Physical Review Letters

Atom-Light Hybrid Interferometer

Bing Chen, Cheng Qiu, Shuying Chen, Jinxian Guo, L. Q. Chen, Z. Y. Ou, Weiping Zhang

Published Jul 24, 2015• 112 citations
Publisher

Abstract

A new type of hybrid atom-light interferometer is demonstrated with atomic Raman amplification processes replacing the beam splitting elements in a traditional interferometer. This nonconventional interferometer involves correlated optical and atomic waves in the two arms. The correlation between atoms and light developed with the Raman process makes this interferometer different from conventional interferometers with linear beam splitters. It is observed that the high-contrast interference fringes are sensitive to the optical phase via a path change as well as the atomic phase via a magnetic field change. This new atom-light correlated hybrid interferometer is a sensitive probe of the atomic internal state and should find wide applications in precision measurement and quantum control with atoms and photons.

DOI
10.1103/physrevlett.115.043602

Related papers

Atom–light superposition oscillation and Ramsey-like atom–light interferometer

Cheng Qiu, Shuying Chen, L. Q. Chen +4 more

Coherent wave splitting is crucial in interferometers. Normally, the waves after this splitting are of the same type. But recent progress in interaction between atom and light has led to the coherent conversion of photon to atomic excitation. This makes it possible to split an incoming light wave into a coherent superposition state of atom and light and paves the way for an interferometer made of different types of waves. Here we report on a Rabi-like coherent-superposition oscillation observed between atom and light and a coherent mixing of light wave with excited atomic spin wave in a Raman process. We construct a new kind of hybrid interferometer based on the atom-light coherent superposition state. Interference fringes are observed in both optical output intensity and atomic output in terms of the atomic spin wave strength when we scan either or both of the optical and atomic phases. Such a hybrid interferometer can be used to interrogate atomic states by optical detection and will find its applications in precision measurement and quantum control of atoms and light.

arXiv:1602.05685•Optica•Jul 12, 2016•23 citations

Quantum metrology with atom and light correlation

Feng Xiao-Tian, Chun-Hua Yuan, Chen Li-Qing +3 more

The measurement of physical quantities and measurement units standard promote the development of metrology. Especially, the developments of laser interference and atomic frequency standard bring a revolutionary leap for metrology. Many precision measurement techniques have been proposed and experimentally demonstrated, such as gravitational wave measurements and laser gyroscopes based on laser interferometry, and atomic clocks and atomic gyroscopes based on the atom interferometry. Recently, a new branch of science, quantum metrology, has grown up to further explore and exploit the quantum techniques for precision measurement of physical quantities.#br#This paper will focus on recent developments in quantum metrology and interference based on coherence and correlation of light and atom. Firstly, we briefly review the development of metrology. Then, we introduce our own researches in recent years, including quantum-correlation SU(1,1) optical interferometer based on four wave mixing process in atomic vapor and the atom-light hybrid interferometer based on Raman scattering in atomic vapor.#br#Interferometer is a powerful tool to measure physical quantities sensitive to the inference wave with high precision, and has been widely used in scientific research, industry test, navigation and guidance system. For example, the laser interferometer is able to measure optical phase sensitive quantities, including length, angular velocity, gravitational wave and so on. Meanwhile, the atom interferometer is sensitive to the change of atomic phase caused by the light, gravity, electric and magnetic fields. As a new type of interferometry, the atom-light hybrid interferometer, is sensitive to both the optical phase and atomic phase. Furthermore, SU(1,1) interferometer and nonlinear atom-light hybrid interferometer have the ability to beat the standard quantum limit of phase sensitivity. Quantum interference technology, whose phase measurement accuracy can break through the limit of standard quantum limit, is the core of quantum metrology and quantum measurement technology.

Acta Physica Sinica•Jan 1, 2018•3 citations

SU(1,1)-type light-atom-correlated interferometer

Hongmei Ma, Dong Li, Chun-Hua Yuan +3 more

The quantum correlation of light and atomic collective excitation can be used to compose an SU(1,1)-type hybrid light-atom interferometer, where one arm in the optical SU(1,1) interferometer is replaced by the atomic collective excitation. The phase-sensing probes include not only the photon field but also the atomic collective excitation inside the interferometer. For a coherent squeezed state as the phase-sensing field, the phase sensitivity can approach the Heisenberg limit under the optimal conditions. We also study the effects of the loss of light field and the dephasing of atomic excitation on the phase sensitivity. This kind of active SU(1,1) interferometer can also be realized in other systems, such as circuit quantum electrodynamics in microwave systems, which provides a different method for basic measurement using the hybrid interferometers.

arXiv:1508.02623•Physical Review A•Aug 24, 2015•15 citations

Multi-wave atom interferometer based on Doppler-insensitive Raman transition

Lele Chen, Ke Zhang, Yaoyao Xu +4 more

An atom interferometer based on Doppler-insensitive Raman transition is proposed, which has sharply peaked interference fringes for multi-wave interference. We show that two sets of counter-propagating Doppler-insensitive Raman beam pairs can be used to construct a new type of multi-wave beam splitter, which can be used to construct an atom interferometer. Although the spacing between adjacent diffraction orders of the interferometer is small, they can be distinguished by the internal state of the atom. Our analysis shows that the width of the fringes of this atom interferometer is inversely proportional to the width (duration) of the beam splitter and the Rabi frequency of the Raman beams, that is, the interferometer can achieve high resolution at high light intensity and long pulse width.

Optics Express•Feb 25, 2020•2 citations

Effects of losses in the atom-light hybrid SU(1,1) interferometer

Zhao-Dan Chen, Chun-Hua Yuan, Hongmei Ma +4 more

Collective atomic excitation can be realized by the Raman scattering. Such a photon-atom interface can form an SU(1,1)-typed atom-light hybrid interferometer, where the atomic Raman amplification processes take the place of the beam splitting elements in a traditional Mach-Zehnder interferometer. We numerically calculate the phase sensitivities and the signal-to-noise ratios (SNRs) of this interferometer with the method of homodyne detection and intensity detection, and give their differences of the optimal phase points to realize the best phase sensitivities and the maximal SNRs from these two detection methods. The difference of the effects of loss of light field and atomic decoherence on measure precision is analyzed.

arXiv:1603.03607•Optics Express•Jul 27, 2016•27 citations

Quantum metrology with parametric amplifier-based photon correlation interferometers

Florian Hudelist, Jia Kong, Cunjin Liu +3 more

Conventional interferometers usually utilize beam splitters for wave splitting and recombination. These interferometers are widely used for precision measurement. Their sensitivity for phase measurement is limited by the shot noise, which can be suppressed with squeezed states of light. Here we study a new type of interferometer in which the beam splitting and recombination elements are parametric amplifiers. We observe an improvement of 4.1±0.3 dB in signal-to-noise ratio compared with a conventional interferometer under the same operating condition, which is a 1.6-fold enhancement in rms phase measurement sensitivity beyond the shot noise limit. The improvement is due to signal enhancement. Combined with the squeezed state technique for shot noise suppression, this interferometer promises further improvement in sensitivity. Furthermore, because nonlinear processes are involved in this interferometer, we can couple a variety of different waves and form new types of hybrid interferometers, opening a door for many applications in metrology. Interferometers play a key role in precision measurements and metrology. Here, the authors demonstrate a new type of interferometer that replaces the standard beam splitter elements with parametric amplifiers, which provides enhanced performance compared with a Mach–Zehnder interferometer.

Nature Communications•Jan 29, 2014•438 citations
A new type of hybrid atom-light interferometer is demonstrated with atomic Raman amplification processes replacing the beam splitting elements in a traditional interferometer. This nonconventional interferometer involves correlated optical and atomic waves in the two arms. The correlation between atoms and light developed with the Raman process makes this interferometer different from conventional interferometers with linear beam splitters. It is observed that the high-contrast interference fringes are sensitive to the optical phase via a path change as well as the atomic phase via a magnetic field change. This new atom-light correlated hybrid interferometer is a sensitive probe of the atomic internal state and should find wide applications in precision measurement and quantum control with atoms and photons.
Coherent wave splitting is crucial in interferometers. Normally, the waves after this splitting are of the same type. But recent progress in interaction between atom and light has led to the coherent conversion of photon to atomic excitation. This makes it possible to split an incoming light wave into a coherent superposition state of atom and light and paves the way for an interferometer made of different types of waves. Here we report on a Rabi-like coherent-superposition oscillation observed between atom and light and a coherent mixing of light wave with excited atomic spin wave in a Raman process. We construct a new kind of hybrid interferometer based on the atom-light coherent superposition state. Interference fringes are observed in both optical output intensity and atomic output in terms of the atomic spin wave strength when we scan either or both of the optical and atomic phases. Such a hybrid interferometer can be used to interrogate atomic states by optical detection and will find its applications in precision measurement and quantum control of atoms and light.
The measurement of physical quantities and measurement units standard promote the development of metrology. Especially, the developments of laser interference and atomic frequency standard bring a revolutionary leap for metrology. Many precision measurement techniques have been proposed and experimentally demonstrated, such as gravitational wave measurements and laser gyroscopes based on laser interferometry, and atomic clocks and atomic gyroscopes based on the atom interferometry. Recently, a new branch of science, quantum metrology, has grown up to further explore and exploit the quantum techniques for precision measurement of physical quantities.#br#This paper will focus on recent developments in quantum metrology and interference based on coherence and correlation of light and atom. Firstly, we briefly review the development of metrology. Then, we introduce our own researches in recent years, including quantum-correlation SU(1,1) optical interferometer based on four wave mixing process in atomic vapor and the atom-light hybrid interferometer based on Raman scattering in atomic vapor.#br#Interferometer is a powerful tool to measure physical quantities sensitive to the inference wave with high precision, and has been widely used in scientific research, industry test, navigation and guidance system. For example, the laser interferometer is able to measure optical phase sensitive quantities, including length, angular velocity, gravitational wave and so on. Meanwhile, the atom interferometer is sensitive to the change of atomic phase caused by the light, gravity, electric and magnetic fields. As a new type of interferometry, the atom-light hybrid interferometer, is sensitive to both the optical phase and atomic phase. Furthermore, SU(1,1) interferometer and nonlinear atom-light hybrid interferometer have the ability to beat the standard quantum limit of phase sensitivity. Quantum interference technology, whose phase measurement accuracy can break through the limit of standard quantum limit, is the core of quantum metrology and quantum measurement technology.
The quantum correlation of light and atomic collective excitation can be used to compose an SU(1,1)-type hybrid light-atom interferometer, where one arm in the optical SU(1,1) interferometer is replaced by the atomic collective excitation. The phase-sensing probes include not only the photon field but also the atomic collective excitation inside the interferometer. For a coherent squeezed state as the phase-sensing field, the phase sensitivity can approach the Heisenberg limit under the optimal conditions. We also study the effects of the loss of light field and the dephasing of atomic excitation on the phase sensitivity. This kind of active SU(1,1) interferometer can also be realized in other systems, such as circuit quantum electrodynamics in microwave systems, which provides a different method for basic measurement using the hybrid interferometers.
An atom interferometer based on Doppler-insensitive Raman transition is proposed, which has sharply peaked interference fringes for multi-wave interference. We show that two sets of counter-propagating Doppler-insensitive Raman beam pairs can be used to construct a new type of multi-wave beam splitter, which can be used to construct an atom interferometer. Although the spacing between adjacent diffraction orders of the interferometer is small, they can be distinguished by the internal state of the atom. Our analysis shows that the width of the fringes of this atom interferometer is inversely proportional to the width (duration) of the beam splitter and the Rabi frequency of the Raman beams, that is, the interferometer can achieve high resolution at high light intensity and long pulse width.
Collective atomic excitation can be realized by the Raman scattering. Such a photon-atom interface can form an SU(1,1)-typed atom-light hybrid interferometer, where the atomic Raman amplification processes take the place of the beam splitting elements in a traditional Mach-Zehnder interferometer. We numerically calculate the phase sensitivities and the signal-to-noise ratios (SNRs) of this interferometer with the method of homodyne detection and intensity detection, and give their differences of the optimal phase points to realize the best phase sensitivities and the maximal SNRs from these two detection methods. The difference of the effects of loss of light field and atomic decoherence on measure precision is analyzed.
Conventional interferometers usually utilize beam splitters for wave splitting and recombination. These interferometers are widely used for precision measurement. Their sensitivity for phase measurement is limited by the shot noise, which can be suppressed with squeezed states of light. Here we study a new type of interferometer in which the beam splitting and recombination elements are parametric amplifiers. We observe an improvement of 4.1±0.3 dB in signal-to-noise ratio compared with a conventional interferometer under the same operating condition, which is a 1.6-fold enhancement in rms phase measurement sensitivity beyond the shot noise limit. The improvement is due to signal enhancement. Combined with the squeezed state technique for shot noise suppression, this interferometer promises further improvement in sensitivity. Furthermore, because nonlinear processes are involved in this interferometer, we can couple a variety of different waves and form new types of hybrid interferometers, opening a door for many applications in metrology. Interferometers play a key role in precision measurements and metrology. Here, the authors demonstrate a new type of interferometer that replaces the standard beam splitter elements with parametric amplifiers, which provides enhanced performance compared with a Mach–Zehnder interferometer.