Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Foundations of Quantum Mechanics in the Light of New Technology

DEVELOPMENT OF MACH-ZEHNDER INTERFEROMETER AND "COHERENT BEAM STEERING" TECHNIQUE FOR COLD NEUTRONS

K. Taketani, H. Funahashi, Yoshichika Seki, M. Hino, Masaaki Kitaguchi, Ryuji Maruyama, Y. Otake, H. M. Shimizu

Published Jun 1, 2006• 0 citations
Publisher

Abstract

We are developing multilayer interferometer of Mach-Zehnder type for cold neutrons. To fulfill severe requirements for aligning the four mirrors, we utilize six solid-etalon-plates and a high precision flat base plate. New devices making use of magnetic birefringence have been developed and demonstrated to be useful for fine adjustment of superposition between the two paths labeled with neutron spin.

DOI
10.1142/9789812773210_0060

Related papers

Cold Neutron Interferometry Using Multilayer Neutron Mirrors

Takeshi Kawai

The object of this report is to review the recent results and some perspectives on cold neutron interferometry using multilayer neutron mirrors developed in KUR.The purposes of our research are to develop new experimental techniques, new devices for controlling neutron spin states for opening up a new world of physics.A multilayer neutron polarizes working under a very low external magnetic field (low field magnetic mirror), Funahashi's interferometer, a cold neutron spin echo instrument, a multilayer neutron spill splitter and a cold neutron pulser were developed.The equiv- alency of the quantum precession induced by the effective gap layer of the multilayer neutron spin splitter and Larmor precession of neutron spin in a magnetic field is established.This idea allows us to develop a cold neutron phase-spin-echo interferometer (a neutron spin interferometer).The neutron spin interferometer and a cold neutron pulser enabled us to carry out the delayed choice experiment for answering the question "how the neutron wave propagates after being split by the semitransparent mirror (wave splitter)".• These matters are reviewed in this paper.•

Acta Physica Polonica A•Jul 1, 1999•0 citations

JAMIN-TYPE INTERFEROMETER FOR COLD NEUTRONS USING ETALON PLATES

Masaaki Kitaguchi, H. Funahashi, Masahiro Hino

The authors have proposed and tested a new type of multilayer cold-neutron interferometer based on a pair of etalons. The range of experimental application of conventional multilayer cold-neutron interferometer was limited due to the small spatial separation between the two coherent beams. Using etalons with an air gap of 20μm in spacing we have observed interference fringes with the contrast of (3.5 ± 0.7)%. The present results have demonstrated the feasibility of developing a cold neutron interferometer with a large path separation to carry out high precision measurements and new types of experiment.

Foundations of Quantum Mechanics in the Light of New Technology•Oct 1, 2002•0 citations

Neutron interferometers and apparatus

Helmut Rauch, Samuel A. Werner

Among the various areas of neutron optical research, neutron interferometry has provided some of the most challenging and spectacular developments. In most cases, separated coherent beams are used which are produced either by wavefront division (Young’s type) or by amplitude division (Mach− Zehnder type). These beams are subsequently coherently superposed after passing through regions of space where the neutron wavefunction is modified in phase and amplitude by various interactions: nuclear, magnetic, electromagnetic, gravitational, or by geometry and topology (as in Aharonov−Bohm-type experiments). Various types of neutron interferometers that have been tested are shown in Fig. 2.1. The first neutron interferometer was based upon wavefront division and biprism deflection, but it had several constraints for interferometric applications mainly due to the small beam separation (100 μm) (Maier-Leibnitz and Springer 1962). Nevertheless, this method gained further interest for diffraction experiments from macroscopic objects and for the detection of weak interaction effects where the long flight paths (10 m) enhance the sensitivity for the measurements of these effects (Gähler et al. 1980; Klein et al. 1981a). The perfect-crystal interferometer (Rauch et al. 1974) provides widely separated coherent beams and has become a standard method for advanced neutron optical investigations. The development of diffraction and phase grating interferometers extended the Mach-Zehnder interferometer method to very slow neutrons (loffe et al. 1985; Gruber et al. 1989). The superposition of spin-up and spin-down states in the longitudinal direction provides the basis for Larmor and Ramsey interferometry, where no lateral beam splitting is necessary. The well-known spin-echo systems (Mezei 1972) and zero-field spin-echo systems (Gähler and Golub 1987; Dubbers et al. 1989) are examples of such interferometers, which also play an important role in atom interferometry (Bord é 1989; Kasevich and Chu 1991; Riehle et al. 1991).

Oxford University Press eBooks•Aug 10, 2000•0 citations

Neutron Interference and Phase Observation

Masahiko Utsuro, Vladimir K. Ignatovich

This chapter contains sections titled: Neutron Interferometry with a Perfect Crystal Interferometer Experiments on Spin Behavior with a Perfect Crystal Interferometer Very Cold Neutron Interferometry with Grating Mirrors Time-Dependent Interferometry Neutron Interferometry with Single-Layer and Multilayer Mirrors Spin Interferometry Experiments with Magnetic Multilayer Mirrors

Wiley eBooks•Jan 13, 2010•0 citations

The three-grating Mach Zehnder optical interferometer: a tutorial approach using particle optics

Alain Miffre, R. Delhuille, B. Viaris de Lesegno +3 more

In this paper, we present a tutorial set-up based on an optical three-grating Mach–Zehnder interferometer. As this apparatus is very similar in its principle to the Mach–Zehnder interferometers used with matter waves (neutrons, atoms and molecules), it can be used to familiarize students with particle optics, and in our explanations, we use the complementary points of view of wave optics and particle optics. Finally, we have used this interferometer to measure the index of refraction of BK 7 glass for red light at 633 nm, with a technique equivalent to the one used to measure the index of refraction of solid matter for thermal neutrons. The dimensions of this interferometer and its cost make it very interesting for laboratory courses and the experiment described here can be reproduced by students.

European Journal of Physics•Oct 15, 2002•14 citations

Development of Neutron Interferometer with Wide-Gapped “BSE”s for Precision Measurements

Yoshichika Seki, Masaaki Kitaguchi, H. Funahashi +4 more

We are developing large‐dimensional cold‐neutron interferometers with multilayer mirrors in order to investigate small interactions. In particular Jamin type interferometers composed of wide‐gapped “BSE”s, which divide the beam completely, can realize the precision measurement of topological Aharonov‐Casher effect. We have made a prototype with 200 μm gapped BSEs and confirmed the spatial separation of its two paths at monochromatic cold‐neutron beamline MINE2 on JRR‐3M reactor in JAEA.

AIP conference proceedings•Jan 1, 2007•0 citations
We are developing multilayer interferometer of Mach-Zehnder type for cold neutrons. To fulfill severe requirements for aligning the four mirrors, we utilize six solid-etalon-plates and a high precision flat base plate. New devices making use of magnetic birefringence have been developed and demonstrated to be useful for fine adjustment of superposition between the two paths labeled with neutron spin.
The object of this report is to review the recent results and some perspectives on cold neutron interferometry using multilayer neutron mirrors developed in KUR.The purposes of our research are to develop new experimental techniques, new devices for controlling neutron spin states for opening up a new world of physics.A multilayer neutron polarizes working under a very low external magnetic field (low field magnetic mirror), Funahashi's interferometer, a cold neutron spin echo instrument, a multilayer neutron spill splitter and a cold neutron pulser were developed.The equiv- alency of the quantum precession induced by the effective gap layer of the multilayer neutron spin splitter and Larmor precession of neutron spin in a magnetic field is established.This idea allows us to develop a cold neutron phase-spin-echo interferometer (a neutron spin interferometer).The neutron spin interferometer and a cold neutron pulser enabled us to carry out the delayed choice experiment for answering the question "how the neutron wave propagates after being split by the semitransparent mirror (wave splitter)".• These matters are reviewed in this paper.•
The authors have proposed and tested a new type of multilayer cold-neutron interferometer based on a pair of etalons. The range of experimental application of conventional multilayer cold-neutron interferometer was limited due to the small spatial separation between the two coherent beams. Using etalons with an air gap of 20μm in spacing we have observed interference fringes with the contrast of (3.5 ± 0.7)%. The present results have demonstrated the feasibility of developing a cold neutron interferometer with a large path separation to carry out high precision measurements and new types of experiment.
Among the various areas of neutron optical research, neutron interferometry has provided some of the most challenging and spectacular developments. In most cases, separated coherent beams are used which are produced either by wavefront division (Young’s type) or by amplitude division (Mach− Zehnder type). These beams are subsequently coherently superposed after passing through regions of space where the neutron wavefunction is modified in phase and amplitude by various interactions: nuclear, magnetic, electromagnetic, gravitational, or by geometry and topology (as in Aharonov−Bohm-type experiments). Various types of neutron interferometers that have been tested are shown in Fig. 2.1. The first neutron interferometer was based upon wavefront division and biprism deflection, but it had several constraints for interferometric applications mainly due to the small beam separation (100 μm) (Maier-Leibnitz and Springer 1962). Nevertheless, this method gained further interest for diffraction experiments from macroscopic objects and for the detection of weak interaction effects where the long flight paths (10 m) enhance the sensitivity for the measurements of these effects (Gähler et al. 1980; Klein et al. 1981a). The perfect-crystal interferometer (Rauch et al. 1974) provides widely separated coherent beams and has become a standard method for advanced neutron optical investigations. The development of diffraction and phase grating interferometers extended the Mach-Zehnder interferometer method to very slow neutrons (loffe et al. 1985; Gruber et al. 1989). The superposition of spin-up and spin-down states in the longitudinal direction provides the basis for Larmor and Ramsey interferometry, where no lateral beam splitting is necessary. The well-known spin-echo systems (Mezei 1972) and zero-field spin-echo systems (Gähler and Golub 1987; Dubbers et al. 1989) are examples of such interferometers, which also play an important role in atom interferometry (Bord é 1989; Kasevich and Chu 1991; Riehle et al. 1991).
In this paper, we present a tutorial set-up based on an optical three-grating Mach–Zehnder interferometer. As this apparatus is very similar in its principle to the Mach–Zehnder interferometers used with matter waves (neutrons, atoms and molecules), it can be used to familiarize students with particle optics, and in our explanations, we use the complementary points of view of wave optics and particle optics. Finally, we have used this interferometer to measure the index of refraction of BK 7 glass for red light at 633 nm, with a technique equivalent to the one used to measure the index of refraction of solid matter for thermal neutrons. The dimensions of this interferometer and its cost make it very interesting for laboratory courses and the experiment described here can be reproduced by students.
We are developing large‐dimensional cold‐neutron interferometers with multilayer mirrors in order to investigate small interactions. In particular Jamin type interferometers composed of wide‐gapped “BSE”s, which divide the beam completely, can realize the precision measurement of topological Aharonov‐Casher effect. We have made a prototype with 200 μm gapped BSEs and confirmed the spatial separation of its two paths at monochromatic cold‐neutron beamline MINE2 on JRR‐3M reactor in JAEA.