Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Research in Optical Sciences

Cavity enhanced quantum limited magnetometry

Georgios Vasilakis, Heng Shen, Kasper Jensen, D. Salart, Anne M. Fabricant, M. V. Balabas, Eugene Simon Polzik

Published Jan 1, 2014• 1 citation
Publisher

Abstract

We present a quantum limited, high-spatial-resolution, radio-frequency magnetometer by optical readout of polarized Cesium spins at room temperature. The atomic vapours are contained in a microcell and placed inside a cavity for optical depth enhancement.
DOI
10.1364/qim.2014.qtu3b.6

Related papers

Cavity enhanced atomic magnetometry

Herbert Crepaz, Li Yuan Ley, Rainer Dumke

Atom sensing based on Faraday rotation is an indispensable method for precision measurements, universally suitable for both hot and cold atomic systems. Here we demonstrate an all-optical magnetometer where the optical cell for Faraday rotation spectroscopy is augmented with a low finesse cavity. Unlike in previous experiments, where specifically designed multipass cells had been employed, our scheme allows to use conventional, spherical vapour cells. Spherical shaped cells have the advantage that they can be effectively coated inside with a spin relaxation suppressing layer providing long spin coherence times without addition of a buffer gas. Cavity enhancement shows in an increase in optical polarization rotation and sensitivity compared to single-pass configurations.

arXiv:1510.00919•Scientific Reports•Oct 20, 2015•27 citations

Room temperature femtotesla radio-frequency atomic magnetometer

Witold Chałupczak, R. M. Godun, Szymon Pustelny +1 more

A radio-frequency tunable atomic magnetometer with a sensitivity of about 1 fT/Hz1/2 in a range of 10–500 kHz is demonstrated. The magnetometer is operated in the orientation configuration in which atoms are pumped to the stretched atomic state by a scheme based on indirect optical pumping using only one unmodulated, low-power laser. The magnetometer operates with cesium atoms, which have sufficient vapor pressure near room temperature to enable high magnetometric sensitivities. The technique enables a compact and robust module to be constructed that could become an in-the-field device.

Applied Physics Letters•Jun 11, 2012•87 citations

Ultracold Atomic Magnetometry: Towards Quantum-Limited Sensing

Sula, Sindi

This thesis presents advancements in radio-frequency atomic magnetometry utilising cold atoms as sensors. While cold atom magnetometers demonstrate lower absolute sensitivity compared to conventional vapour cell systems due to reduced atom numbers, they offer exceptional spatial resolution at the micrometre scale. The experimental apparatus features a cold atom production system capable of reaching quantum degeneracy through a refined cooling sequence that involves optical molasses, magnetic trapping and evaporation, and optical evaporative cooling in the dipole trap, culminating in a 87Rb Bose-Einstein condensate. This work details the development and characterisation of magnetometer set-ups with progressively enhanced performance. The first magnetometer utilised atoms in the optical molasses phase as a sensor, achieving an AC sensitivity of 330 pT/√Hz with approximately 108 atoms at 20 μK. Comprehensive magnetometry optimisation methods were developed to enhance sensitivity. Following laboratory interruptions due to the COVID-19 pandemic, system rebuilding incorporated significant upgrades, including a new probe laser and gradient compensation systems. The improved magnetometer prototype achieved a substantially enhanced sensitivity of 0.72±0.33 pT/√Hz, approaching the fundamental sensitivity limit of the system. Using atoms in the magnetic trap as a sensor, a sensitivity of 1.85 pT/√Hz was demonstrated. The system was verified to be photon-shot noise limited. Investigations into a double-pass probe configuration showed that, while the measured sensitivity was similar to that of the single-pass (4.3 pT/√Hz compared to 3.1 pT/√Hz at a probe power of 6.4 μW measured at the detector), the rotation angle increased by a factor of 2.2, with significantly reduced noise levels. These findings suggest that multi-pass strategies hold promise for enhanced performance in future implementations. In addition, the first signal detection from a BEC magnetometer, achieving 4.5 nT/√Hz with only 95,000 atoms at 35 nK was demonstrated.

•Oct 28, 2025•0 citations

Quantum Noise Limited and Entanglement-Assisted Magnetometry

Kasper Jensen, Wojciech Wasilewski, Hanna Krauter +3 more

We demonstrate a radio frequency atomic magnetometer with sub-femtoTesla/ Hz sensitivity, mainly limited by projection noise of atoms. Furthermore, we demonstrate that Einstein-Podolsky-Rosen entanglement of atoms enhances the sensitivity to broadband magnetic fields.

Conference on Lasers and Electro-Optics•Jan 1, 2010•18 citations

Quantum Applications of an Atomic Ensemble Inside a Laser Cavity

R. Shuker, Andrei Ben-Amar Baranga, David Levron +2 more

Many quantum device signals are proportional to the number of the participating atoms that take part in the detection devices. Among these are optical magnetometers, atomic clocks, quantum communications and atom interferometers. One way to enhance the signal-to-noise ratio is to introduce atom entanglement that increases the signal in a super-radiant-like effect. A coherent em field inside a laser cavity is suggested to achieve atoms’ correlation/entanglement. This may also play an important role in the basic quantum arena of many-body physics. An initial novel experiment to test the realization of atoms’ correlation is described here. A Cs optical magnetometer is used as a tool to test the operation of a cell-in-cavity laser and its characteristics. A vapor cell is inserted into an elongated external cavity of the pump laser in Littrow configuration. Higher atom polarization and reduced laser linewidth are obtained leading to better magnetometer sensitivity and signal-to-noise ratio. The Larmor frequency changes of the Free Induction Decay of optically pumped Cs atomic polarization in the ambient earth magnetic field at room temperature is measured. Temporal changes in the magnetic field of less than 10 pT/√Hz are measured. The first-order dependence of the magnetic field on temperature and temperature gradients is eliminated, important in many practical applications. Single and gradiometric magnetometer configurations are presented.

Photonics•Jan 2, 2024•0 citations

High-sensitivity magnetometry at room temperature with post-processed optical readout of single NV-centres

Antonio A. Gentile, Raffaele Santagati, Sebastian Knauer +11 more

Optical readout from nanofabricated single NV centres is enhanced via Bayesian inference techniques, to demonstrate efficient magnetometry at room temperature conditions. We achieve experimentally Heisenberg-limited sensitivities O(100 nT s1/2), thus competing with state-of-art cryogenic set-ups.

Conference on Lasers and Electro-Optics•Jan 1, 2019•0 citations
Atom sensing based on Faraday rotation is an indispensable method for precision measurements, universally suitable for both hot and cold atomic systems. Here we demonstrate an all-optical magnetometer where the optical cell for Faraday rotation spectroscopy is augmented with a low finesse cavity. Unlike in previous experiments, where specifically designed multipass cells had been employed, our scheme allows to use conventional, spherical vapour cells. Spherical shaped cells have the advantage that they can be effectively coated inside with a spin relaxation suppressing layer providing long spin coherence times without addition of a buffer gas. Cavity enhancement shows in an increase in optical polarization rotation and sensitivity compared to single-pass configurations.
A radio-frequency tunable atomic magnetometer with a sensitivity of about 1 fT/Hz1/2 in a range of 10–500 kHz is demonstrated. The magnetometer is operated in the orientation configuration in which atoms are pumped to the stretched atomic state by a scheme based on indirect optical pumping using only one unmodulated, low-power laser. The magnetometer operates with cesium atoms, which have sufficient vapor pressure near room temperature to enable high magnetometric sensitivities. The technique enables a compact and robust module to be constructed that could become an in-the-field device.
This thesis presents advancements in radio-frequency atomic magnetometry utilising cold atoms as sensors. While cold atom magnetometers demonstrate lower absolute sensitivity compared to conventional vapour cell systems due to reduced atom numbers, they offer exceptional spatial resolution at the micrometre scale. The experimental apparatus features a cold atom production system capable of reaching quantum degeneracy through a refined cooling sequence that involves optical molasses, magnetic trapping and evaporation, and optical evaporative cooling in the dipole trap, culminating in a 87Rb Bose-Einstein condensate. This work details the development and characterisation of magnetometer set-ups with progressively enhanced performance. The first magnetometer utilised atoms in the optical molasses phase as a sensor, achieving an AC sensitivity of 330 pT/√Hz with approximately 108 atoms at 20 μK. Comprehensive magnetometry optimisation methods were developed to enhance sensitivity. Following laboratory interruptions due to the COVID-19 pandemic, system rebuilding incorporated significant upgrades, including a new probe laser and gradient compensation systems. The improved magnetometer prototype achieved a substantially enhanced sensitivity of 0.72±0.33 pT/√Hz, approaching the fundamental sensitivity limit of the system. Using atoms in the magnetic trap as a sensor, a sensitivity of 1.85 pT/√Hz was demonstrated. The system was verified to be photon-shot noise limited. Investigations into a double-pass probe configuration showed that, while the measured sensitivity was similar to that of the single-pass (4.3 pT/√Hz compared to 3.1 pT/√Hz at a probe power of 6.4 μW measured at the detector), the rotation angle increased by a factor of 2.2, with significantly reduced noise levels. These findings suggest that multi-pass strategies hold promise for enhanced performance in future implementations. In addition, the first signal detection from a BEC magnetometer, achieving 4.5 nT/√Hz with only 95,000 atoms at 35 nK was demonstrated.
Many quantum device signals are proportional to the number of the participating atoms that take part in the detection devices. Among these are optical magnetometers, atomic clocks, quantum communications and atom interferometers. One way to enhance the signal-to-noise ratio is to introduce atom entanglement that increases the signal in a super-radiant-like effect. A coherent em field inside a laser cavity is suggested to achieve atoms’ correlation/entanglement. This may also play an important role in the basic quantum arena of many-body physics. An initial novel experiment to test the realization of atoms’ correlation is described here. A Cs optical magnetometer is used as a tool to test the operation of a cell-in-cavity laser and its characteristics. A vapor cell is inserted into an elongated external cavity of the pump laser in Littrow configuration. Higher atom polarization and reduced laser linewidth are obtained leading to better magnetometer sensitivity and signal-to-noise ratio. The Larmor frequency changes of the Free Induction Decay of optically pumped Cs atomic polarization in the ambient earth magnetic field at room temperature is measured. Temporal changes in the magnetic field of less than 10 pT/√Hz are measured. The first-order dependence of the magnetic field on temperature and temperature gradients is eliminated, important in many practical applications. Single and gradiometric magnetometer configurations are presented.