Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Frontiers in Optics

Progress Toward a Precision Measurement of the Atomic Recoil Frequency Using A Grating Echo Interferometer

Anantharaman Kumarakrishnan, B. Barrett, Adam C. Carew

Published Jan 1, 2012• 0 citations
Publisher

Abstract

We discuss progress toward a precise measurement of the atomic recoil frequency using a grating-echo atom interferometer and a non-magnetic apparatus that permits interferometer signal lifetimes approaching the transit time limit.
DOI
10.1364/ls.2012.ltu1i.1

Related papers

Progress toward a precision measurement of the atomic recoil frequency using an echo-type atom interferometer

B. Barrett, Scott Beattie, Adam C. Carew +4 more

We discuss progress towards a precision measurement of the atomic recoil frequency in 85Rb using an echo-type atom interferometer. We report a single measurement precision of ~ 300 ppb on a timescale of ~ 50 ms.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Sep 10, 2010•0 citations

Measuring the atomic recoil frequency using a modified grating-echo atom interferometer

B. Barrett, A. Carew, Scott Beattie +1 more

We describe progress toward a precise measurement of the recoil energy of an atom measured using a modified grating-echo atom interferometer (AI) that involves three standing-wave (sw) pulses. With this technique, an additional sw pulse is used to shift the phase of excited momentum states, which produces a modulation in the contrast of the interference pattern. The signal exhibits narrow fringes that revive periodically at twice the two-photon recoil frequency, $2{\ensuremath{\omega}}_{q}$, as a function of the onset time of the pulse. Experiments are performed using samples of laser-cooled rubidium atoms with temperatures $\ensuremath{\lesssim}$5 $\ensuremath{\mu}$K in a nonmagnetic apparatus. We demonstrate a measurement of ${\ensuremath{\omega}}_{q}$ with a statistical uncertainty of 37 parts per ${10}^{9}$ (ppb) on a time scale of $\ensuremath{\sim}$45 ms in 14 h. Further statistical improvements are anticipated by extending this time scale and narrowing the signal fringe width. However, the total systematic uncertainty is estimated to be $\ensuremath{\sim}$6 parts per ${10}^{6}$ (ppm). We describe methods of reducing these systematic errors.

arXiv:1209.5624•Physical Review A•Mar 25, 2013•21 citations

Technique for measuring atomic recoil frequency using coherence functions

Scott Beattie, B. Barrett, I. Y. Chan +3 more

We have developed a technique for measuring the atomic recoil frequency using a single-state echo-type atom interferometer that manipulates laser-cooled atoms in the ground state. The interferometer relies on momentum-state interference due to two standing-wave pulses that produce density gratings. The interference is modified by applying a third standing-wave pulse during the interferometer pulse sequence. As a result, the grating contrast exhibits periodic revivals at the atomic recoil frequency ${\ensuremath{\omega}}_{r}$ as a function of the time at which the third pulse is applied, allowing ${\ensuremath{\omega}}_{r}$ to be measured easily and precisely. The contrast is accurately described by a coherence function, which is the Fourier transform of the momentum distribution, produced by the third pulse and by the theory of echo formation. If the third pulse is a traveling wave, loss of grating contrast is observed, an effect also described by a coherence function. The decay of the grating contrast as a function of continuous-wave light intensity is used to infer the cross section for photon absorption.

Physical Review A•Feb 13, 2009•12 citations

Progress towards a precision measurement of atomic recoil frequency using an echo interferometer

B. Barrett, Adam C. Carew, Scott Beattie +4 more

Bulletin of the American Physical Society•May 28, 2010•0 citations

A New Technique for Measuring Atomic Recoil Frequency Using Coherence Functions

Scott Beattie, B. Barrett, I. Y. Chan +3 more

We have developed a technique for measuring the atomic recoil frequency using a single-state echo-type atom interferometer that manipulates laser-cooled atoms in the ground state. The interferometer relies on momentum-state interference due to two standing-wave pulses that produce density gratings. The interference is modified by applying a third standing-wave pulse during the interferometer pulse sequence. As a result, the grating contrast exhibits periodic revivals at the atomic recoil frequency r as a function of the time at which the third pulse is applied, allowing r to be measured easily and precisely. The contrast is accurately described by a coherence function, which is the Fourier transform of the momentum distribution, produced by the third pulse and by the theory of echo formation. If the third pulse is a traveling wave, loss of grating contrast is observed, an effect also described by a coherence function. The decay of the grating contrast as a function of continuous-wave light intensity is used to infer the cross section for photon absorption.

Bulletin of the American Physical Society•May 22, 2009•0 citations

Techniques for measuring the atomic recoil frequency using a grating-echo atom interferometer

B. Barrett

•Jan 1, 2012•6 citations
We describe progress toward a precise measurement of the recoil energy of an atom measured using a modified grating-echo atom interferometer (AI) that involves three standing-wave (sw) pulses. With this technique, an additional sw pulse is used to shift the phase of excited momentum states, which produces a modulation in the contrast of the interference pattern. The signal exhibits narrow fringes that revive periodically at twice the two-photon recoil frequency, $2{\ensuremath{\omega}}_{q}$, as a function of the onset time of the pulse. Experiments are performed using samples of laser-cooled rubidium atoms with temperatures $\ensuremath{\lesssim}$5 $\ensuremath{\mu}$K in a nonmagnetic apparatus. We demonstrate a measurement of ${\ensuremath{\omega}}_{q}$ with a statistical uncertainty of 37 parts per 109{10}^{9}109 (ppb) on a time scale of $\ensuremath{\sim}$45 ms in 14 h. Further statistical improvements are anticipated by extending this time scale and narrowing the signal fringe width. However, the total systematic uncertainty is estimated to be $\ensuremath{\sim}$6 parts per 106{10}^{6}106 (ppm). We describe methods of reducing these systematic errors.
We have developed a technique for measuring the atomic recoil frequency using a single-state echo-type atom interferometer that manipulates laser-cooled atoms in the ground state. The interferometer relies on momentum-state interference due to two standing-wave pulses that produce density gratings. The interference is modified by applying a third standing-wave pulse during the interferometer pulse sequence. As a result, the grating contrast exhibits periodic revivals at the atomic recoil frequency ${\ensuremath{\omega}}_{r}$ as a function of the time at which the third pulse is applied, allowing ${\ensuremath{\omega}}_{r}$ to be measured easily and precisely. The contrast is accurately described by a coherence function, which is the Fourier transform of the momentum distribution, produced by the third pulse and by the theory of echo formation. If the third pulse is a traveling wave, loss of grating contrast is observed, an effect also described by a coherence function. The decay of the grating contrast as a function of continuous-wave light intensity is used to infer the cross section for photon absorption.
We have developed a technique for measuring the atomic recoil frequency using a single-state echo-type atom interferometer that manipulates laser-cooled atoms in the ground state. The interferometer relies on momentum-state interference due to two standing-wave pulses that produce density gratings. The interference is modified by applying a third standing-wave pulse during the interferometer pulse sequence. As a result, the grating contrast exhibits periodic revivals at the atomic recoil frequency r as a function of the time at which the third pulse is applied, allowing r to be measured easily and precisely. The contrast is accurately described by a coherence function, which is the Fourier transform of the momentum distribution, produced by the third pulse and by the theory of echo formation. If the third pulse is a traveling wave, loss of grating contrast is observed, an effect also described by a coherence function. The decay of the grating contrast as a function of continuous-wave light intensity is used to infer the cross section for photon absorption.