Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1209.5624 · Physical Review A

Measuring the atomic recoil frequency using a modified grating-echo atom interferometer

B. Barrett, A. Carew, Scott Beattie, Anantharaman Kumarakrishnan

Published Mar 25, 2013• 21 citations
arXivHTMLPDF

Abstract

We describe progress toward a precise measurement of the recoil energy of an atom measured using a modified grating-echo atom interferometer (AI) that involves three standing-wave (sw) pulses. With this technique, an additional sw pulse is used to shift the phase of excited momentum states, which produces a modulation in the contrast of the interference pattern. The signal exhibits narrow fringes that revive periodically at twice the two-photon recoil frequency, $2{\ensuremath{\omega}}_{q}$, as a function of the onset time of the pulse. Experiments are performed using samples of laser-cooled rubidium atoms with temperatures $\ensuremath{\lesssim}$5 $\ensuremath{\mu}$K in a nonmagnetic apparatus. We demonstrate a measurement of ${\ensuremath{\omega}}_{q}$ with a statistical uncertainty of 37 parts per ${10}^{9}$ (ppb) on a time scale of $\ensuremath{\sim}$45 ms in 14 h. Further statistical improvements are anticipated by extending this time scale and narrowing the signal fringe width. However, the total systematic uncertainty is estimated to be $\ensuremath{\sim}$6 parts per ${10}^{6}$ (ppm). We describe methods of reducing these systematic errors.

DOI
10.1103/physreva.87.033626

Related papers

Technique for measuring atomic recoil frequency using coherence functions

Scott Beattie, B. Barrett, I. Y. Chan +3 more

We have developed a technique for measuring the atomic recoil frequency using a single-state echo-type atom interferometer that manipulates laser-cooled atoms in the ground state. The interferometer relies on momentum-state interference due to two standing-wave pulses that produce density gratings. The interference is modified by applying a third standing-wave pulse during the interferometer pulse sequence. As a result, the grating contrast exhibits periodic revivals at the atomic recoil frequency ${\ensuremath{\omega}}_{r}$ as a function of the time at which the third pulse is applied, allowing ${\ensuremath{\omega}}_{r}$ to be measured easily and precisely. The contrast is accurately described by a coherence function, which is the Fourier transform of the momentum distribution, produced by the third pulse and by the theory of echo formation. If the third pulse is a traveling wave, loss of grating contrast is observed, an effect also described by a coherence function. The decay of the grating contrast as a function of continuous-wave light intensity is used to infer the cross section for photon absorption.

Physical Review A•Feb 13, 2009•12 citations

A New Technique for Measuring Atomic Recoil Frequency Using Coherence Functions

Scott Beattie, B. Barrett, I. Y. Chan +3 more

We have developed a technique for measuring the atomic recoil frequency using a single-state echo-type atom interferometer that manipulates laser-cooled atoms in the ground state. The interferometer relies on momentum-state interference due to two standing-wave pulses that produce density gratings. The interference is modified by applying a third standing-wave pulse during the interferometer pulse sequence. As a result, the grating contrast exhibits periodic revivals at the atomic recoil frequency r as a function of the time at which the third pulse is applied, allowing r to be measured easily and precisely. The contrast is accurately described by a coherence function, which is the Fourier transform of the momentum distribution, produced by the third pulse and by the theory of echo formation. If the third pulse is a traveling wave, loss of grating contrast is observed, an effect also described by a coherence function. The decay of the grating contrast as a function of continuous-wave light intensity is used to infer the cross section for photon absorption.

Bulletin of the American Physical Society•May 22, 2009•0 citations

Demonstration of improved sensitivity of echo interferometers to gravitational acceleration

Carson Mok, B. Barrett, Adam C. Carew +3 more

We have developed two configurations of an echo interferometer that rely on standing-wave excitation of a laser-cooled sample of rubidium atoms. Both configurations can be used to measure acceleration $a$ along the axis of excitation. For a two-pulse configuration, the signal from the interferometer is modulated at the recoil frequency and exhibits a sinusoidal frequency chirp as a function of pulse spacing. In comparison, for a three-pulse stimulated-echo configuration, the signal is observed without recoil modulation and exhibits a modulation at a single frequency as a function of pulse spacing. The three-pulse configuration is less sensitive to effects of vibrations and magnetic field curvature, leading to a longer experimental time scale. For both configurations of the atom interferometer (AI), we show that a measurement of acceleration with a statistical precision of 0.5% can be realized by analyzing the shape of the echo envelope that has a temporal duration of a few microseconds. Using the two-pulse AI, we obtain measurements of acceleration that are statistically precise to 6 parts per million (ppm) on a 25 ms time scale. In comparison, using the three-pulse AI, we obtain measurements of acceleration that are statistically precise to 0.4 ppm on a time scale of 50 ms. A further statistical enhancement is achieved by analyzing the data across the echo envelope so that the statistical error is reduced to 75 parts per billion (ppb). The inhomogeneous field of a magnetized vacuum chamber limited the experimental time scale and resulted in prominent systematic effects. Extended time scales and improved signal-to-noise ratio observed in recent echo experiments using a nonmagnetic vacuum chamber suggest that echo techniques are suitable for a high-precision measurement of gravitational acceleration $g$. We discuss methods for reducing systematic effects and improving the signal-to-noise ratio. Simulations of both AI configurations with a time scale of 300 ms suggest that an optimized experiment with improved vibration isolation and atoms selected in the ${m}_{F}=0$ state can result in measurements of $g$ statistically precise to 0.3 ppb for the two-pulse AI and 0.6 ppb for the three-pulse AI.

arXiv:1307.1902•Physical Review A•Aug 20, 2013•16 citations

Atom-interferometric studies of light scattering

Scott Beattie, B. Barrett, I. Y. Chan +3 more

We have used an echo-type atom interferometer that manipulates laser-cooled atoms in a single ground state to investigate the effect of light scattering from pulsed and continuous-wave light. The interferometer uses two off-resonant standing-wave pulses applied at times $t=0$ and $t=T$ to diffract and recombine momentum states separated by $2\ensuremath{\hbar}k$ at $t=2T$. Matter wave interference is associated with the formation of a density grating with period $\ensuremath{\lambda}/2$ in the vicinity of this echo time. The grating contrast is measured by recording the intensity of coherently backscattered light. The interferometer is perturbed by an additional pulse applied at $t=2T\ensuremath{-}\ensuremath{\delta}T$ or by continuous-wave background light. If the additional pulse is a standing wave, the momentum states interfering at $t=2T$ are displaced and the grating contrast can be completely recovered due to constructive interference. In this case, the contrast shows a periodic modulation at the atomic recoil frequency as a function of $\ensuremath{\delta}T$. In a recent work, it was shown that the atomic recoil frequency can be measured easily and precisely when using coherence functions to model the signal shape. This paper provides an alternative description of the signal shape through an analytical calculation of echo formation in the presence of an additional standing-wave pulse. Using this treatment, it is possible to model the effects of spontaneous emission and spatial profile of the laser beam on the signal shape. Additionally, the theory predicts scaling laws as a function of the pulse area and the number of additional standing-wave pulses. These scaling laws are investigated experimentally and can be exploited to improve precision measurements of the atomic recoil frequency. We also show that coherence functions can be used to make a direct measurement of the populations of momentum states associated with the ground state under conditions where the Doppler-broadened velocity distribution of the sample is much larger than the recoil velocity. These measurements are consistent with Monte Carlo wave-function simulations. If the additional pulse is a traveling wave, we find that the grating contrast measured as a function of $\ensuremath{\delta}T$ can be modeled by a quasiperiodic coherence function as in previous experiments that utilized atomic beams. In this work, we investigate the dependence of the photon scattering rate on the intensity and detuning of the traveling wave. We also study the effects of perturbing the interferometer with continuous-wave light and find that the dependence of the photon scattering rate on the intensity and detuning of the perturbing field is consistent with expectations.

Physical Review A•Jul 29, 2009•10 citations

Prospects for Precise Measurements with Echo Atom Interferometry

B. Barrett, Adam C. Carew, Hermina C. Beica +3 more

Echo atom interferometers have emerged as interesting alternatives to Raman interferometers for the realization of precise measurements of the gravitational acceleration g and the determination of the atomic fine structure through measurements of the atomic recoil frequency ω q . Here we review the development of different configurations of echo interferometers that are best suited to achieve these goals. We describe experiments that utilize near-resonant excitation of laser-cooled rubidium atoms by a sequence of standing wave pulses to measure ω q with a statistical uncertainty of 37 parts per billion (ppb) on a time scale of ∼50 ms and g with a statistical precision of 75 ppb. Related coherent transient techniques that have achieved the most statistically precise measurements of atomic g-factor ratios are also outlined. We discuss the reduction of prominent systematic effects in these experiments using off-resonant excitation by low-cost, high-power lasers.

arXiv:1606.06831•Atoms•Jun 27, 2016•23 citations

Improving the sensitivity grating-echo atom interferometers for measurements of gravity

Gehrig Carlse, Jaskaran Randhawa, Alexander Pouliot +4 more

Precision measurements of gravitational acceleration g have far reaching applications in navigation and sensing as well as for tests of general relativity. Grating-echo atom interferometers (AIs) utilize simple setups and distinctive excitation schemes that involve a single excitation laser, and do not require velocity selection. They have demonstrated measurements of gravity precise to 75 parts per billion (ppb) by dropping laser-cooled atomic samples through ~ 1 cm. Here we describe progress toward realizing a cold atom gravimeter using an echo AI designed for drop heights of ~30 cm. The experimental technique involves illuminating the falling sample of laser-cooled rubidium atoms with two standing wave (sw) pulses separated by time t = T. The sw pulses are composed of two traveling-wave components, each having a wave vector of magnitude k = 2π/λ. Momentum state interference produces one-dimensional density gratings with a period λ/2 immediately after each excitation pulse. These gratings dephase due to the velocity distribution of the sample along the sw axis. The AI uses an echo technique to cancel the effect of velocity dephasing and observe a rephased density grating in the vicinity of the echo time τ = 2Τ. The grating contrast and phase are measured by coherently backscattering a traveling wave readout pulse from the sample. The grating phase, measured with respect to a vibrationally stabilized inertial reference frame, scales as 2kgΤ2. A drawback of echo AIs is the signal-to-noise ratio, which is limited by the contrast of the grating and systematic effects due the refractive index of the sample. Here, we review improvements to the experimental design and investigate methods of improving the signal-to-noise ratio by optimizing the atom-field coupling. We describe progress toward realizing our goals of increasing the grating contrast and the backscattered signal. The improved contrast is expected to allow the experiment to be carried out at a lower density to reduce corrections due to the refractive index. We discuss a variety of excitation schemes for achieving a target precision of a few ppb.

Optical and Quantum Sensing and Precision Metrology II•Mar 13, 2024•0 citations
We describe progress toward a precise measurement of the recoil energy of an atom measured using a modified grating-echo atom interferometer (AI) that involves three standing-wave (sw) pulses. With this technique, an additional sw pulse is used to shift the phase of excited momentum states, which produces a modulation in the contrast of the interference pattern. The signal exhibits narrow fringes that revive periodically at twice the two-photon recoil frequency, 2\ensuremathωq2{\ensuremath{\omega}}_{q}2\ensuremathωq​, as a function of the onset time of the pulse. Experiments are performed using samples of laser-cooled rubidium atoms with temperatures \ensuremath≲\ensuremath{\lesssim}\ensuremath≲5 \ensuremathμ\ensuremath{\mu}\ensuremathμK in a nonmagnetic apparatus. We demonstrate a measurement of \ensuremathωq{\ensuremath{\omega}}_{q}\ensuremathωq​ with a statistical uncertainty of 37 parts per 109{10}^{9}109 (ppb) on a time scale of \ensuremath∼\ensuremath{\sim}\ensuremath∼45 ms in 14 h. Further statistical improvements are anticipated by extending this time scale and narrowing the signal fringe width. However, the total systematic uncertainty is estimated to be \ensuremath∼\ensuremath{\sim}\ensuremath∼6 parts per 106{10}^{6}106 (ppm). We describe methods of reducing these systematic errors.
We have developed a technique for measuring the atomic recoil frequency using a single-state echo-type atom interferometer that manipulates laser-cooled atoms in the ground state. The interferometer relies on momentum-state interference due to two standing-wave pulses that produce density gratings. The interference is modified by applying a third standing-wave pulse during the interferometer pulse sequence. As a result, the grating contrast exhibits periodic revivals at the atomic recoil frequency ${\ensuremath{\omega}}_{r}$ as a function of the time at which the third pulse is applied, allowing ${\ensuremath{\omega}}_{r}$ to be measured easily and precisely. The contrast is accurately described by a coherence function, which is the Fourier transform of the momentum distribution, produced by the third pulse and by the theory of echo formation. If the third pulse is a traveling wave, loss of grating contrast is observed, an effect also described by a coherence function. The decay of the grating contrast as a function of continuous-wave light intensity is used to infer the cross section for photon absorption.
We have developed a technique for measuring the atomic recoil frequency using a single-state echo-type atom interferometer that manipulates laser-cooled atoms in the ground state. The interferometer relies on momentum-state interference due to two standing-wave pulses that produce density gratings. The interference is modified by applying a third standing-wave pulse during the interferometer pulse sequence. As a result, the grating contrast exhibits periodic revivals at the atomic recoil frequency r as a function of the time at which the third pulse is applied, allowing r to be measured easily and precisely. The contrast is accurately described by a coherence function, which is the Fourier transform of the momentum distribution, produced by the third pulse and by the theory of echo formation. If the third pulse is a traveling wave, loss of grating contrast is observed, an effect also described by a coherence function. The decay of the grating contrast as a function of continuous-wave light intensity is used to infer the cross section for photon absorption.
We have developed two configurations of an echo interferometer that rely on standing-wave excitation of a laser-cooled sample of rubidium atoms. Both configurations can be used to measure acceleration aaa along the axis of excitation. For a two-pulse configuration, the signal from the interferometer is modulated at the recoil frequency and exhibits a sinusoidal frequency chirp as a function of pulse spacing. In comparison, for a three-pulse stimulated-echo configuration, the signal is observed without recoil modulation and exhibits a modulation at a single frequency as a function of pulse spacing. The three-pulse configuration is less sensitive to effects of vibrations and magnetic field curvature, leading to a longer experimental time scale. For both configurations of the atom interferometer (AI), we show that a measurement of acceleration with a statistical precision of 0.5% can be realized by analyzing the shape of the echo envelope that has a temporal duration of a few microseconds. Using the two-pulse AI, we obtain measurements of acceleration that are statistically precise to 6 parts per million (ppm) on a 25 ms time scale. In comparison, using the three-pulse AI, we obtain measurements of acceleration that are statistically precise to 0.4 ppm on a time scale of 50 ms. A further statistical enhancement is achieved by analyzing the data across the echo envelope so that the statistical error is reduced to 75 parts per billion (ppb). The inhomogeneous field of a magnetized vacuum chamber limited the experimental time scale and resulted in prominent systematic effects. Extended time scales and improved signal-to-noise ratio observed in recent echo experiments using a nonmagnetic vacuum chamber suggest that echo techniques are suitable for a high-precision measurement of gravitational acceleration ggg. We discuss methods for reducing systematic effects and improving the signal-to-noise ratio. Simulations of both AI configurations with a time scale of 300 ms suggest that an optimized experiment with improved vibration isolation and atoms selected in the mF=0{m}_{F}=0mF​=0 state can result in measurements of ggg statistically precise to 0.3 ppb for the two-pulse AI and 0.6 ppb for the three-pulse AI.
We have used an echo-type atom interferometer that manipulates laser-cooled atoms in a single ground state to investigate the effect of light scattering from pulsed and continuous-wave light. The interferometer uses two off-resonant standing-wave pulses applied at times t=0t=0t=0 and t=Tt=Tt=T to diffract and recombine momentum states separated by $2\ensuremath{\hbar}k$ at t=2Tt=2Tt=2T. Matter wave interference is associated with the formation of a density grating with period $\ensuremath{\lambda}/2$ in the vicinity of this echo time. The grating contrast is measured by recording the intensity of coherently backscattered light. The interferometer is perturbed by an additional pulse applied at $t=2T\ensuremath{-}\ensuremath{\delta}T$ or by continuous-wave background light. If the additional pulse is a standing wave, the momentum states interfering at t=2Tt=2Tt=2T are displaced and the grating contrast can be completely recovered due to constructive interference. In this case, the contrast shows a periodic modulation at the atomic recoil frequency as a function of $\ensuremath{\delta}T$. In a recent work, it was shown that the atomic recoil frequency can be measured easily and precisely when using coherence functions to model the signal shape. This paper provides an alternative description of the signal shape through an analytical calculation of echo formation in the presence of an additional standing-wave pulse. Using this treatment, it is possible to model the effects of spontaneous emission and spatial profile of the laser beam on the signal shape. Additionally, the theory predicts scaling laws as a function of the pulse area and the number of additional standing-wave pulses. These scaling laws are investigated experimentally and can be exploited to improve precision measurements of the atomic recoil frequency. We also show that coherence functions can be used to make a direct measurement of the populations of momentum states associated with the ground state under conditions where the Doppler-broadened velocity distribution of the sample is much larger than the recoil velocity. These measurements are consistent with Monte Carlo wave-function simulations. If the additional pulse is a traveling wave, we find that the grating contrast measured as a function of $\ensuremath{\delta}T$ can be modeled by a quasiperiodic coherence function as in previous experiments that utilized atomic beams. In this work, we investigate the dependence of the photon scattering rate on the intensity and detuning of the traveling wave. We also study the effects of perturbing the interferometer with continuous-wave light and find that the dependence of the photon scattering rate on the intensity and detuning of the perturbing field is consistent with expectations.
Echo atom interferometers have emerged as interesting alternatives to Raman interferometers for the realization of precise measurements of the gravitational acceleration g and the determination of the atomic fine structure through measurements of the atomic recoil frequency ω q . Here we review the development of different configurations of echo interferometers that are best suited to achieve these goals. We describe experiments that utilize near-resonant excitation of laser-cooled rubidium atoms by a sequence of standing wave pulses to measure ω q with a statistical uncertainty of 37 parts per billion (ppb) on a time scale of ∼50 ms and g with a statistical precision of 75 ppb. Related coherent transient techniques that have achieved the most statistically precise measurements of atomic g-factor ratios are also outlined. We discuss the reduction of prominent systematic effects in these experiments using off-resonant excitation by low-cost, high-power lasers.
Precision measurements of gravitational acceleration g have far reaching applications in navigation and sensing as well as for tests of general relativity. Grating-echo atom interferometers (AIs) utilize simple setups and distinctive excitation schemes that involve a single excitation laser, and do not require velocity selection. They have demonstrated measurements of gravity precise to 75 parts per billion (ppb) by dropping laser-cooled atomic samples through ~ 1 cm. Here we describe progress toward realizing a cold atom gravimeter using an echo AI designed for drop heights of ~30 cm. The experimental technique involves illuminating the falling sample of laser-cooled rubidium atoms with two standing wave (sw) pulses separated by time t = T. The sw pulses are composed of two traveling-wave components, each having a wave vector of magnitude k = 2π/λ. Momentum state interference produces one-dimensional density gratings with a period λ/2 immediately after each excitation pulse. These gratings dephase due to the velocity distribution of the sample along the sw axis. The AI uses an echo technique to cancel the effect of velocity dephasing and observe a rephased density grating in the vicinity of the echo time τ = 2Τ. The grating contrast and phase are measured by coherently backscattering a traveling wave readout pulse from the sample. The grating phase, measured with respect to a vibrationally stabilized inertial reference frame, scales as 2kgΤ2. A drawback of echo AIs is the signal-to-noise ratio, which is limited by the contrast of the grating and systematic effects due the refractive index of the sample. Here, we review improvements to the experimental design and investigate methods of improving the signal-to-noise ratio by optimizing the atom-field coupling. We describe progress toward realizing our goals of increasing the grating contrast and the backscattered signal. The improved contrast is expected to allow the experiment to be carried out at a lower density to reduce corrections due to the refractive index. We discuss a variety of excitation schemes for achieving a target precision of a few ppb.