Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Springer series in optical sciences/SPringer series in optical sciences

Nonlinear Doppler-free Spectroscopy of Gas-Phase Atoms at Glass-Vapor Interfaces

S. Le Boiteux, Pierre Simoneau, Daniel Bloch, M. Ducloy

Published Jan 1, 1987• 1 citation
Publisher
DOI
10.1007/978-3-540-47973-4_78

Related papers

Evanescent wave spectroscopy of sublevel resonances near a glass/vapor interface

Dieter Suter, Jérǒme Äbersold, J. Mlynek

Optics Communications•Aug 1, 1991•15 citations

DOPPLER-FREE SPECTROSCOPY BY LINEAR SELECTIVE REFLECTION AT GLASS/Cs-VAPOR INTERFACE

Marcos Oriá, Daniel Bloch, M. Ducloy

Laser Spectroscopy•Jan 1, 1989•1 citation

Theory of Doppler-free spectroscopy with λ-thick vapor cells

Aleksandr N. Naumov, Alexey A Podshivalov, Konstantin N. Drabovich +2 more

Physics Letters A•Oct 1, 2001•4 citations

Doppler-free spectroscopy using magnetically induced dichroism of atomic vapor: a new scheme for laser frequency locking

T. Petelski, M. Fattori, Giacomo Lamporesi +2 more

The European Physical Journal D•Feb 1, 2003•87 citations

Nonlinear Doppler-free spectroscopy of atoms near a surface

Pierre Simoneau, S. Le Boiteux, C. De Araujo +2 more

Up to now, Doppler-free nonlinear spectroscopy has been applied to atoms inside a gas medium (volume spectroscopy). We have extended these methods to atoms in the vicinity of a surface. The basic principle consists of monitoring reflectivity changes produced when a laser beam, incident on a glass–vapor interface, is brought into resonance with an atomic transition. For Doppler-free spectroscopy, two counterpropagating beams are used to operate velocity selection. If these two beams are under normal incidence in the glass—velocity selection perpendicular to the surface—one observes saturated dispersion (selective reflection sensitive to the real index). For incidence angles in the glass (prism) larger than the critical angle (total internal reflection), a standing evanescent wave is produced in the gas (velocity selection along the surface), and saturated absorption is detected. Experimental demonstration was performed on the Na resonance line; high sensitivity (10−4 relative reflectivity change) and spectral resolution as good as 20 MHz were obtained. The main limitation to better resolution comes from the short atomic transit time in the evanescent wave (typical extension ~λ). Relevant applications of these techniques should also concern the diagnostics of optically thick media, as analysis of interaction between gas-phase atoms and the surface, notably atom–wall collisions, and modification of the spontaneous emission characteristics.

International Laser Science Conference•Jan 1, 1986•0 citations

Doppler-free spectroscopy at a glass-vapour interface by saturated selective reflection at near normal incidence

S. Le Boiteux, Pierre Simoneau, Daniel Bloch +1 more

Doppler-free spectra of gas phase atoms near a glass-vapour interface are obtained by monitoring the reflection of a probe beam-instead of its transmission-in three-level saturation spectroscopy. Experiments performed on the 3S-3P-4D cascade system of Na have allowed the authors to monitor two-photon-induced saturated dispersion of Na atoms.

Journal of Physics B Atomic and Molecular Physics•Mar 14, 1987•22 citations
Up to now, Doppler-free nonlinear spectroscopy has been applied to atoms inside a gas medium (volume spectroscopy). We have extended these methods to atoms in the vicinity of a surface. The basic principle consists of monitoring reflectivity changes produced when a laser beam, incident on a glass–vapor interface, is brought into resonance with an atomic transition. For Doppler-free spectroscopy, two counterpropagating beams are used to operate velocity selection. If these two beams are under normal incidence in the glass—velocity selection perpendicular to the surface—one observes saturated dispersion (selective reflection sensitive to the real index). For incidence angles in the glass (prism) larger than the critical angle (total internal reflection), a standing evanescent wave is produced in the gas (velocity selection along the surface), and saturated absorption is detected. Experimental demonstration was performed on the Na resonance line; high sensitivity (10−4 relative reflectivity change) and spectral resolution as good as 20 MHz were obtained. The main limitation to better resolution comes from the short atomic transit time in the evanescent wave (typical extension ~λ). Relevant applications of these techniques should also concern the diagnostics of optically thick media, as analysis of interaction between gas-phase atoms and the surface, notably atom–wall collisions, and modification of the spontaneous emission characteristics.