Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Off-axis cavity ring down spectroscopy with exponential and phase shift detection : absorption spectra of weak transitions at low temperatures.

Yasnahir Perez-Delgado

Published Aug 1, 2009• 1 citation
OpenAlex

Related papers

Theoretical detection limit of saturated absorption cavity ring-down spectroscopy (SCAR) and two-photon absorption cavity ring-down spectroscopy

Kevin K. Lehmann

Applied Physics B•Oct 10, 2013•24 citations

Differential cavity mode spectroscopy: A new cavity enhanced technique for the detection of weak transitions

Glenn de Vine, David E. McClelland, Malcolm B. Gray

Physics Letters A•May 9, 2008•1 citation

Rapid scanning cavity ring-down spectroscopy at the quantum noise limit

David A. Long, Adam J. Fleisher, Szymon Wójtewicz +2 more

We present an ultrasensitive cavity-enhanced technique for probing weak molecular absorptions. Recently, we have implemented heterodyne detection, which allowed for quantum-noise-limited detection and noise-equivalent absorption coefficients as low as 6×10−14 cm−1•Hz−1/2.

•Jan 1, 2014•0 citations

Cavity enhanced non-linear spectroscopy of ultra-narrow optical transitions

Dominic Meiser, Michael J. Martin, Jun Ye +1 more

Bulletin of the American Physical Society•Jun 16, 2011•0 citations

Optical feedback frequency stabilized cavity ring-down spectroscopy

Johannes Burkart, D. Romanini, S. Kassi

We introduce optical feedback frequency stabilized cavity ring-down spectroscopy (OFFS-CRDS), a near-shot-noise-limited technique that combines kilohertz resolution with an absorption detection sensitivity of 5×10(-13) cm(-1) Hz(-1/2). Its distributed feedback laser source is stabilized to a highly stable V-shaped reference cavity by optical feedback and fine-tuned by means of single-sideband modulation. The stability of this narrow laser is transferred to a ring-down (RD) cavity using a new fibered Pound-Drever-Hall (PDH) locking scheme without a dedicated electro-optic phase modulator, yielding several hundred RD events per second. We demonstrate continuous coverage of more than 7 nm with a baseline noise of 5×10(-12) cm(-1) and a dynamic range spanning six decades. With its resonant intracavity light intensity on the order of 1 kW/cm2, the spectrometer was used for observing a Lamb dip in a transition of carbon dioxide involving four vibrational quanta. Saturating such a weak transition at 160 μW input power, OFFS-CRDS paves the way to Doppler-free molecular overtone spectroscopy for precision measurements of hyperfine structures and pressure shifts.

Optics Letters•Aug 4, 2014•61 citations

Cavity Ring-down Spectroscopy with behavior of Hybrid Cavity Structures

Muhammad Junaid Khan, Rida Batool Sheraliyat

Cavity ring-down (CRD) spectroscopy represents a direct absorption technique of sample absorption measurement. Instead of measuring the amount of the absorbed light, this technique determines the rate at which light intensity decays inside an optical cavity. When using a pulsed or continuous-wave light source, CRD spectroscopy offers considerably higher sensitivity as compared with conventional spectroscopy of absorption, making even very weak absorptions easy to detect.

physics.opticsCross-listedarXiv:2512.12241•Dec 16, 2025
We introduce optical feedback frequency stabilized cavity ring-down spectroscopy (OFFS-CRDS), a near-shot-noise-limited technique that combines kilohertz resolution with an absorption detection sensitivity of 5×10(-13) cm(-1) Hz(-1/2). Its distributed feedback laser source is stabilized to a highly stable V-shaped reference cavity by optical feedback and fine-tuned by means of single-sideband modulation. The stability of this narrow laser is transferred to a ring-down (RD) cavity using a new fibered Pound-Drever-Hall (PDH) locking scheme without a dedicated electro-optic phase modulator, yielding several hundred RD events per second. We demonstrate continuous coverage of more than 7 nm with a baseline noise of 5×10(-12) cm(-1) and a dynamic range spanning six decades. With its resonant intracavity light intensity on the order of 1 kW/cm2, the spectrometer was used for observing a Lamb dip in a transition of carbon dioxide involving four vibrational quanta. Saturating such a weak transition at 160 μW input power, OFFS-CRDS paves the way to Doppler-free molecular overtone spectroscopy for precision measurements of hyperfine structures and pressure shifts.