Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Acta Optica Sinica

Bias Detector Used for Fluorescence Spectrum of Strontium Intercombination Transition

丛东亮 Cong Dongliang, 王叶兵 Wang Yebing, 许朋 Xu Peng, Hong Chang

Published Jan 1, 2012• 1 citation
Publisher
DOI
10.3788/aos201232.0704001

Related papers

Study on Fluorescence Spectrum of Strontium Intercombination Transition and Its Characteristics

胡福云 HU Fu-yun, 雷贵 LEI Gui, 韩建新 HAN Jian-xin +2 more

Acta Sinica Quantum Optica•Jan 1, 2019•0 citations

Realization of Narrow Linewidth Fluorescence Spectrum of Strontium Intercombination Transition and Analysis of Its Line Broadening Factors

刘辉 Liu Hui, 任洁 Ren Jie, 田晓 Tian Xiao +1 more

Acta Optica Sinica•Jan 1, 2013•0 citations

Observation of Atomic Coherence in Intercombination Transition Line of Strontium Atom

王叶兵 Wang Yebing, 丛东亮 Cong Dongliang, 许朋 Xu Peng +2 more

Acta Optica Sinica•Jan 1, 2013•0 citations

Near-recoil-limited temperatures obtained by laser trapping on the narrow 1S0-3P1 intercombination transition of neutral strontium

Kurt R. Vogel, T. Dinneen, Alan Gallagher +1 more

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Apr 1, 1999•1 citation

Experimental investigation of spectrum of strontium intercombination transition

Wang Ye-Bing, Chen Jie, Tian Xiao +2 more

We observe the fluorescence and the saturated fluorescence spectra of (5s2)1S0(5s5p)3P1 intercombination transition of thermal strontium atomic beam. Experimental investigation of 88Sr(5s2)1S0(5s5p)3P1 intercombination transition is performed on the different experimental conditions. Our study indicates that experimental parameters affect spectra largely, including temperature, intensity of laser and scanning frequency of laser. Intensity of spectrum is reciprocal of scanning frequency of laser due to long lifetime of (5s5p)3P1 state of Sr atom. Owing to Doppler broadening, transit broadening and other experimental factors, the linewidth of (5s2)1S0(5s5p)3P1 fluorescence spectrum is far more than its natural linewidth and proportional scanning frequency of laser.

Acta Physica Sinica•Jan 1, 2012•3 citations

Shelving spectroscopy of the strontium intercombination line

Isam Manai, Molineri, A, Fréjaville, C +8 more

We present a spectroscopy scheme for the 7-kHz-wide 689-nm intercombination line of strontium. We rely on shelving detection, where electrons are first excited to a metastable state by the spectroscopy laser before their state is probed using the broad transition at 461 nm. As in the similar setting of calcium beam clocks, this enhances dramatically the signal strength as compared to direct saturated fluorescence or absorption spectroscopy of the narrow line. We implement shelving spectroscopy both in directed atomic beams and hot vapor cells with isotropic atomic velocities. We measure a fractional frequency instability $\sim 2 \times 10^{-12}$ at 1 s limited by technical noise - about one order of magnitude above shot noise limitations for our experimental parameters. Our work illustrates the robustness and flexibility of a scheme that can be very easily implemented in the reference cells or ovens of most existing strontium experiments, and may find applications for low-complexity clocks.

•Oct 25, 2019•3 citations
We observe the fluorescence and the saturated fluorescence spectra of (5s2)1S0(5s5p)3P1 intercombination transition of thermal strontium atomic beam. Experimental investigation of 88Sr(5s2)1S0(5s5p)3P1 intercombination transition is performed on the different experimental conditions. Our study indicates that experimental parameters affect spectra largely, including temperature, intensity of laser and scanning frequency of laser. Intensity of spectrum is reciprocal of scanning frequency of laser due to long lifetime of (5s5p)3P1 state of Sr atom. Owing to Doppler broadening, transit broadening and other experimental factors, the linewidth of (5s2)1S0(5s5p)3P1 fluorescence spectrum is far more than its natural linewidth and proportional scanning frequency of laser.
We present a spectroscopy scheme for the 7-kHz-wide 689-nm intercombination line of strontium. We rely on shelving detection, where electrons are first excited to a metastable state by the spectroscopy laser before their state is probed using the broad transition at 461 nm. As in the similar setting of calcium beam clocks, this enhances dramatically the signal strength as compared to direct saturated fluorescence or absorption spectroscopy of the narrow line. We implement shelving spectroscopy both in directed atomic beams and hot vapor cells with isotropic atomic velocities. We measure a fractional frequency instability ∼2×10−12\sim 2 \times 10^{-12}∼2×10−12 at 1 s limited by technical noise - about one order of magnitude above shot noise limitations for our experimental parameters. Our work illustrates the robustness and flexibility of a scheme that can be very easily implemented in the reference cells or ovens of most existing strontium experiments, and may find applications for low-complexity clocks.