N40 recorded;atoms were cooled to (10~20)μK with post|cooling;and Cs atom cloud were obtained using OM directly.We also gave discussions on results of the experiments mentioned above.
An atomic cesium fountain has been designed for a new primary standard of frequency in China. Cold atomic clouds collected in the magneto-optical trap (MOT) were previously reported (1995). To further improve the performance of the MOT we have optimized the laser-optical system and operation of the MOT. Some optical elements were replaced with new ones with better quality; frequency stabilization of lasers and arrangement of the optical system was modified; and polarization maintaining (PM) optical fibers were adopted to transfer lights from the optical system to MOT. We also installed the fluorescence detecting - amplifying assembles to take the time of flight (TOF) measurement of the cold atoms.
We report here on progress towards the realization of an atomic frequency standard using a fountain of laser cooled cesium atoms. We have recently observed Ramsey fringes on the 9.2 GHz clock transition and have begun preliminary work aimed at characterizing our fountain. This paper describes briefly the apparatus, discusses our current work and near-term directions. We conclude with a brief discussion of a laser system being built to realize two-dimensional Raman cooling or Raman velocity selection for cooling below the single photon recoil limit. This system will be used either in our fountain or in a cold-atom clock to be flown on the International Space Station.
The accelerated development of laser methods for manipulating the internal state and motion of atoms, and the recent primary evaluation in France of a cesium frequency standard using cold atoms in an atomic fountain configuration, allow the frontiers of time metrology, accuracy, and stability to be pushed near parts in the 1016 level, a factor of 100 over the present primary laboratory clocks. These positive results revived the development of more accurate cesium atomic clocks, and the Institute of National Measurement Standards (INMS), of the National Research Council of Canada (NRC) is undertaking a cesium-fountain project aimed at reaching these new levels of accuracy and stability. This paper reviews its present status. To appreciate the considerable impact of cold atoms in time and frequency metrology, we begin by recalling the background principles of traditional cesium frequency standards, their typical performance and main limitations. After introducing the important theoretical results essential to understanding the techniques of laser cooling and magneto-optical trapping, we focus on describing the characterization and control of our magneto-optical trap (MOT) and report the parameters that allow us to fill the trap with a few million atoms in less than a second and cool them to a temperature lower than 5 muK using optical molasses. We will describe the specifics of our cesium-fountain prototype, which operates with a 2-dimensional moving molasses. This special configuration is applicable for multipulse operation of the fountain, which can greatly relax the local oscillator requirements for time keeping. Finally, progress toward our objective of launching cooled atoms, at a rate of one ensemble per second, at speeds of 7 m/s, for a fountain with an interrogation time of about 1 s, will be analysed.PACS Nos.: 06.20, 06.30, and 32.80P
Cesium atomic fountain clock is the quantum frequency standard with very high accuracy. Research on laser cooling and trapping of cesium atom at Peking University began in 1993. A cesium atomic fountain frequency standard is being developed. A magneto-optical trap with some 108 trapped atoms and an optical molasses with the cold atoms of the temperature of 10/spl mu/K have been achieved previously. The device has been carefully designed and is under construction. It is composed of two main parts: vacuum system and laser system. The article describes the apparatus and presents a brief introduction to some considerations on the atomic clock.