Laser & Optoelectronics Progress

Optimized Condition for Buffer Gas in Cesium Atomic Magnetometer

李庆萌 Li Qingmeng, 张军海 Zhang Junhai, 曾宪金 Zeng Xianjin, 黄强 Huang Qiang, Sun Weimin

Published Jan 1, 2013• 1 citation
Publisher
DOI
10.3788/lop50.072802

Related papers

Resonance Ionization of Cesium Atoms in Presence of Buffer Gas Collisions

E. Arimondo, F. Giammanco, Antonio Sasso +1 more

Springer series in optical sciences/SPringer series in optical sciences•Jan 1, 1985•0 citations

Temperature characteristics of Rb-N2 single-beam magnetometer with different buffer gas pressures

Shaowen Zhang, Ying Zhou, Fei Lu +6 more

Measurement•Apr 9, 2023•13 citations

Buffer-gas pressure dependence of the scale factor in nonlinear magneto-optical rotation magnetometers

Zhenglong Lu, Jiali Liu, Chi Fang +5 more

Measurement•Jun 27, 2026•1 citation

Investigation on the methods to extend the transverse relaxation time of polarized alkali atoms

Yang-Ying Fu, Jie Yuan

In order to improve the sensitivity of radio-frequency atomic magnetometer, two methods to extend the transverse relaxation time of polarized alkali atoms are investigated. One way is the application of a non-relaxing coating, another way is the introduction of buffer gas into cell. A theory relaxation model is built, and the dependences of transverse relaxation time on buffer gas pressure, laser power, cell temperature, and magnetic-field gradient are obtained. The measurements of transverse relaxation time are carried out in a cesium atomic radio-frequency magnetometer. The optical experiment conditions which yield the highest sensitivity are determined in experiments. Experiments results indicate that the optimal pressure for neon is 200 Torr. The experimental results are in agreement with the theoretical ones. An ultimate sensitivity of 100 fT/Hz1/2 of the cesium atomic radio-frequency magnetometer has been achieved. This study helps further optimization of the cell performance and the sensitivity of radio-frequency atomic magnetometer.

National Conference on Laser Technology and Optoelectronics (LTO)•May 17, 2019•0 citations

Buffer-gas loaded magnetic traps for atoms and molecules: A primer

Robert deCarvalho, John M. Doyle, Břetislav Friedrich +4 more

The European Physical Journal D•Jan 1, 1999•143 citations

Magnetic trapping of transition-metal and rare-earth atoms using buffer-gas loading

Cindy Hancox

•Jan 1, 2005•4 citations
In order to improve the sensitivity of radio-frequency atomic magnetometer, two methods to extend the transverse relaxation time of polarized alkali atoms are investigated. One way is the application of a non-relaxing coating, another way is the introduction of buffer gas into cell. A theory relaxation model is built, and the dependences of transverse relaxation time on buffer gas pressure, laser power, cell temperature, and magnetic-field gradient are obtained. The measurements of transverse relaxation time are carried out in a cesium atomic radio-frequency magnetometer. The optical experiment conditions which yield the highest sensitivity are determined in experiments. Experiments results indicate that the optimal pressure for neon is 200 Torr. The experimental results are in agreement with the theoretical ones. An ultimate sensitivity of 100 fT/Hz1/2 of the cesium atomic radio-frequency magnetometer has been achieved. This study helps further optimization of the cell performance and the sensitivity of radio-frequency atomic magnetometer.