Faraday magnetic resonance imaging of Bose-Einstein condensates

M. Jasperse

Published Jan 1, 2017• 2 citations
Publisher

Abstract

This thesis presents a novel magnetic resonance imaging (MRI) technique for spinor Bose-Einstein condensates (BEC) with the paramagnetic Faraday effect. This quantum-photon interface couples the spin of the BEC to the polarisation of an off-resonant laser, which in a magnetic field gradient allows a 1D density profile of the BEC to be reconstructed. As opposed to conventional imaging techniques that are destructive or diffraction limited, this technique is minimally destructive to the BEC and not diffraction limited. Multishot in situ imaging of a single condensate is therefore possible, paving the way for time-resolved studies and 2D/3D reconstructions. A theoretical model for Faraday imaging is developed using the tensor polarisability formalism for the atom-light interaction, and the signal-to-noise ratio is derived. Resolution limits induced by Stern-Gerlach separation are considered, encouraging rapid measurements with strong magnetic field gradients. Analysing the trapping potential reveals that the `magic-zero' wavelength 790nm produces no dipole force and enables a tightly focused probe laser to be used without perturbing the trap. Polarisation-maintaining fibers were seen to impart large fluctuations depending on the incident polarisation, which were minimised. The broad diode laser emission background is seen to reduce the lifetime of the BEC, which was corrected with an interference filter. Short-time Fourier transforms are used to process the photodetected signal, showing the evolution of the polarisation rotation frequency and amplitude. Frequency-modulation is observed at the power line frequency, corresponding to magnetic field fluctuations induced by nearby equipment. Birefringence of optical elements results in elliptical polarisation of the probe and an effective magnetic field, which is cancelled using a quarter-waveplate. The quadratic Zeeman effect causes rapid amplitude modulation, and is eliminated by applying a microwave dressing field. Radiative spin echo is achieved in a magnetic field gradient, proving that dephasing is coherent, and that multishot imaging possible. Magnetic resonance imaging (MRI) is performed on a partially-evaporated atom cloud, distinguishing the thermal and condensed fractions. A split dipole trap is used to create two spatially separated BECs, which are individually resolved during MRI. The resolution is only limited by the strength of the applied magnetic field gradient, and is not subject to the diffraction limit. Custom coils will enable MRI of condensates at the sub-micron scale.

DOI
10.4225/03/58b64dbe466ce

Related papers

Spinor Bose-Einstein condensates in magnetic field gradients

A. A. Wood

Spinor Bose-Einstein condensates (BECs) are multi-component superfluids with magnetic interactions, formed from dilute gases of atoms in the Zeeman sublevels mF of a single hyperfine ground state F. Spinor BECs are inherently magnetic quantum objects, and exhibit a multitude of features such as spin domains, magnon excitations, and distinct magnetic phases. At the heart of the magnetic nature of a spinor BEC is the spin-dependent collisional interaction c, which determines the overall magnetic behaviour of the superfluid. In conjunction with the quadratic Zeeman shift q, the magnitude and sign of c give rise to an intricate magnetic phase diagram. The magnetic phase of a spinor BEC is tunable, and c and q are the knobs. In addition to realising quantum simulators of magnetism, spinor BECs are also precise magnetic sensors. Atomic magnetometry measures the Larmor precession frequency of atoms, which is proportional to the magnetic field strength. The sensitivity of an atomic magnetometer is principally dependent on the duration of the measurement (interrogation time) and number of atoms participating in the measurement. BECs are highly suitable as atomic magnetometers, allowing for long interrogation times and high atomic density, with microscopic sensor volumes. The latter is an important consideration, as measurement of small magnetic sources demand equally microscopic sensors. Established forms of magnetometry (such as warm vapour magnetometers) use large sensing volumes and are not trivially miniaturised. The exquisite sensitivity of a spinor BEC to magnetic fields becomes a liability when one studies low energy (~ 1 Hz) spinor physics over long evolution times (100 ms) in a typical laboratory environment. To first order, the spin-collisional interaction is independent of the magnetic field. However, spatially inhomogeneous magnetic fields are problematic, exerting mechanical forces on the magnetically sensitive spin components, suppressing spin collisions and possibly introducing relaxation mechanisms that confound the observation of intrinsic equilibration. Precise characterisation of magnetic field gradients and their cancellation is thus of paramount importance. In this thesis, the interaction of a spinor BEC with its environment is studied. The construction, operation and optimisation of a BEC machine is described in detail, as well as the quantum state preparation and control techniques used. Spin-mixing collisions were studied by observing population oscillations, the characteristic hallmark of such coherent phenomena. The observed population dynamics showed strong evidence of the deleterious effects of magnetic field gradients. A series of experiments were performed using spin-echo pulse sequences to decouple the evolving spinor condensate from the inhomogeneous magnetic environment with encouraging results, but which posed further questions. The fidelity of spin-echo pulses in the strong radiative coupling regime was also studied. Spinor condensates were then employed as sensitive magnetometers to characterise the magnetic landscape they inhabit. A new method of measuring magnetic field gradients was developed, using a pair of spinor BECs separated in space that are simultaneously addressed by a Ramsey interferometry sequence. Combined with a re-orientable magnetic bias field, the resulting gradiometer was used to measure the magnetic field gradient tensor in vacuo. This scheme can be extended to realise a high-precision vector co-magnetometer, with spatiotemporal sensitivity comparable to established forms of magnetometry. Vector light shifts (VLSs) are optically-induced energy shifts that result in effective magnetic fields, which in our case originate from the laser beams used to trap the atoms. The VLS vanishes for purely linearly polarised light, which is experimentally difficult to obtain in vacuo. Small elliptical polarisation imperfections originating from birefringent optics and the glass vacuum cell result in a non-zero shift that contaminates magnetometry measurements. The VLS is spatially varying due to the intensity gradient of the trapping light. Due to gravitational sag of the trapping potential, the spatial variation of the VLS is accentuated, resulting in an effective magnetic field gradient that contributes to dephasing and component separation. The simultaneous Ramsey interferometry experiments are then adapted to measure the VLS-induced Zeeman shift and diagnose its elimination. Up to 99.96% of the VLS is eliminated using this method, and extensions to the technique are described.

•Jan 1, 2017•0 citations

Precise engineering of the Bose-Einstein condensate wavefunction using magnetic resonance control

L. M. Starkey

To engineer the wavefunction of a Bose–Einstein condensate is to exert control over both the density and phase of the Bose–Einstein condensate order parameter. Having the ability to engineer the condensate order parameter down to the smallest length scale relevant to condensate dynamics—the healing length scale—would enable the study of new combinations of topological defects and may pave the way to using Bose–Einstein condensates as versatile, precise quantum simulators. In this thesis, we present a new wavefunction engineering technique which reaches the sub-optical healing length scale. Influenced by magnetic resonance imaging, we name this technique magnetic resonance control. This technique uses time-varying coupling between internal spin states of a spinor Bose–Einstein condensate within a magnetic field gradient to address spatial regions of the condensate, enabling control over both the phase and the density of the condensate order parameter down to the healing length scale. Techniques already exist to engineer condensate wavefunctions, but not with such a fine degree of control. These techniques primarily rely on either the intensity variation of a laser beam, which limits the resolution to the diffraction limit (larger than the typically sub-optical healing length scale), or the adiabatic inversion of a magnetic trapping potential, which can not be easily changed to produce a variety of structures in the condensate wavefunction. To develop our magnetic resonance control technique, we simulate a spinor condensate in one dimension with time-dependent coupling between spin states and time-dependent external magnetic field gradients using the Gross–Pitaevskii equation. We show that magnetic resonance control can engineer a single black soliton using experimentally feasible parameters. A black soliton is an ideal target state to select for this demonstration because engineering such a state requires control over both the phase and density of the condensate with healing-length resolution. We demonstrate that magnetic resonance control can be extended to engineer more complicated target states by simulating the creation of multiple solitons in a condensate, with control over the initial positions and trajectories of the solitons. When magnetic resonance control is applied to Bose–Einstein condensates in the laboratory, it will be necessary to have an imaging system capable of resolving the fine structures created. As an alternative to high-cost, custom-manufactured lenses, and in-vacuum optical systems, I have designed and bench-tested an objective lens with a high numerical aperture (0.36) and a long working distance (35 mm) consisting of standard catalogue lenses. Using 780 nm light, suitable for imaging rubidium condensates, this objective can achieve a resolution of 1.3 μm across a diffraction-limited field of view of 360 μm through a 5 mm thick glass window of a science cell. By changing the spacing between the lens elements, this objective lens can compensate for the aberrations produced by a glass window up to 15 mm thick, and by changing the aperture size the objective becomes suitable for diffraction-limited monochromatic imaging on the D2 line of all the alkalis. Before performing proof-of-principle magnetic resonance control experiments on real Bose–Einstein condensates, we needed to construct an experimental apparatus capable of producing spinor Bose–Einstein condensates. In this thesis I summarise my main contributions to this group endeavour, including: constructing the ultra-high vacuum system; supervising the bakeout of our vacuum system; designing and aligning the optical systems to produce laser beams of different, tunable frequencies to trap, cool, and image rubidium gas; trapping a cloud of rubidium atoms in a magneto-optical trap; constructing laser beam shutters, photodetectors, and photodetector signal filters; and designing and constructing our side imaging and top imaging systems. Using our spinor Bose–Einstein condensate apparatus, I performed the first proof-of-principle magnetic resonance control experiments. With a pair of condensates side-by-side, separated by 200 μm, we can use magnetic resonance control to invert the spin of one condensate only, while leaving the other condensate unaffected. We anticipate magnetic resonance control being used in the laboratory to engineer the first black soliton in a Bose–Einstein condensate. Looking beyond solitons, magnetic resonance control could have applications to the field of magnon spintronics, and extending the technique to higher dimensions could enable the study of exotic topological defects such as spin knots in a quantum fluid.

•Jan 1, 2017•0 citations

Ultra-cold atomic magnetometry: realisation and test of a ⁸⁷Rb BEC for high-sensitivity magnetic field measurements

Michela Venturelli

The development of an experimental apparatus to produce Bose-Einstein condensates (BECs) of ⁸⁷Rb atoms and their application to magnetometry are discussed. Optical detection of atomic Larmor precession is a widely explored method for high-sensitivity measurements of magnetic fields. In this context, short laser/atom interaction time, atomic thermal diffusion and decoherence effects are among the main limitations. In this thesis, we overcome such problems by using spin-polarised ⁸⁷Rb ultra-cold atoms as the sensing element. After the atoms are polarised, a resonant pulse of radio-frequency excites Larmor precession, which is sensitive to external magnetic fields. By measuring the perturbations of the radio-frequency induced spin precession, information on the magnetic fields of interest. This is achieved by monitoring the polarisation plane’s rotation of a linearly polarised resonant laser probe. In the first part of this thesis, the building and optimisation of a laser-cooling set up to obtain a BEC in a hybrid trap is reported. In order to achieve the Phase Space Density (PSD) required for BEC, several different stages of trapping and cooling are necessary. Each phase has been implemented and optimised. The first step consists in the magneto-optical trap (MOT). Here a velocity dependent damping force and a spatially dependent confining force give the largest changes in PSD. Then atoms are loaded into a hybrid trap obtained by overlapping a quadrupole magnetic potential and a far detuned optical crossed dipole trap. The final stage for the condensation consists of forced evaporative cooling, both via magnetic and optical evaporation. In the second part of the thesis, a general overview of the principles of optical atomic magnetometry is provided and the advantages of using ultra-cold atoms with respect to conventional thermal vapours are discussed. The implementation, operation and a preliminary characterisation of the ultra-cold atom magnetometer are described along with the preliminary results collected. Finally, a plan for future improvements of its sensitivity is presented.

•Sep 28, 2018•0 citations

Multi-second magnetic coherence in a single domain spinor Bose–Einstein condensate

Silvana Palacios, Simon Coop, Pau Gomez +4 more

We describe a compact, robust and versatile system for studying the macroscopic spin dynamics in a spinor Bose–Einstein condensate. Condensates of are produced by all-optical evaporation in a 1560 nm optical dipole trap, using a non-standard loading sequence that employs an ancillary 1529 nm beam for partial compensation of the strong differential light-shift induced by the dipole trap itself. We use near-resonant Faraday rotation probing to non-destructively track the condensate magnetization, and demonstrate few-Larmor-cycle tracking with no detectable degradation of the spin polarization. In the ferromagnetic F = 1 ground state, we observe the spin orientation between atoms in the condensate is preserved, such that they precess all together like one large spin in the presence of a magnetic field. We characterize this dynamics in terms of the single-shot magnetic coherence times and , and observe them to be of several seconds, limited only by the residence time of the atoms in the trap. At the densities used, this residence is restricted only by one-body losses set by the vacuum conditions.

arXiv:1707.09607•New Journal of Physics•Feb 27, 2018•22 citations

Towards an imaging lattice for magnetically trapped atoms

E. Owen

The imaging of neutral atoms confined in an optical lattice has been demonstrated by a number of groups, resolving single fluorescing atoms in samples of hundreds of atoms. To obtain a high signal the atoms remain confined in the wells of a deep optical lattice whilst fluorescence excitation light is applied for high resolution imaging. In most cases, the excitation light frequency is chosen so that there is a concomitant laser cooling effect. In existing implementations of an imaging lattice the preceding manipulation stage has used optical trapping and manipulation. In this thesis I describe work towards applying this imaging lattice technique on a magnetic trapping apparatus, in particular for carrying out quantum simulation experiments. An introduction to the specific challenge of performing a quantum simulation of the fractional quantum Hall effect is given, with the link to and nature of the imaging lattice technique explained. The existing quantum-gas machine that has been developed to produce Bose-Einstein condensates of 87Rb in this work is then described, including the new optical lattice subsystem and the associated diode laser system. An auxiliary project to develop a servo-control system for frequencies that are several GHz away from an atomic reference is presented. We implement an optical lattice using laser light with a frequency detuning of -20 GHz below the D1-resonance line. The construction and geometry of the individual dipole trapping beams in combination with our existing apparatus is discussed as well as the alignment methods used. We confirm the presence of three independent 1D lattices through diffraction, and observe the decay of a BEC loaded into a lattice using absorption imaging. We observe good long-term alignment and operational stability of the optical lattice. This system will enable us to ultimately detect single fluorescing atoms in the optical lattice, following the application of excitation light co-propogating with lattice beams, via an imaging system with a moderate numerical aperture of 0:27.

•Jan 1, 2017•0 citations

Continuous Faraday measurement of spin precession without light shifts

M. Jasperse, Michael J. Kewming, S. N. Fischer +3 more

We describe a dispersive Faraday optical probe of atomic spin which performs a weak measurement of spin projection of a quantum gas continuously for more than one second. To date, focusing bright far-off-resonance probes onto quantum gases has proved invasive due to strong scalar and vector light shifts exerting dipole and Stern-Gerlach forces. We show that tuning the probe near the magic-zero wavelength at 790 nm between the fine-structure doublet of $^{87}\mathrm{Rb}$ cancels the scalar light shift, and careful control of polarization eliminates the vector light shift. Faraday rotations due to each fine-structure line reinforce at this wavelength, enhancing the signal-to-noise ratio for a fixed rate of probe-induced decoherence. Using this minimally invasive spin probe, we perform microscale atomic magnetometry at high temporal resolution. Spectrogram analysis of the Larmor precession signal of a single spinor Bose-Einstein condensate measures a time-varying magnetic field strength with 1 $\ensuremath{\mu}\mathrm{G}$ accuracy every 5 ms; or, equivalently, makes more than 200 successive measurements each at $10\phantom{\rule{0.16em}{0ex}}\mathrm{pT}/\sqrt{\mathrm{Hz}}$ sensitivity.

arXiv:1705.10965•Physical Review A•Dec 1, 2017•21 citations
This thesis presents a novel magnetic resonance imaging (MRI) technique for spinor Bose-Einstein condensates (BEC) with the paramagnetic Faraday effect. This quantum-photon interface couples the spin of the BEC to the polarisation of an off-resonant laser, which in a magnetic field gradient allows a 1D density profile of the BEC to be reconstructed. As opposed to conventional imaging techniques that are destructive or diffraction limited, this technique is minimally destructive to the BEC and not diffraction limited. Multishot in situ imaging of a single condensate is therefore possible, paving the way for time-resolved studies and 2D/3D reconstructions. A theoretical model for Faraday imaging is developed using the tensor polarisability formalism for the atom-light interaction, and the signal-to-noise ratio is derived. Resolution limits induced by Stern-Gerlach separation are considered, encouraging rapid measurements with strong magnetic field gradients. Analysing the trapping potential reveals that the `magic-zero' wavelength 790nm produces no dipole force and enables a tightly focused probe laser to be used without perturbing the trap. Polarisation-maintaining fibers were seen to impart large fluctuations depending on the incident polarisation, which were minimised. The broad diode laser emission background is seen to reduce the lifetime of the BEC, which was corrected with an interference filter. Short-time Fourier transforms are used to process the photodetected signal, showing the evolution of the polarisation rotation frequency and amplitude. Frequency-modulation is observed at the power line frequency, corresponding to magnetic field fluctuations induced by nearby equipment. Birefringence of optical elements results in elliptical polarisation of the probe and an effective magnetic field, which is cancelled using a quarter-waveplate. The quadratic Zeeman effect causes rapid amplitude modulation, and is eliminated by applying a microwave dressing field. Radiative spin echo is achieved in a magnetic field gradient, proving that dephasing is coherent, and that multishot imaging possible. Magnetic resonance imaging (MRI) is performed on a partially-evaporated atom cloud, distinguishing the thermal and condensed fractions. A split dipole trap is used to create two spatially separated BECs, which are individually resolved during MRI. The resolution is only limited by the strength of the applied magnetic field gradient, and is not subject to the diffraction limit. Custom coils will enable MRI of condensates at the sub-micron scale.
Spinor Bose-Einstein condensates (BECs) are multi-component superfluids with magnetic interactions, formed from dilute gases of atoms in the Zeeman sublevels mF of a single hyperfine ground state F. Spinor BECs are inherently magnetic quantum objects, and exhibit a multitude of features such as spin domains, magnon excitations, and distinct magnetic phases. At the heart of the magnetic nature of a spinor BEC is the spin-dependent collisional interaction c, which determines the overall magnetic behaviour of the superfluid. In conjunction with the quadratic Zeeman shift q, the magnitude and sign of c give rise to an intricate magnetic phase diagram. The magnetic phase of a spinor BEC is tunable, and c and q are the knobs. In addition to realising quantum simulators of magnetism, spinor BECs are also precise magnetic sensors. Atomic magnetometry measures the Larmor precession frequency of atoms, which is proportional to the magnetic field strength. The sensitivity of an atomic magnetometer is principally dependent on the duration of the measurement (interrogation time) and number of atoms participating in the measurement. BECs are highly suitable as atomic magnetometers, allowing for long interrogation times and high atomic density, with microscopic sensor volumes. The latter is an important consideration, as measurement of small magnetic sources demand equally microscopic sensors. Established forms of magnetometry (such as warm vapour magnetometers) use large sensing volumes and are not trivially miniaturised. The exquisite sensitivity of a spinor BEC to magnetic fields becomes a liability when one studies low energy (~ 1 Hz) spinor physics over long evolution times (100 ms) in a typical laboratory environment. To first order, the spin-collisional interaction is independent of the magnetic field. However, spatially inhomogeneous magnetic fields are problematic, exerting mechanical forces on the magnetically sensitive spin components, suppressing spin collisions and possibly introducing relaxation mechanisms that confound the observation of intrinsic equilibration. Precise characterisation of magnetic field gradients and their cancellation is thus of paramount importance. In this thesis, the interaction of a spinor BEC with its environment is studied. The construction, operation and optimisation of a BEC machine is described in detail, as well as the quantum state preparation and control techniques used. Spin-mixing collisions were studied by observing population oscillations, the characteristic hallmark of such coherent phenomena. The observed population dynamics showed strong evidence of the deleterious effects of magnetic field gradients. A series of experiments were performed using spin-echo pulse sequences to decouple the evolving spinor condensate from the inhomogeneous magnetic environment with encouraging results, but which posed further questions. The fidelity of spin-echo pulses in the strong radiative coupling regime was also studied. Spinor condensates were then employed as sensitive magnetometers to characterise the magnetic landscape they inhabit. A new method of measuring magnetic field gradients was developed, using a pair of spinor BECs separated in space that are simultaneously addressed by a Ramsey interferometry sequence. Combined with a re-orientable magnetic bias field, the resulting gradiometer was used to measure the magnetic field gradient tensor in vacuo. This scheme can be extended to realise a high-precision vector co-magnetometer, with spatiotemporal sensitivity comparable to established forms of magnetometry. Vector light shifts (VLSs) are optically-induced energy shifts that result in effective magnetic fields, which in our case originate from the laser beams used to trap the atoms. The VLS vanishes for purely linearly polarised light, which is experimentally difficult to obtain in vacuo. Small elliptical polarisation imperfections originating from birefringent optics and the glass vacuum cell result in a non-zero shift that contaminates magnetometry measurements. The VLS is spatially varying due to the intensity gradient of the trapping light. Due to gravitational sag of the trapping potential, the spatial variation of the VLS is accentuated, resulting in an effective magnetic field gradient that contributes to dephasing and component separation. The simultaneous Ramsey interferometry experiments are then adapted to measure the VLS-induced Zeeman shift and diagnose its elimination. Up to 99.96% of the VLS is eliminated using this method, and extensions to the technique are described.
To engineer the wavefunction of a Bose–Einstein condensate is to exert control over both the density and phase of the Bose–Einstein condensate order parameter. Having the ability to engineer the condensate order parameter down to the smallest length scale relevant to condensate dynamics—the healing length scale—would enable the study of new combinations of topological defects and may pave the way to using Bose–Einstein condensates as versatile, precise quantum simulators. In this thesis, we present a new wavefunction engineering technique which reaches the sub-optical healing length scale. Influenced by magnetic resonance imaging, we name this technique magnetic resonance control. This technique uses time-varying coupling between internal spin states of a spinor Bose–Einstein condensate within a magnetic field gradient to address spatial regions of the condensate, enabling control over both the phase and the density of the condensate order parameter down to the healing length scale. Techniques already exist to engineer condensate wavefunctions, but not with such a fine degree of control. These techniques primarily rely on either the intensity variation of a laser beam, which limits the resolution to the diffraction limit (larger than the typically sub-optical healing length scale), or the adiabatic inversion of a magnetic trapping potential, which can not be easily changed to produce a variety of structures in the condensate wavefunction. To develop our magnetic resonance control technique, we simulate a spinor condensate in one dimension with time-dependent coupling between spin states and time-dependent external magnetic field gradients using the Gross–Pitaevskii equation. We show that magnetic resonance control can engineer a single black soliton using experimentally feasible parameters. A black soliton is an ideal target state to select for this demonstration because engineering such a state requires control over both the phase and density of the condensate with healing-length resolution. We demonstrate that magnetic resonance control can be extended to engineer more complicated target states by simulating the creation of multiple solitons in a condensate, with control over the initial positions and trajectories of the solitons. When magnetic resonance control is applied to Bose–Einstein condensates in the laboratory, it will be necessary to have an imaging system capable of resolving the fine structures created. As an alternative to high-cost, custom-manufactured lenses, and in-vacuum optical systems, I have designed and bench-tested an objective lens with a high numerical aperture (0.36) and a long working distance (35 mm) consisting of standard catalogue lenses. Using 780 nm light, suitable for imaging rubidium condensates, this objective can achieve a resolution of 1.3 μm across a diffraction-limited field of view of 360 μm through a 5 mm thick glass window of a science cell. By changing the spacing between the lens elements, this objective lens can compensate for the aberrations produced by a glass window up to 15 mm thick, and by changing the aperture size the objective becomes suitable for diffraction-limited monochromatic imaging on the D2 line of all the alkalis. Before performing proof-of-principle magnetic resonance control experiments on real Bose–Einstein condensates, we needed to construct an experimental apparatus capable of producing spinor Bose–Einstein condensates. In this thesis I summarise my main contributions to this group endeavour, including: constructing the ultra-high vacuum system; supervising the bakeout of our vacuum system; designing and aligning the optical systems to produce laser beams of different, tunable frequencies to trap, cool, and image rubidium gas; trapping a cloud of rubidium atoms in a magneto-optical trap; constructing laser beam shutters, photodetectors, and photodetector signal filters; and designing and constructing our side imaging and top imaging systems. Using our spinor Bose–Einstein condensate apparatus, I performed the first proof-of-principle magnetic resonance control experiments. With a pair of condensates side-by-side, separated by 200 μm, we can use magnetic resonance control to invert the spin of one condensate only, while leaving the other condensate unaffected. We anticipate magnetic resonance control being used in the laboratory to engineer the first black soliton in a Bose–Einstein condensate. Looking beyond solitons, magnetic resonance control could have applications to the field of magnon spintronics, and extending the technique to higher dimensions could enable the study of exotic topological defects such as spin knots in a quantum fluid.
The development of an experimental apparatus to produce Bose-Einstein condensates (BECs) of ⁸⁷Rb atoms and their application to magnetometry are discussed. Optical detection of atomic Larmor precession is a widely explored method for high-sensitivity measurements of magnetic fields. In this context, short laser/atom interaction time, atomic thermal diffusion and decoherence effects are among the main limitations. In this thesis, we overcome such problems by using spin-polarised ⁸⁷Rb ultra-cold atoms as the sensing element. After the atoms are polarised, a resonant pulse of radio-frequency excites Larmor precession, which is sensitive to external magnetic fields. By measuring the perturbations of the radio-frequency induced spin precession, information on the magnetic fields of interest. This is achieved by monitoring the polarisation plane’s rotation of a linearly polarised resonant laser probe. In the first part of this thesis, the building and optimisation of a laser-cooling set up to obtain a BEC in a hybrid trap is reported. In order to achieve the Phase Space Density (PSD) required for BEC, several different stages of trapping and cooling are necessary. Each phase has been implemented and optimised. The first step consists in the magneto-optical trap (MOT). Here a velocity dependent damping force and a spatially dependent confining force give the largest changes in PSD. Then atoms are loaded into a hybrid trap obtained by overlapping a quadrupole magnetic potential and a far detuned optical crossed dipole trap. The final stage for the condensation consists of forced evaporative cooling, both via magnetic and optical evaporation. In the second part of the thesis, a general overview of the principles of optical atomic magnetometry is provided and the advantages of using ultra-cold atoms with respect to conventional thermal vapours are discussed. The implementation, operation and a preliminary characterisation of the ultra-cold atom magnetometer are described along with the preliminary results collected. Finally, a plan for future improvements of its sensitivity is presented.
We describe a compact, robust and versatile system for studying the macroscopic spin dynamics in a spinor Bose–Einstein condensate. Condensates of are produced by all-optical evaporation in a 1560 nm optical dipole trap, using a non-standard loading sequence that employs an ancillary 1529 nm beam for partial compensation of the strong differential light-shift induced by the dipole trap itself. We use near-resonant Faraday rotation probing to non-destructively track the condensate magnetization, and demonstrate few-Larmor-cycle tracking with no detectable degradation of the spin polarization. In the ferromagnetic F = 1 ground state, we observe the spin orientation between atoms in the condensate is preserved, such that they precess all together like one large spin in the presence of a magnetic field. We characterize this dynamics in terms of the single-shot magnetic coherence times and , and observe them to be of several seconds, limited only by the residence time of the atoms in the trap. At the densities used, this residence is restricted only by one-body losses set by the vacuum conditions.
The imaging of neutral atoms confined in an optical lattice has been demonstrated by a number of groups, resolving single fluorescing atoms in samples of hundreds of atoms. To obtain a high signal the atoms remain confined in the wells of a deep optical lattice whilst fluorescence excitation light is applied for high resolution imaging. In most cases, the excitation light frequency is chosen so that there is a concomitant laser cooling effect. In existing implementations of an imaging lattice the preceding manipulation stage has used optical trapping and manipulation. In this thesis I describe work towards applying this imaging lattice technique on a magnetic trapping apparatus, in particular for carrying out quantum simulation experiments. An introduction to the specific challenge of performing a quantum simulation of the fractional quantum Hall effect is given, with the link to and nature of the imaging lattice technique explained. The existing quantum-gas machine that has been developed to produce Bose-Einstein condensates of 87Rb in this work is then described, including the new optical lattice subsystem and the associated diode laser system. An auxiliary project to develop a servo-control system for frequencies that are several GHz away from an atomic reference is presented. We implement an optical lattice using laser light with a frequency detuning of -20 GHz below the D1-resonance line. The construction and geometry of the individual dipole trapping beams in combination with our existing apparatus is discussed as well as the alignment methods used. We confirm the presence of three independent 1D lattices through diffraction, and observe the decay of a BEC loaded into a lattice using absorption imaging. We observe good long-term alignment and operational stability of the optical lattice. This system will enable us to ultimately detect single fluorescing atoms in the optical lattice, following the application of excitation light co-propogating with lattice beams, via an imaging system with a moderate numerical aperture of 0:27.
We describe a dispersive Faraday optical probe of atomic spin which performs a weak measurement of spin projection of a quantum gas continuously for more than one second. To date, focusing bright far-off-resonance probes onto quantum gases has proved invasive due to strong scalar and vector light shifts exerting dipole and Stern-Gerlach forces. We show that tuning the probe near the magic-zero wavelength at 790 nm between the fine-structure doublet of 87Rb^{87}\mathrm{Rb}87Rb cancels the scalar light shift, and careful control of polarization eliminates the vector light shift. Faraday rotations due to each fine-structure line reinforce at this wavelength, enhancing the signal-to-noise ratio for a fixed rate of probe-induced decoherence. Using this minimally invasive spin probe, we perform microscale atomic magnetometry at high temporal resolution. Spectrogram analysis of the Larmor precession signal of a single spinor Bose-Einstein condensate measures a time-varying magnetic field strength with 1 $\ensuremath{\mu}\mathrm{G}$ accuracy every 5 ms; or, equivalently, makes more than 200 successive measurements each at 10pT/Hz10\phantom{\rule{0.16em}{0ex}}\mathrm{pT}/\sqrt{\mathrm{Hz}}10pT/Hz​ sensitivity.