The optical radiometric calibration method based on correlated photons generated by spontaneous parametric down-conversion (SPDC) is a promising method,because it is based on the basic physical phenomena and does not need radiometric traceability.At the present,the SPDC calibration technology is applicable for the photon-counting detector with a highest calibration accuracy of 0.18%.More and more researchers are making effort to improve its calibration accuracy and expand its applicable targets to analog detectors.Correlated photon circles have the high photon rate characteristic.The photon rates of signal and idle light can be improved significantly by using correlated photon circles in calibration.It has very important significance to study the time-correlation characteristic of correlated photon circles. In this paper,the spatial distribution of emission angle of the broadband (450-1000 nm) correlated photons generated by type-I spontaneous parametric down-conversion is presented through the theoretical calculations.The ZEMAX optical software is used to design the optical system which can receive the broadband correlated photon circles and remove the pump laser which is the main source of stray light.The 355 nm wavelength laser is used to pump -barium borate (BBO) crystal to generate the broadband correlated photon circles.A low-light-level CMOS camera is used to adjust and align the opt-mechanical system.Finally,the 430 nm-860 nm correlated photon circles are received by the optical system and detected by the low-light-level CMOS camera.An experimental measurement system is established to measure the time-correlation characteristics of 685 nm and 736.89 nm correlated photon circles.Using 1.0 mW continuous-wave laser to pump BBO crystal,a coincidence peak is observed evidently.The results show that the correlated photon circles generated by type-I SPDC have the characteristics of time-correlation and high photon rates.It can be conductive to improving optical radiometric calibration accuracy based on correlated photons and promoting the development and application in analog detector calibration.
The optical radiometric calibration method based on correlated photons generated by spontaneous parametric down-conversion (SPDC) is a promising method,because it is based on the basic physical phenomena and does not need radiometric traceability.At the present,the SPDC calibration technology is applicable for the photon-counting detector with a highest calibration accuracy of 0.18%.More and more researchers are making effort to improve its calibration accuracy and expand its applicable targets to analog detectors.Correlated photon circles have the high photon rate characteristic.The photon rates of signal and idle light can be improved significantly by using correlated photon circles in calibration.It has very important significance to study the time-correlation characteristic of correlated photon circles. In this paper,the spatial distribution of emission angle of the broadband (450-1000 nm) correlated photons generated by type-I spontaneous parametric down-conversion is presented through the theoretical calculations.The ZEMAX optical software is used to design the optical system which can receive the broadband correlated photon circles and remove the pump laser which is the main source of stray light.The 355 nm wavelength laser is used to pump -barium borate (BBO) crystal to generate the broadband correlated photon circles.A low-light-level CMOS camera is used to adjust and align the opt-mechanical system.Finally,the 430 nm-860 nm correlated photon circles are received by the optical system and detected by the low-light-level CMOS camera.An experimental measurement system is established to measure the time-correlation characteristics of 685 nm and 736.89 nm correlated photon circles.Using 1.0 mW continuous-wave laser to pump BBO crystal,a coincidence peak is observed evidently.The results show that the correlated photon circles generated by type-I SPDC have the characteristics of time-correlation and high photon rates.It can be conductive to improving optical radiometric calibration accuracy based on correlated photons and promoting the development and application in analog detector calibration.
The correlated photon technique makes it possible to achieve a radiation calibration processing without chain transferring. The study of the spectral radiation character and time correlation of the photon is of great significance for broad-band radiometric calibration. To absolutely calibrate quantum efficiency of photoelectric detector, it is necessary to extend calibration band from single band to more bands. According to the phase-matching condition of the spontaneous parametric down-conversion, non-collinear angle formula of correlated photon in the crystal is derived. The distribution of the photon spectrum is simulated. Meanwhile, the phase-matching angle of the crystal is optimized. The photon generated by the spontaneous parameters down-conversion has a broad spectral distribution and the correlated photon wavelength is corresponding to its emission angle. Based on the result of the simulation, the experimental measurement system of the spectral distribution and time-correlation of the correlated photon is established. The spectral distribution, the time-correlation and the polarization properties of the four pair photon were measured by using this system. The experimental results show that, (1) the spectral distribution of the measurements is 633~808 nm, where the maximum spectral distribution measurement bias is 1.51 mm. The experiment result is highly consistent with theoretical ones; (2) the correlation time of four pairs correlated photon is measured, during which “three coincidence-peaks” is observed and the minimum correlation time was 0.32 ns; (3) single photon count rate along with coincidence count rate of correlated photon vary with the polarization direction of the pump as sine function. The experimental result is shown that the correlated photon pairs are ranging from the visible to near infrared band distribution, and that the spectrum has time-correlation and polarization characteristic. The research result is firstly reported at home and abroad, and the results are promising for the application of the photoelectric detector in the multi-band radiometric calibration.
A new calibration method of detectors can be realized by using correlated photons generated in spontaneous parametric down-conversion (SPDC) effect of nonlinear crystal.An absolute calibration system of detector quantum efficiency is performed.And its principle and experimental setup are introduced.A continuouswave (CW) ultraviolet (351 nm), diode-pumped, frequency-doubled, and solid-state laser is used to pump BBO crystal.The quantum efficiencies of the photomultiplier at 633, 702, and 789 nm are measured respectively.The coincidence peaks are observed using coincidence circuit.Some measurement factors including the filter bandwidth of trigger channel, the detector position alignment and polarization of the pump light are analyzed.The uncertainties of this calibration method are also analyzed, and the relative uncertainties of total calibration are less than 5.8%.The accuracy of this method could be improved in the future.
There is an important class of experiments that characterize the properties of quantum mechanical systems using correlated photons, and a typical source for correlated photons is the process of Spontaneous Parametric Down Conversion (SPDC). SPDC is a quantum mechanical process in which a single “pump” photon is converted into two photons that have half the frequency and double the wavelength of the original photon. This process takes place inside a crystal with particular optical properties that allow for SPDC, and we used a uniaxial Beta Barium Borate crystal. A single photon counting module (SPCM) was used as a detector for the photons. Our goal was to characterize a 474 nanometer (nm) Diode Pumped Solid State (DPSS) laser as a possible source for SPDC correlated photons. Measurements of the DPSS laser radiation showed that it emitted photons with a wavelength of both 474 nm and 948 nm, which was expected. The SPDC photons produced by our apparatus would also have a wavelength of 948 nm, so we tested whether the down converted photons could be detected without the 948 nm signal from the DPSS laser overwhelming the SPCM. Software for determining the parameters of SPDC in a given system is available from the National Institute of Standards and Technology, and we used it to determine where we could expect to see SPDC photons. Initial measurements suggest that the system can produce SPDC photons, and we will continue to characterize the apparatus.
The high-precision self-calibration radiation reference source is currently the research focus of satellite remote sensing calibration. In order to meet the requirements of quantitative applications such as climate monitoring, low-light radiation metering and single photon source radiance measurement, in view of the application requirements and technical requirements of visible to near infrared low-light radiometer, a compact three-channel low-light radiance meter based on correlated photon self-calibration is designed. This design method can improve the measurement accuracy of low light irradiance by using objective physical effect instead of physical standard, reducing the cumulative error caused by standard transfer chain. The absolute calibration of the detector responsivity can be achieved by the spontaneous parameter down-conversion effect, and the absolute radiation observation can be achieved without relying on the external reference. Based on this study, combined with the special application requirements of radiance meter, a numerical model of spectral rate and geometric transmission characteristics of wide spectrum correlated photons is established, and two basic operating modes of self-calibration and radiation observation are determined. The interaction between 355 nm pump source and nonlinear medium generates three-wave mixing, and the correlated photons are generated by class I non-collinear spontaneous parametric downconversion, the combined effect of monochromatic pump photon flow and quantum vacuum noise on non-centrosymmetric nonlinear crystal makes each incident photon spontaneously split into two photons with lower energy with a certain probability, called signal photons and idle photons respectively, they have a wide sptrum distribution from pump wave frequency to lattice resonance frequency. Correlated photon source has the technical characteristics of time and space correlation, natural wide spectrum and absolute reproducibility, so it has high absolute accuracy. Integrated design of self-calibration and radiation observation can monitor and correct changes in response characteristics in real time, maintain long-term stability of response characteristics, and improve traceability and accuracy of observation data. This design method solve the key technologies such as preparation and value transfer of correlated photon sources, suppression of pump stray light, high precision and high efficiency coupling of correlated photons, UV radiation resistance of space single-photon detectors, packaging reinforcement technology of space single-photon detectors,self-calibration and integrated design of radiation observation. The spectral measurement range of the low-light radiance meter is from 460 nm to 1 550 nm, the measurement range of radiance is 1×10-9~1×10-6 W/(cm2·sr·nm). In the design, the integration, miniaturization and modularization of the whole system are considered, and the eight spectral bands are integrated into a three-channel structure, solving the preparation of wide spectrum dependent photon source, optical multiplexing of calibration optical path, radiation measurement, high precision coincidence measurement and full optical path calibration of radiance meter, and achieving high precision radiation observation from visible to near infrared and periodic self-calibration research targets. In the self-calibration mode, the multiplex optical path module periodically introduces the spontaneous parametric down-conversion correlated photons, and the photon counting and coincidence detection module are used to calibrate the absolute quantum efficiency of the three channels. In the radiation observation mode, the multiplex optical path module introduces the low-light level target radiation and obtains the absolute spectral radiance of the observation target in the band of 460~1 550 nm at the same time. The calibration coefficient obtained by the self-calibration mode is used to correct the observation results. The effects of link error limited by radiation reference value transfer, optical decay of optical path and electronic decay of optical path on the measurement accuracy of microradiance are fundamentally solved. The visible near-infrared band adopts free space coupling mode and the short-wave infrared band adopts multi-mode fiber coupling mode. Through design optimization analysis, the focusing spots of the first and second channels meet the 300 μm pixel requirement of Si single photon detector, and the focusing spot of the third channel meets the 62.5 μm core diameter and 0.22 numerical aperture requirement of multi-mode fiber, all of them can be received by the detector photosensitive surface, meeting the design objectives. The method based on correlated photon calibration does not need to trace the high-precision primary standard in the laboratory and the lengthy standard transfer chain. By using the correlated photon generated in the process of parametric down-conversion, the calibration source of time, space and polarization can be obtained, and the high-precision observation of the low-light spectrum radiance from visible to near infrared band can be realized. The solution to the scientific problem of low-light observation instrument in space platform measurement can obtain higher calibration accuracy, and play an important role in climate monitoring, low-light radiation metrology, single-photon source radiance measurement and so on.
The prerequisite for achieving precise mid-infrared (3 000~5 000 nm) radiation measurement is calibration. In recent years, the technology using correlated photons generated by Spontaneous Parametric Down-Conversion (SPDC) for calibration has attracted widespread attention as an absolute calibration method requiring no external standard transfer. This approach, based on an objective physical effect, enables self-calibration. However, limited by the absence of infrared single-photon detectors, research surveys indicate its primary applications have been confined to calibration within the visible-near-infrared spectral range. Up-conversion technology, as a novel infrared single-photon detection method, enables the detection of correlated photon signals in the mid-infrared band.This paper first introduces the principle and mathematical expression for determining channel detection efficiency through correlated photon calibration. Subsequently, an experimental optical path combining parametric down-conversion and up-conversion technologies was constructed, with detailed descriptions of the setup procedures, particularly emphasizing the principles of correlated photon focusing and beam combining. The experiment initially utilized a 775 nm laser to pump a Periodically Poled Lithium Niobate (PPLN) crystal, generating 1 005 nm/3 390 nm correlated photon pairs via SPDC. The 1 005 nm signal photons were routed through the trigger path, while the 3 390 nm idler photons were directed to the measurement path. To address the challenge of lacking mid-infrared single-photon detectors, the 3 390 nm idler photons in the measurement path were up-converted to 810 nm through sum-frequency generation with 1 064 nm pump light in another PPLN crystal. Silicon-based near-infrared single-photon detectors of the same model were used to detect the 1 005 nm and 810 nm photons separately. The outputs from both near-infrared single-photon detectors were connected to a Time-to-Digital Converter (TDC) for time-correlated coincidence measurements. Practical experimental issues including dead time, afterpulses, accidental coincidences, and differences in non-common optical paths were analyzed. A 3 390 nm laser was employed to measure the transmittance of non-common optical paths at 3 390 nm. Based on the modified expression for calculating channel efficiency in correlated photon calibration, the detection efficiency of the measurement path for 3 390 nm was determined by removing the influence of non-common optical path efficiency using the measured coincidence counts and trigger photon counts.The study further investigated the limitations on the area and solid angle of mid-infrared radiation in the measurement path. By comparing the acceptance areas and solid angles for mid-infrared radiation between the up-conversion section and the fiber-coupled collection section, it was concluded that the fiber-coupled collection component imposed the primary constraints on the solid angle and area of mid-infrared radiation. Combining the calibrated detection efficiency of the measurement path, an expression for calculating mid-infrared radiance from up-converted photon counts was derived.The calibrated system was used to measure the radiance of a cavity-type blackbody at 3 390 nm under temperatures of 125 ℃, 150 ℃, 175 ℃, and 200 ℃. Experimental results were compared with theoretical radiance values calculated using Planck's formula, revealing a maximum discrepancy of 4.3%. This demonstrates the potential application prospects of combining up-conversion and down-conversion technologies for absolute radiance measurement beyond 3 000 nm. Finally, possible causes for the observed discrepancies were analyzed, including potential uncalibrated blackbody emissivity and slight laser power fluctuations during the experiment. Future optimizations for the system were proposed, such as incorporating laser power stabilization modules, to further enhance measurement accuracy.
There are two general methods for radiometric calibration of detectors. One is based on radiometric sources and the other is based on detectors. Because two methods need to establish primary standard of high precision and transfer chain of standard, the precision of standard will be reduced by extension of the chain. An absolute calibration of quantum efficiency of detectors can be realized by using correlated photons generated in spontaneous parametric down-conversion (SPDC) effect of nonlinear crystal. Generation mechanism of SPDC is interpreted with theories of quantum mechanics and classical theories. The theory of calibration based correlated photons are demonstrated. The project for proof of principle of absolute calibration of quantum efficiency of radiometric detectors is given in this paper. Comparing with traditional methods, the advantages of it are pointed out. A scheme using to calibrate quantum efficiency of infrared detectors is described here. The measurement of spatial and spectral response of detectors is mentioned too.