Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Acta Sinica Quantum Optica

The Experimental Investigation of 795 nm Correlation Photons Caused by Spontaneous Parametric Down-Conversion

郝红玉 HAO Hong-yu, 田龙 Tian Long, 原浩翔 YUAN Hao-xiang, 李淑静 LI Shu-jing, 王海 WANG Hai

Published Jan 1, 2014• 2 citations
Publisher
DOI
10.3788/asqo20142003.0177

Related papers

Research on the time-correlation characterisrtic of correlated photon circles generated by the type-I spontaneous parametric down-conversion

Liu Yan, Jian-Jun Li, Gao Dongyang +5 more

The optical radiometric calibration method based on correlated photons generated by spontaneous parametric down-conversion (SPDC) is a promising method,because it is based on the basic physical phenomena and does not need radiometric traceability.At the present,the SPDC calibration technology is applicable for the photon-counting detector with a highest calibration accuracy of 0.18%.More and more researchers are making effort to improve its calibration accuracy and expand its applicable targets to analog detectors.Correlated photon circles have the high photon rate characteristic.The photon rates of signal and idle light can be improved significantly by using correlated photon circles in calibration.It has very important significance to study the time-correlation characteristic of correlated photon circles. In this paper,the spatial distribution of emission angle of the broadband (450-1000 nm) correlated photons generated by type-I spontaneous parametric down-conversion is presented through the theoretical calculations.The ZEMAX optical software is used to design the optical system which can receive the broadband correlated photon circles and remove the pump laser which is the main source of stray light.The 355 nm wavelength laser is used to pump -barium borate (BBO) crystal to generate the broadband correlated photon circles.A low-light-level CMOS camera is used to adjust and align the opt-mechanical system.Finally,the 430 nm-860 nm correlated photon circles are received by the optical system and detected by the low-light-level CMOS camera.An experimental measurement system is established to measure the time-correlation characteristics of 685 nm and 736.89 nm correlated photon circles.Using 1.0 mW continuous-wave laser to pump BBO crystal,a coincidence peak is observed evidently.The results show that the correlated photon circles generated by type-I SPDC have the characteristics of time-correlation and high photon rates.It can be conductive to improving optical radiometric calibration accuracy based on correlated photons and promoting the development and application in analog detector calibration.

Acta Physica Sinica•Jan 1, 2016•1 citation

Spatial correlation of photon pairs produced in spontaneous parametric down-conversion

Lorenzo M. Procopio, Óscar Rosas-Ortiz, Víctor Velázquez +4 more

AIP conference proceedings•Jan 1, 2010•7 citations

Transverse coherence of photon pairs generated in spontaneous parametric down-conversion

Martin Hamar, Jan Peřina, Ondřej Haderka +1 more

Coherence properties of the down-converted beams generated in spontaneous parametric down-conversion are investigated in detail using an iCCD camera. Experimental results are compared with those from a theoretical model developed for pulsed pumping with a Gaussian transverse profile. The results allow us to tailor the shape of correlation area of the signal and idler photons using pump-field and crystal parameters. As an example, splitting of a correlation area caused by a two-peak pump-field spectrum is experimentally studied.

arXiv:1003.1249•Physical Review A•Apr 21, 2010•45 citations

Quantum correlations of light produced in spontaneous parametric frequency down-conversion process

Ievgen I. Arkhipov

•Jan 1, 2017•0 citations

Investigation of Two-Photon Correlation Effects in Parametric Down-Conversion

Chung Ki Hong

•Jan 1, 1988•0 citations

Characterizing a 474 nm Laser as a Source for Spontaneous Parametric Down Conversion

J. A. Balmer, L.C. Howard

There is an important class of experiments that characterize the properties of quantum mechanical systems using correlated photons, and a typical source for correlated photons is the process of Spontaneous Parametric Down Conversion (SPDC). SPDC is a quantum mechanical process in which a single “pump” photon is converted into two photons that have half the frequency and double the wavelength of the original photon. This process takes place inside a crystal with particular optical properties that allow for SPDC, and we used a uniaxial Beta Barium Borate crystal. A single photon counting module (SPCM) was used as a detector for the photons. Our goal was to characterize a 474 nanometer (nm) Diode Pumped Solid State (DPSS) laser as a possible source for SPDC correlated photons. Measurements of the DPSS laser radiation showed that it emitted photons with a wavelength of both 474 nm and 948 nm, which was expected. The SPDC photons produced by our apparatus would also have a wavelength of 948 nm, so we tested whether the down converted photons could be detected without the 948 nm signal from the DPSS laser overwhelming the SPCM. Software for determining the parameters of SPDC in a given system is available from the National Institute of Standards and Technology, and we used it to determine where we could expect to see SPDC photons. Initial measurements suggest that the system can produce SPDC photons, and we will continue to characterize the apparatus.

•Jan 1, 2013•0 citations
The optical radiometric calibration method based on correlated photons generated by spontaneous parametric down-conversion (SPDC) is a promising method,because it is based on the basic physical phenomena and does not need radiometric traceability.At the present,the SPDC calibration technology is applicable for the photon-counting detector with a highest calibration accuracy of 0.18%.More and more researchers are making effort to improve its calibration accuracy and expand its applicable targets to analog detectors.Correlated photon circles have the high photon rate characteristic.The photon rates of signal and idle light can be improved significantly by using correlated photon circles in calibration.It has very important significance to study the time-correlation characteristic of correlated photon circles. In this paper,the spatial distribution of emission angle of the broadband (450-1000 nm) correlated photons generated by type-I spontaneous parametric down-conversion is presented through the theoretical calculations.The ZEMAX optical software is used to design the optical system which can receive the broadband correlated photon circles and remove the pump laser which is the main source of stray light.The 355 nm wavelength laser is used to pump -barium borate (BBO) crystal to generate the broadband correlated photon circles.A low-light-level CMOS camera is used to adjust and align the opt-mechanical system.Finally,the 430 nm-860 nm correlated photon circles are received by the optical system and detected by the low-light-level CMOS camera.An experimental measurement system is established to measure the time-correlation characteristics of 685 nm and 736.89 nm correlated photon circles.Using 1.0 mW continuous-wave laser to pump BBO crystal,a coincidence peak is observed evidently.The results show that the correlated photon circles generated by type-I SPDC have the characteristics of time-correlation and high photon rates.It can be conductive to improving optical radiometric calibration accuracy based on correlated photons and promoting the development and application in analog detector calibration.
Coherence properties of the down-converted beams generated in spontaneous parametric down-conversion are investigated in detail using an iCCD camera. Experimental results are compared with those from a theoretical model developed for pulsed pumping with a Gaussian transverse profile. The results allow us to tailor the shape of correlation area of the signal and idler photons using pump-field and crystal parameters. As an example, splitting of a correlation area caused by a two-peak pump-field spectrum is experimentally studied.
There is an important class of experiments that characterize the properties of quantum mechanical systems using correlated photons, and a typical source for correlated photons is the process of Spontaneous Parametric Down Conversion (SPDC). SPDC is a quantum mechanical process in which a single “pump” photon is converted into two photons that have half the frequency and double the wavelength of the original photon. This process takes place inside a crystal with particular optical properties that allow for SPDC, and we used a uniaxial Beta Barium Borate crystal. A single photon counting module (SPCM) was used as a detector for the photons. Our goal was to characterize a 474 nanometer (nm) Diode Pumped Solid State (DPSS) laser as a possible source for SPDC correlated photons. Measurements of the DPSS laser radiation showed that it emitted photons with a wavelength of both 474 nm and 948 nm, which was expected. The SPDC photons produced by our apparatus would also have a wavelength of 948 nm, so we tested whether the down converted photons could be detected without the 948 nm signal from the DPSS laser overwhelming the SPCM. Software for determining the parameters of SPDC in a given system is available from the National Institute of Standards and Technology, and we used it to determine where we could expect to see SPDC photons. Initial measurements suggest that the system can produce SPDC photons, and we will continue to characterize the apparatus.