Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Chemical Physics Letters

Reply to the comment on “Quantum trajectory tests of radical-pair quantum dynamics in CIDNP measurements of photosynthetic reaction centers” by G. Jeschke

Iannis K. Kominis

Published Feb 15, 2016• 4 citations
Publisher
DOI
10.1016/j.cplett.2016.02.015

Related papers

Comment on “Quantum trajectory tests of radical-pair quantum dynamics in CIDNP measurements of photosynthetic reaction centers” [Chem. Phys. Lett. 640 (2015) 40–45]

Gunnar Jeschke

Chemical Physics Letters•Feb 13, 2016•5 citations

Quantum teleportation across a biological membrane by means of correlated spin pair dynamics in photosynthetic reaction centers

К. М. Салихов, John H. Golbeck, Dietmar Stehlik

Applied Magnetic Resonance•Mar 1, 2007•42 citations

Spin-selective reactions of radical pairs act as quantum measurements

Jonathan A. Jones, Peter J. Hore

arXiv:1002.2377•Chemical Physics Letters•Feb 2, 2010•113 citations

Numerical Simulation of Quantum Teleportation Across Biological Membrane in Photosynthetic Reaction Centers

Yuri E. Kandrashkin, К. М. Салихов

Applied Magnetic Resonance•Nov 11, 2009•25 citations

Response to “Comment on ‘Equivalence of two approaches for quantum-classical hybrid systems’ ” [J. Chem. Phys. 131, 127101 (2009)]

Fei Zhan, Yuan Lin, Biao Wu

The Journal of Chemical Physics•Sep 28, 2009•0 citations

Quantum-limited biochemical magnetometers designed using the Fisher information and quantum reaction control

K. M. Vitalis, Iannis K. Kominis

Radical-ion pairs and their reactions have triggered the study of quantum effects in biological systems. This is because they exhibit a number of effects best understood within quantum information science, and at the same time are central in understanding the avian magnetic compass and the spin transport dynamics in photosynthetic reaction centers. Here we address radical-pair reactions from the perspective of quantum metrology. Since the coherent spin motion of radical pairs is effected by an external magnetic field, these spin-dependent reactions essentially realize a biochemical magnetometer. Using the quantum Fisher information, we find the fundamental quantum limits to the magnetic sensitivity of radical-pair magnetometers, arriving at a sensitivity $\ensuremath{\delta}B=2\phantom{\rule{0.16em}{0ex}}\mathrm{pT}/\ensuremath{\tau}[1\phantom{\rule{0.16em}{0ex}}\ensuremath{\mu}\text{s}]\sqrt{{\ensuremath{\nu}}_{0}[{10}^{12}]}$, given in terms of radical-pair lifetime $\ensuremath{\tau}$ and number of radical pairs ${\ensuremath{\nu}}_{0}$. We then explore how well the usual measurement scheme considered in radical-pair reactions, the measurement of reaction yields, approaches the fundamental limits. In doing so, we find the optimal hyperfine interaction Hamiltonian that leads to the best magnetic sensitivity as obtained from reaction yields. This is still an order of magnitude smaller than the absolute quantum limit. Finally, we demonstrate that with a realistic quantum reaction control reminding one of Ramsey interferometry, here presented as a quantum circuit involving the spin-exchange interaction and a recently proposed molecular switch, we can approach the fundamental quantum limit within a factor of 2. This work opens the application of well-advanced quantum metrology methods to biological systems.

arXiv:1611.08902•Physical Review A•Mar 27, 2017•19 citations
Radical-ion pairs and their reactions have triggered the study of quantum effects in biological systems. This is because they exhibit a number of effects best understood within quantum information science, and at the same time are central in understanding the avian magnetic compass and the spin transport dynamics in photosynthetic reaction centers. Here we address radical-pair reactions from the perspective of quantum metrology. Since the coherent spin motion of radical pairs is effected by an external magnetic field, these spin-dependent reactions essentially realize a biochemical magnetometer. Using the quantum Fisher information, we find the fundamental quantum limits to the magnetic sensitivity of radical-pair magnetometers, arriving at a sensitivity $\ensuremath{\delta}B=2\phantom{\rule{0.16em}{0ex}}\mathrm{pT}/\ensuremath{\tau}[1\phantom{\rule{0.16em}{0ex}}\ensuremath{\mu}\text{s}]\sqrt{{\ensuremath{\nu}}_{0}[{10}^{12}]}$, given in terms of radical-pair lifetime $\ensuremath{\tau}$ and number of radical pairs ${\ensuremath{\nu}}_{0}$. We then explore how well the usual measurement scheme considered in radical-pair reactions, the measurement of reaction yields, approaches the fundamental limits. In doing so, we find the optimal hyperfine interaction Hamiltonian that leads to the best magnetic sensitivity as obtained from reaction yields. This is still an order of magnitude smaller than the absolute quantum limit. Finally, we demonstrate that with a realistic quantum reaction control reminding one of Ramsey interferometry, here presented as a quantum circuit involving the spin-exchange interaction and a recently proposed molecular switch, we can approach the fundamental quantum limit within a factor of 2. This work opens the application of well-advanced quantum metrology methods to biological systems.