Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Foundations of Quantum Mechanics in the Light of New Technology

JAMIN-TYPE INTERFEROMETER FOR COLD NEUTRONS USING ETALON PLATES

Masaaki Kitaguchi, H. Funahashi, Masahiro Hino

Published Oct 1, 2002• 0 citations
Publisher

Abstract

The authors have proposed and tested a new type of multilayer cold-neutron interferometer based on a pair of etalons. The range of experimental application of conventional multilayer cold-neutron interferometer was limited due to the small spatial separation between the two coherent beams. Using etalons with an air gap of 20μm in spacing we have observed interference fringes with the contrast of (3.5 ± 0.7)%. The present results have demonstrated the feasibility of developing a cold neutron interferometer with a large path separation to carry out high precision measurements and new types of experiment.

DOI
10.1142/9789812776716_0055

Related papers

Development of Neutron Interferometer with Wide-Gapped “BSE”s for Precision Measurements

Yoshichika Seki, Masaaki Kitaguchi, H. Funahashi +4 more

We are developing large‐dimensional cold‐neutron interferometers with multilayer mirrors in order to investigate small interactions. In particular Jamin type interferometers composed of wide‐gapped “BSE”s, which divide the beam completely, can realize the precision measurement of topological Aharonov‐Casher effect. We have made a prototype with 200 μm gapped BSEs and confirmed the spatial separation of its two paths at monochromatic cold‐neutron beamline MINE2 on JRR‐3M reactor in JAEA.

AIP conference proceedings•Jan 1, 2007•0 citations

Cold Neutron Interferometry Using Multilayer Neutron Mirrors

Takeshi Kawai

The object of this report is to review the recent results and some perspectives on cold neutron interferometry using multilayer neutron mirrors developed in KUR.The purposes of our research are to develop new experimental techniques, new devices for controlling neutron spin states for opening up a new world of physics.A multilayer neutron polarizes working under a very low external magnetic field (low field magnetic mirror), Funahashi's interferometer, a cold neutron spin echo instrument, a multilayer neutron spill splitter and a cold neutron pulser were developed.The equiv- alency of the quantum precession induced by the effective gap layer of the multilayer neutron spin splitter and Larmor precession of neutron spin in a magnetic field is established.This idea allows us to develop a cold neutron phase-spin-echo interferometer (a neutron spin interferometer).The neutron spin interferometer and a cold neutron pulser enabled us to carry out the delayed choice experiment for answering the question "how the neutron wave propagates after being split by the semitransparent mirror (wave splitter)".• These matters are reviewed in this paper.•

Acta Physica Polonica A•Jul 1, 1999•0 citations

Neutron interferometers and apparatus

Helmut Rauch, Samuel A. Werner

Abstract Among the various areas of neutron optical research, neutron interferometry has provided some of the most challenging and spectacular developments. In most cases, separated coherent beams are used which are produced either by wavefront division (Young’s type) or by amplitude division (Mach− Zehnder type). These beams are subsequently coherently superposed after passing through regions of space where the neutron wavefunction is modified in phase and amplitude by various interactions: nuclear, magnetic, electromagnetic, gravitational, or by geometry and topology (as in Aharonov−Bohm-type experiments). Various types of neutron interferometers that have been tested are shown in Fig. 2.1. The first neutron interferometer was based upon wavefront division and biprism deflection, but it had several constraints for interferometric applications mainly due to the small beam separation (100 μm) (Maier-Leibnitz and Springer 1962). Nevertheless, this method gained further interest for diffraction experiments from macroscopic objects and for the detection of weak interaction effects where the long flight paths (10 m) enhance the sensitivity for the measurements of these effects (Gähler et al. 1980; Klein et al. 1981a). The perfect-crystal interferometer (Rauch et al. 1974) provides widely separated coherent beams and has become a standard method for advanced neutron optical investigations. The development of diffraction and phase grating interferometers extended the Mach-Zehnder interferometer method to very slow neutrons (loffe et al. 1985; Gruber et al. 1989). The superposition of spin-up and spin-down states in the longitudinal direction provides the basis for Larmor and Ramsey interferometry, where no lateral beam splitting is necessary. The well-known spin-echo systems (Mezei 1972) and zero-field spin-echo systems (Gähler and Golub 1987; Dubbers et al. 1989) are examples of such interferometers, which also play an important role in atom interferometry (Bord é 1989; Kasevich and Chu 1991; Riehle et al. 1991).

Oxford University Press eBooks•Aug 10, 2000•0 citations

Neutron Interference and Phase Observation

Masahiko Utsuro, Vladimir K. Ignatovich

This chapter contains sections titled: Neutron Interferometry with a Perfect Crystal Interferometer Experiments on Spin Behavior with a Perfect Crystal Interferometer Very Cold Neutron Interferometry with Grating Mirrors Time-Dependent Interferometry Neutron Interferometry with Single-Layer and Multilayer Mirrors Spin Interferometry Experiments with Magnetic Multilayer Mirrors

Wiley eBooks•Jan 13, 2010•0 citations

Quantum Beat Experiments Using a Cold Neutron Spin Interferometer

Toru Ebisawa, Dai Yamazaki, S. Tasaki +5 more

Easy quantum beat experiments have been developed using a new cold neutron spin interferometer, which brings us easy observation of quantum beat phenomena. The quantum beat is created by the coherent superposition of the spin eigenstates of cold neutron with different energy states, which are produced with two radio-frequency flippers. We observed quantum beat phenomena with a range of frequency from 4 kHz to 10 -5 Hz, which correspond to the energy differences from 1.66 ×10 -11 eV to 4.1 ×10 -20 eV. The principle and the arrangement of the quantum beat experiment are discussed, and typical measurement data are presented. Some applications of the quantum beat experiments are briefly proposed.

Journal of the Physical Society of Japan•May 15, 1998•9 citations

Far-field interference of a neutron white beam and the applications to noninvasive phase-contrast imaging

Dmitry A. Pushin, Dusan Sarenac, Daniel Seth Hussey +10 more

The phenomenon of interference plays a crucial role in the field of precision measurement science. Wave-particle duality has expanded the well-known interference effects of electromagnetic waves to massive particles. The majority of the wave-particle interference experiments require a near monochromatic beam which limits its applications due to the resulting low intensity. Here we demonstrate white beam interference in the far-field regime using a two-phase-grating neutron interferometer and its application to phase-contrast imaging. The functionality of this interferometer is based on the universal moir\'e effect that allows us to improve upon the standard Lau setup. Interference fringes were observed with monochromatic and polychromatic neutron beams for both continuous and pulsed beams. Far-field neutron interferometry allows for the full utilization of intense neutron sources for precision measurements of gradient fields. It also overcomes the alignment, stability, and fabrication challenges associated with the more familiar perfect-crystal neutron interferometer, as well as avoids the loss of intensity due to the absorption analyzer grating requirement in Talbot-Lau interferometer.

arXiv:1606.03445•Physical Review A•Apr 26, 2017•42 citations
The authors have proposed and tested a new type of multilayer cold-neutron interferometer based on a pair of etalons. The range of experimental application of conventional multilayer cold-neutron interferometer was limited due to the small spatial separation between the two coherent beams. Using etalons with an air gap of 20μm in spacing we have observed interference fringes with the contrast of (3.5 ± 0.7)%. The present results have demonstrated the feasibility of developing a cold neutron interferometer with a large path separation to carry out high precision measurements and new types of experiment.
We are developing large‐dimensional cold‐neutron interferometers with multilayer mirrors in order to investigate small interactions. In particular Jamin type interferometers composed of wide‐gapped “BSE”s, which divide the beam completely, can realize the precision measurement of topological Aharonov‐Casher effect. We have made a prototype with 200 μm gapped BSEs and confirmed the spatial separation of its two paths at monochromatic cold‐neutron beamline MINE2 on JRR‐3M reactor in JAEA.
The object of this report is to review the recent results and some perspectives on cold neutron interferometry using multilayer neutron mirrors developed in KUR.The purposes of our research are to develop new experimental techniques, new devices for controlling neutron spin states for opening up a new world of physics.A multilayer neutron polarizes working under a very low external magnetic field (low field magnetic mirror), Funahashi's interferometer, a cold neutron spin echo instrument, a multilayer neutron spill splitter and a cold neutron pulser were developed.The equiv- alency of the quantum precession induced by the effective gap layer of the multilayer neutron spin splitter and Larmor precession of neutron spin in a magnetic field is established.This idea allows us to develop a cold neutron phase-spin-echo interferometer (a neutron spin interferometer).The neutron spin interferometer and a cold neutron pulser enabled us to carry out the delayed choice experiment for answering the question "how the neutron wave propagates after being split by the semitransparent mirror (wave splitter)".• These matters are reviewed in this paper.•
Abstract Among the various areas of neutron optical research, neutron interferometry has provided some of the most challenging and spectacular developments. In most cases, separated coherent beams are used which are produced either by wavefront division (Young’s type) or by amplitude division (Mach− Zehnder type). These beams are subsequently coherently superposed after passing through regions of space where the neutron wavefunction is modified in phase and amplitude by various interactions: nuclear, magnetic, electromagnetic, gravitational, or by geometry and topology (as in Aharonov−Bohm-type experiments). Various types of neutron interferometers that have been tested are shown in Fig. 2.1. The first neutron interferometer was based upon wavefront division and biprism deflection, but it had several constraints for interferometric applications mainly due to the small beam separation (100 μm) (Maier-Leibnitz and Springer 1962). Nevertheless, this method gained further interest for diffraction experiments from macroscopic objects and for the detection of weak interaction effects where the long flight paths (10 m) enhance the sensitivity for the measurements of these effects (Gähler et al. 1980; Klein et al. 1981a). The perfect-crystal interferometer (Rauch et al. 1974) provides widely separated coherent beams and has become a standard method for advanced neutron optical investigations. The development of diffraction and phase grating interferometers extended the Mach-Zehnder interferometer method to very slow neutrons (loffe et al. 1985; Gruber et al. 1989). The superposition of spin-up and spin-down states in the longitudinal direction provides the basis for Larmor and Ramsey interferometry, where no lateral beam splitting is necessary. The well-known spin-echo systems (Mezei 1972) and zero-field spin-echo systems (Gähler and Golub 1987; Dubbers et al. 1989) are examples of such interferometers, which also play an important role in atom interferometry (Bord é 1989; Kasevich and Chu 1991; Riehle et al. 1991).
Easy quantum beat experiments have been developed using a new cold neutron spin interferometer, which brings us easy observation of quantum beat phenomena. The quantum beat is created by the coherent superposition of the spin eigenstates of cold neutron with different energy states, which are produced with two radio-frequency flippers. We observed quantum beat phenomena with a range of frequency from 4 kHz to 10 -5 Hz, which correspond to the energy differences from 1.66 ×10 -11 eV to 4.1 ×10 -20 eV. The principle and the arrangement of the quantum beat experiment are discussed, and typical measurement data are presented. Some applications of the quantum beat experiments are briefly proposed.
The phenomenon of interference plays a crucial role in the field of precision measurement science. Wave-particle duality has expanded the well-known interference effects of electromagnetic waves to massive particles. The majority of the wave-particle interference experiments require a near monochromatic beam which limits its applications due to the resulting low intensity. Here we demonstrate white beam interference in the far-field regime using a two-phase-grating neutron interferometer and its application to phase-contrast imaging. The functionality of this interferometer is based on the universal moir\'e effect that allows us to improve upon the standard Lau setup. Interference fringes were observed with monochromatic and polychromatic neutron beams for both continuous and pulsed beams. Far-field neutron interferometry allows for the full utilization of intense neutron sources for precision measurements of gradient fields. It also overcomes the alignment, stability, and fabrication challenges associated with the more familiar perfect-crystal neutron interferometer, as well as avoids the loss of intensity due to the absorption analyzer grating requirement in Talbot-Lau interferometer.