The Rochester Conferences on Coherence and Quantum Optics and the Quantum Information and Measurement meeting

Sensitive estimation of angular displacements using weak measurements

Omar S. Magaña‐Loaiza, Mohammad Mirhosseini, Brandon Rodenburg, Robert W. Boyd

Published Jan 1, 2013• 0 citations
Publisher

Abstract

We demonstrate an experimental method that allows for sensitive measurements of angular position of light using weak value amplification. This offers an alternative to previously established methods that use nonclassical light for angular displacement estimation.
DOI
10.1364/cqo.2013.m6.45

Related papers

Amplification of Angular Rotations using Weak Measurements

Omar S. Magaña‐Loaiza, Mohammad Mirhosseini, Brandon Rodenburg +1 more

We experimentally demonstrate the first weak-value amplification of the azimuthal degree of freedom. We estimate rotations using shifts in angular position and orbital angular momentum, via spin-orbit coupling and an applied geometric phase.

Frontiers in Optics•Jan 1, 2014•16 citations

Amplification of Angular Rotations Using Weak Measurements

Omar S. Magaña‐Loaiza, Mohammad Mirhosseini, Brandon Rodenburg +1 more

We present a weak measurement protocol that permits a sensitive estimation of angular rotations based on the concept of weak-value amplification. The shift in the state of a pointer, in both angular position and the conjugate orbital angular momentum bases, is used to estimate angular rotations. This is done by an amplification of both the real and imaginary parts of the weak-value of a polarization operator that has been coupled to the pointer, which is a spatial mode, via a spin-orbit coupling. Our experiment demonstrates the first realization of weak-value amplification in the azimuthal degree of freedom. We have achieved effective amplification factors as large as 100, providing a sensitivity that is on par with more complicated methods that employ quantum states of light or extremely large values of orbital angular momentum.

arXiv:1312.2981•Physical Review Letters•May 21, 2014•223 citations

Observing angular deviations in light beam reflection via weak measurements

Gaurav Jayaswal, Giampaolo Mistura, Michele Merano

We report the first observation of the angular Goos-Hänchen shift for a Gaussian light beam via weak value amplification. Weak measurements faithfully amplify the effect at any angle of incidence, even at Brewster.

Frontiers in Optics•Jan 1, 2014•6 citations

Development of an “Interferometric Quasi-Autocollimator”

Matthew D. Turner, Charles A. Hagedorn, Stephan Schlamminger +1 more

We have developed a device that uses weak-value amplification to measure angular deflections of a target mirror while remaining insensitive to all translations of the target. We present demonstrated sensitivities and discuss practical implementation.

Frontiers in Optics•Jan 1, 2011•0 citations

Experimental Ultra-small Longitudinal Phase Estimation via Weak Measurement Amplification

Mengjun Hu, Xiao‐Min Hu, Bi‐Heng Liu +4 more

Weak value amplification has been applied to various small physical quantities estimation, however there still lacks a practical feasible protocol to amplify ultra-small longitudinal phase, which is of importance in high precision measurement. Very recently, a different amplification protocol within the framework of weak measurements is proposed to solve this problem, which is capable of measuring any ultra-small longitudinal phase signal that conventional interferometry tries to do. Here we experimentally demonstrate this weak measurements amplification protocol of ultra-small longitudinal phase and realize one order of magnitude amplification in the same technical condition, which verifies the validity of the protocol and show higher precision and sensitivity than conventional interferometry. Our results significantly broaden the area of applications of weak measurements and may play an important role in high precision measurements.

•Jan 1, 2018•2 citations

Amplification of Optical Pulse Delays using Weak Measurements

Mohammad Mirhosseini, Omar S. Magaña‐Loaiza, Mehul Malik +1 more

A novel scheme for super-sensitive measurement of optical pulse delays is proposed based on the concept of weak-value amplification. We discuss an experimental implementation of this technique utilizing a Mach-Zehnder interferometer.

The Rochester Conferences on Coherence and Quantum Optics and the Quantum Information and Measurement meeting•Jan 1, 2013•0 citations
We present a weak measurement protocol that permits a sensitive estimation of angular rotations based on the concept of weak-value amplification. The shift in the state of a pointer, in both angular position and the conjugate orbital angular momentum bases, is used to estimate angular rotations. This is done by an amplification of both the real and imaginary parts of the weak-value of a polarization operator that has been coupled to the pointer, which is a spatial mode, via a spin-orbit coupling. Our experiment demonstrates the first realization of weak-value amplification in the azimuthal degree of freedom. We have achieved effective amplification factors as large as 100, providing a sensitivity that is on par with more complicated methods that employ quantum states of light or extremely large values of orbital angular momentum.
Weak value amplification has been applied to various small physical quantities estimation, however there still lacks a practical feasible protocol to amplify ultra-small longitudinal phase, which is of importance in high precision measurement. Very recently, a different amplification protocol within the framework of weak measurements is proposed to solve this problem, which is capable of measuring any ultra-small longitudinal phase signal that conventional interferometry tries to do. Here we experimentally demonstrate this weak measurements amplification protocol of ultra-small longitudinal phase and realize one order of magnitude amplification in the same technical condition, which verifies the validity of the protocol and show higher precision and sensitivity than conventional interferometry. Our results significantly broaden the area of applications of weak measurements and may play an important role in high precision measurements.