Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Optics and Precision Engineering

Active magnetic compensation of spin-exchange-relaxation-free atomic magnetometer

楚中毅 CHU Zhong-yi, 孙晓光 SUN Xiao-guang, 万双爱 WAN Shuang-ai, 房建成 FANG Jian-cheng

Published Jan 1, 2014• 2 citations
Publisher
DOI
10.3788/ope.20142207.1808

Related papers

Experiment on Active Magnetic Compensation of Atomic Magnetometer for Space Exploration

Chu Zhongy

The spin-exchange-relaxation-free(SERF)atomic magnetometer with ultrahigh sensitive becomes the most effective measurement to analyze the component of the planet in space exploration.In order to improve the sensitivity of the SERF atomic magnetometer,we must avoid the influence on the SERF regime disturbed by environment magnetic field.In this paper we design an active compensation system based on in-situ magnetic measurement to compensate the magnetic disturbance.Firstly,we get the three-axis magnetic field information according to the measurement of pop-laser,then control the current of coil to generate a magnetic field which is opposite and equal to the disturbance,to keep the SERF regime.Finally,we validat the method with the atomic magnetometer experimental setup.The result shows that compared with the manual compensation method,the system can track the magnetic compensation point in real time,reduce the signal noise and compensate the magnetic disturbance successfully,validating the efficiency of the active compensation system and establishing the technique foundation of the production.

Acta Aeronautica Et Astronautica Sinica•Jan 1, 2014•4 citations

Signal-enhanced spin-exchange relaxation-free atomic magnetometer

Cao Li, Junjian Tang, Yaohua Zhang +4 more

Sensors and Actuators A Physical•Feb 16, 2023•24 citations

In-situ magnetic field compensation for zero-field NMOR atomic magnetometer

Changhao Zhang, Jiali Liu, Xin Hui Zhao +4 more

Sensors and Actuators A Physical•Mar 10, 2025•9 citations

In situ triaxial magnetic field compensation for the spin-exchange-relaxation-free atomic magnetometer

Jiancheng Fang, Jie Qin

The spin-exchange-relaxation-free (SERF) atomic magnetometer is an ultra-high sensitivity magnetometer, but it must be operated in a magnetic field with strength less than about 10 nT. Magnetic field compensation is an effective way to shield the magnetic field, and this paper demonstrates an in situ triaxial magnetic field compensation system for operating the SERF atomic magnetometer. The proposed hardware is based on optical pumping, which uses some part of the SERF atomic magnetometer itself, and the compensation method is implemented by analyzing the dynamics of the atomic spin. The experimental setup for this compensation system is described, and with this configuration, a residual magnetic field of strength less than 2 nT (±0.38 nT in the x axis, ±0.43 nT in the y axis, and ±1.62 nT in the z axis) has been achieved after compensation. The SERF atomic magnetometer was then used to verify that the residual triaxial magnetic fields were coincident with what were achieved by the compensation system.

Review of Scientific Instruments•Oct 1, 2012•74 citations

SERF态效应所需零磁场环境的实现技术研究进展

崔梦缘 Cui Mengyuan, 王学锋 Wang Xuefeng, 邓意成 Deng Yicheng +1 more

The spin-exchange relaxation-free (SERF) state effect has been used to develop high-performance atomic magnetometers and atomic gyroscopes. Under the conditions of high-atomic number density and a zero-magnetic-field environment, alkali metal atoms enter the SERF state because the frequency of their spin-exchange collisions is much greater than the Larmor precession frequency. This results in a major reduction or even elimination of the atomic spin-exchange relaxation, and the linewidth of the atomic magnetic resonance becomes narrower. Heating the alkali metal atom vapor cell and shielding or compensating magnetic fields are key technologies used to attain the SERF state. To achieve a zero-magnetic-field environment, two methods are typically adopted: passive shielding the geomagnetic field with high-permeability materials, or active compensation of the ambient magnetic field with three-axis coils. This study elucidates the physical mechanism underlying the SERF effect, provides an in-depth examination of current techniques for achieving a zero-magnetic-field environment, and offers a comparative analysis of three approaches, namely passive shielding, active compensation, and an approach combining both. Additionally, this study provides technological prospects for achieving zero-magnetic-field environments.

Laser & Optoelectronics Progress•Jan 1, 2025•0 citations

Magnetic Resonance Based Atomic Magnetometers

Antoine Weis, G. Bison, Z. D. Grujić

Smart sensors, measurement and instrumentation•Sep 21, 2016•39 citations
The spin-exchange-relaxation-free(SERF)atomic magnetometer with ultrahigh sensitive becomes the most effective measurement to analyze the component of the planet in space exploration.In order to improve the sensitivity of the SERF atomic magnetometer,we must avoid the influence on the SERF regime disturbed by environment magnetic field.In this paper we design an active compensation system based on in-situ magnetic measurement to compensate the magnetic disturbance.Firstly,we get the three-axis magnetic field information according to the measurement of pop-laser,then control the current of coil to generate a magnetic field which is opposite and equal to the disturbance,to keep the SERF regime.Finally,we validat the method with the atomic magnetometer experimental setup.The result shows that compared with the manual compensation method,the system can track the magnetic compensation point in real time,reduce the signal noise and compensate the magnetic disturbance successfully,validating the efficiency of the active compensation system and establishing the technique foundation of the production.
The spin-exchange-relaxation-free (SERF) atomic magnetometer is an ultra-high sensitivity magnetometer, but it must be operated in a magnetic field with strength less than about 10 nT. Magnetic field compensation is an effective way to shield the magnetic field, and this paper demonstrates an in situ triaxial magnetic field compensation system for operating the SERF atomic magnetometer. The proposed hardware is based on optical pumping, which uses some part of the SERF atomic magnetometer itself, and the compensation method is implemented by analyzing the dynamics of the atomic spin. The experimental setup for this compensation system is described, and with this configuration, a residual magnetic field of strength less than 2 nT (±0.38 nT in the x axis, ±0.43 nT in the y axis, and ±1.62 nT in the z axis) has been achieved after compensation. The SERF atomic magnetometer was then used to verify that the residual triaxial magnetic fields were coincident with what were achieved by the compensation system.
The spin-exchange relaxation-free (SERF) state effect has been used to develop high-performance atomic magnetometers and atomic gyroscopes. Under the conditions of high-atomic number density and a zero-magnetic-field environment, alkali metal atoms enter the SERF state because the frequency of their spin-exchange collisions is much greater than the Larmor precession frequency. This results in a major reduction or even elimination of the atomic spin-exchange relaxation, and the linewidth of the atomic magnetic resonance becomes narrower. Heating the alkali metal atom vapor cell and shielding or compensating magnetic fields are key technologies used to attain the SERF state. To achieve a zero-magnetic-field environment, two methods are typically adopted: passive shielding the geomagnetic field with high-permeability materials, or active compensation of the ambient magnetic field with three-axis coils. This study elucidates the physical mechanism underlying the SERF effect, provides an in-depth examination of current techniques for achieving a zero-magnetic-field environment, and offers a comparative analysis of three approaches, namely passive shielding, active compensation, and an approach combining both. Additionally, this study provides technological prospects for achieving zero-magnetic-field environments.