Conference on Lasers and Electro-Optics Pacific Rim (CLEO-PR)

Generation of time-bin entangled photon pairs utilizing coherence revival property of a CW multi-mode laser

Osung Kwon, Kwang-Kyoon Park, Young-Sik Ra, Yong‐Su Kim, Yoon-Ho Kim

Published Aug 1, 2015• 0 citations
Publisher

Abstract

We report another regime for generation of time-bin entangled photon pairs and demonstrate the scheme experimentally. In our scheme, the photon pairs are pumped by a cw multi-mode laser having coherence revival property.
DOI
10.1109/cleopr.2015.7376509

Related papers

Time-bin entangled photon pairs from spontaneous parametric down-conversion pumped by a cw multi-mode diode laser

Osung Kwon, Kwang-Kyoon Park, Young-Sik Ra +2 more

Generation of time-bin entangled photon pairs requires the use of the Franson interferometer which consists of two spatially separated unbalanced Mach-Zehnder interferometers through which the signal and idler photons from spontaneous parametric down-conversion (SPDC) are made to transmit individually. There have been two SPDC pumping regimes where the scheme works: the narrowband regime and the double-pulse regime. In the narrowband regime, the SPDC process is pumped by a narrowband cw laser with the coherence length much longer than the path length difference of the Franson interferometer. In the double-pulse regime, the longitudinal separation between the pulse pair is made equal to the path length difference of the Franson interferometer. In this paper, we propose another regime by which the generation of time-bin entanglement is possible and demonstrate the scheme experimentally. In our scheme, differently from the previous approaches, the SPDC process is pumped by a cw multi-mode (i.e., short coherence length) laser and makes use of the coherence revival property of such a laser. The high-visibility two-photon Franson interference demonstrates clearly that high-quality time-bin entanglement source can be developed using inexpensive cw multi-mode diode lasers for various quantum communication applications.

Optics Express•Oct 17, 2013•41 citations

Time-bin entangled photon pairs from spontaneous parametric down-conversion pumped by a cw multi-mode diode laser

Osung Kwon, Kwang-Kyoon Park, Young-Sik Ra +2 more

The Franson interferometer consists of two spatially separated unbalanced Mach-Zehnder interferometers through which the signal and the idler photons from spontaneous parametric down-conversion (SPDC) are made to transmit. It is often used to prepare time-bin entanglement of two photons in the two SPDC pumping regimes: the narrowband regime and the double-pulse regime. In the narrowband regime, the SPDC process is pumped by a narrowband cw laser with the coherence length much longer than the path length difference of the Franson interferometer. In the double-pulse regime, the longitudinal separation between the pulse pair is made equal to the path length difference of the Franson interferometer. In this paper, we propose another regime by which the generation of time-bin entanglement is possible and demonstrate the scheme experimentally.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Mar 4, 2015•0 citations

Generation of time-bin-entangled photons without temporal postselection

Alessandro Rossi, Giuseppe Vallone, F. De Martini +1 more

We report on the implementation of an interferometric scheme that allows the generation of photon pairs entangled in the time-energy degree of freedom. This scheme does not require any kind of temporal postselection on the generated pairs and can be used even with lasers with short coherence time.

arXiv:0805.1682•Physical Review A•Jul 23, 2008•24 citations

Properties of entangled photon pairs generated by a CW laser with small coherence time: theory and experiment

S. Cialdi, F. Castelli, Matteo G. A. Paris

The generation of entangled photon pairs by parametric down-conversion from solid state CW lasers with small coherence time is theoretically and experimentally analyzed. We consider a compact and low-cost setup based on a two-crystal scheme with Type-I phase matching. We study the effect of the pump coherence time over the entangled state visibility and over the violation of Bell's inequality, as a function of the crystal length. The full density matrix is reconstructed by quantum tomography. The proposed theoretical model is verified using a purification protocol based on a compensation crystal.

arXiv:0802.3131•Journal of Modern Optics•Jan 16, 2009•18 citations

Three-photon time-bin entanglement generation using an optical switch

Hsin-Pin Lo, Takuya Ikuta, Koji Azuma +3 more

We realized the first three-photon time-bin GHZ states using a 2×2 optical switch as a time-dependent beam splitter to entangle a photon from a weak coherent light and a photon from a time-bin entangled photon pair.

Conference on Lasers and Electro-Optics Pacific Rim (CLEO-PR)•Jan 1, 2022•0 citations

Three-Photon Time-Bin Entanglement Generation using an Optical Switch

Hsin-Pin Lo, Takuya Ikuta, Koji Azuma +3 more

We realized the first three-photon time-bin GHZ states using a 2 × 2 optical switch as a time-dependent beam splitter to entangle a photon from a weak coherent light and a photon from a time-bin entangled photon pair.

Conference on Lasers and Electro-Optics Pacific Rim (CLEO-PR)•Jul 31, 2022•0 citations
Generation of time-bin entangled photon pairs requires the use of the Franson interferometer which consists of two spatially separated unbalanced Mach-Zehnder interferometers through which the signal and idler photons from spontaneous parametric down-conversion (SPDC) are made to transmit individually. There have been two SPDC pumping regimes where the scheme works: the narrowband regime and the double-pulse regime. In the narrowband regime, the SPDC process is pumped by a narrowband cw laser with the coherence length much longer than the path length difference of the Franson interferometer. In the double-pulse regime, the longitudinal separation between the pulse pair is made equal to the path length difference of the Franson interferometer. In this paper, we propose another regime by which the generation of time-bin entanglement is possible and demonstrate the scheme experimentally. In our scheme, differently from the previous approaches, the SPDC process is pumped by a cw multi-mode (i.e., short coherence length) laser and makes use of the coherence revival property of such a laser. The high-visibility two-photon Franson interference demonstrates clearly that high-quality time-bin entanglement source can be developed using inexpensive cw multi-mode diode lasers for various quantum communication applications.
The Franson interferometer consists of two spatially separated unbalanced Mach-Zehnder interferometers through which the signal and the idler photons from spontaneous parametric down-conversion (SPDC) are made to transmit. It is often used to prepare time-bin entanglement of two photons in the two SPDC pumping regimes: the narrowband regime and the double-pulse regime. In the narrowband regime, the SPDC process is pumped by a narrowband cw laser with the coherence length much longer than the path length difference of the Franson interferometer. In the double-pulse regime, the longitudinal separation between the pulse pair is made equal to the path length difference of the Franson interferometer. In this paper, we propose another regime by which the generation of time-bin entanglement is possible and demonstrate the scheme experimentally.
The generation of entangled photon pairs by parametric down-conversion from solid state CW lasers with small coherence time is theoretically and experimentally analyzed. We consider a compact and low-cost setup based on a two-crystal scheme with Type-I phase matching. We study the effect of the pump coherence time over the entangled state visibility and over the violation of Bell's inequality, as a function of the crystal length. The full density matrix is reconstructed by quantum tomography. The proposed theoretical model is verified using a purification protocol based on a compensation crystal.