Continuous Observation of Rabi Oscillations in a Josephson Flux Qubit

E. V. Il’ichev, Nikolai Oukhanski, A. Izmalkov, Th. Wagner, M. Grajcar, H.‐G. Meyer, Anatoly Yu. Smirnov, Alec Maassen van den Brink, M. H. S. Amin, Alexandre M. Zagoskin

Published Mar 20, 2003• 1 citation
OpenAlex

Abstract

Under resonant irradiation, a quantum system can undergo coherent (Rabi) oscillations in time. We report their first_continuous_ observation in a three-Josephson-junction flux qubit, coupled to a high-quality tank circuit tuned to the Rabi frequency. In addition to robustness and simplicity, this method of_Rabi spectroscopy_ enabled a long coherence time of about 2.5microseconds, corresponding to an effective qubit quality factor ~7000.

Related papers

Continuous Monitoring of Rabi Oscillations in a Josephson Flux Qubit

Evgeni V. Il’ichev, Nikolai Oukhanski, A. Izmalkov +7 more

Under resonant irradiation, a quantum system can undergo coherent (Rabi) oscillations in time. We report evidence for such oscillations in a continuously observed three-Josephson-junction flux qubit, coupled to a high-quality tank circuit tuned to the Rabi frequency. In addition to simplicity, this method of Rabi spectroscopy enabled a long coherence time of about 2.5 micros, corresponding to an effective qubit quality factor approximately 7000.

arXiv:cond-mat/0303433•Physical Review Letters•Aug 28, 2003•147 citations

Method for direct observation of coherent quantum oscillations in a superconducting phase qubit

Ya. S. Greenberg, A. Izmalkov, M. Grajcar +3 more

Time-domain observations of coherent oscillations between quantum states in mesoscopic superconducting systems have so far been restricted to restoring the time-dependent probability distribution from the readout statistics. We propose a method for direct observation of Rabi oscillations in a phase qubit. The external source, typically in GHz range, induces transitions between the qubit levels. The resulting Rabi oscillations of supercurrent in the qubit loop induce the voltage oscillations across the coil of a high quality resonant tank circuit, inductively coupled to the phase qubit. It is the presence of these voltage oscillations in the detected signal which reveals the existence of Rabi oscillations in the qubit. A detailed calculation for zero and nonzero temperatures are made for the case of persistent current qubit. According to the estimates for decoherence and relaxation times, the effect can be detected using conventional rf circuitry, with Rabi frequency in the MHz range.

arXiv:cond-mat/0208143•Physical review. B, Condensed matter•Dec 31, 2002•25 citations

Method for direct observation of coherent quantum oscillations in a superconducting phase qubit: Computer simulations

Ya. S. Greenberg

Time-domain observations of coherent oscillations between quantum states in mesoscopic superconducting systems have so far been restricted to restoring the time-dependent probability distribution from the readout statistics. We propose a method for direct observation of Rabi oscillations in a phase qubit. The external source, typically in the GHz range, induces transitions between the qubit levels. The resulting Rabi oscillations of supercurrent in the qubit loop are detected by a high-quality resonant tank circuit, inductively coupled to the phase qubit. Here we present the results of detailed computer simulations of the interaction of a classical object (resonant tank circuit) with a quantum object (phase qubit), which explicitly account for the back action of a tank circuit. According to the results of our simulations the Rabi oscillations in the MHz range can be detected using the conventional NMR pulse Fourier technique.

arXiv:cond-mat/0303049•Physical review. B, Condensed matter•Dec 30, 2003•7 citations

Spectroscopy and coherent manipulation of single and coupled flux qubits

Yulin Wu, Hui Deng, Keqiang Huang +7 more

Measurements of three-junction flux qubits, both single flux qubits and coupled flux qubits, using a coupled direct current superconducting quantum interference device (dc-SQUID) for readout are reported. The measurement procedure is described in detail. We performed spectroscopy measurements and coherent manipulations of the qubit states on a single flux qubit, demonstrating quantum energy levels and Rabi oscillations, with Rabi oscillation decay time T Rabi = 78 ns and energy relaxation time T 1 = 315 ns. We found that the value of T Rabi depends strongly on the mutual inductance between the qubit and the magnetic coil. We also performed spectroscopy measurements on inductively coupled flux qubits.

Chinese Physics B•Sep 1, 2013•3 citations

Pseudo-Rabi oscillations in superconducting flux qubits in the classical regime

A. N. Omelyanchouk, Sergey N Shevchenko, Alexandre M. Zagoskin +2 more

Nonlinear effects in mesoscopic devices can have both quantum and classical origins. We show that a three-Josephson-junction (3JJ) flux qubit in the classical regime can produce low-frequency oscillations in the presence of an external field in resonance with the (high-frequency) harmonic mode $\ensuremath{\omega}$ of the system. Like in the case of quantum Rabi oscillations, the frequency of these pseudo-Rabi oscillations is much smaller than $\ensuremath{\omega}$ and scales approximately linearly with the amplitude of the external field. This classical effect can be reliably distinguished from its quantum counterpart because it can be produced by the external drive not only at the resonance frequency $\ensuremath{\omega}$ and its subharmonics $(\ensuremath{\omega}/n)$, but also at its overtones, $n\ensuremath{\omega}$.

arXiv:0705.1768•Physical Review B•Aug 15, 2008•12 citations

Rabi spectroscopy for a two-level system

Ya. S. Greenberg, E. V. Il’ichev

We have analyzed the interaction of a dissipative two level quantum system with high and low frequency excitation. The system is continuously and simultaneously irradiated by these two waves. If the frequency of the first signal is close to the level separation and the second one is tuned to the Rabi frequency, it is shown that the response of the system exhibits an undamped low frequency oscillation. The method can be useful for low frequency Rabi spectroscopy in various physical systems which are described by a two level Hamiltonian, such as nuclei spins in NMR, double well quantum dots, superconducting flux and charge qubits, etc. As an example, the application of the method to the readout of a flux qubit is considered.

arXiv:quant-ph/0502187•Feb 28, 2005•0 citations
Under resonant irradiation, a quantum system can undergo coherent (Rabi) oscillations in time. We report their first_continuous_ observation in a three-Josephson-junction flux qubit, coupled to a high-quality tank circuit tuned to the Rabi frequency. In addition to robustness and simplicity, this method of_Rabi spectroscopy_ enabled a long coherence time of about 2.5microseconds, corresponding to an effective qubit quality factor ~7000.
Time-domain observations of coherent oscillations between quantum states in mesoscopic superconducting systems have so far been restricted to restoring the time-dependent probability distribution from the readout statistics. We propose a method for direct observation of Rabi oscillations in a phase qubit. The external source, typically in GHz range, induces transitions between the qubit levels. The resulting Rabi oscillations of supercurrent in the qubit loop induce the voltage oscillations across the coil of a high quality resonant tank circuit, inductively coupled to the phase qubit. It is the presence of these voltage oscillations in the detected signal which reveals the existence of Rabi oscillations in the qubit. A detailed calculation for zero and nonzero temperatures are made for the case of persistent current qubit. According to the estimates for decoherence and relaxation times, the effect can be detected using conventional rf circuitry, with Rabi frequency in the MHz range.
Time-domain observations of coherent oscillations between quantum states in mesoscopic superconducting systems have so far been restricted to restoring the time-dependent probability distribution from the readout statistics. We propose a method for direct observation of Rabi oscillations in a phase qubit. The external source, typically in the GHz range, induces transitions between the qubit levels. The resulting Rabi oscillations of supercurrent in the qubit loop are detected by a high-quality resonant tank circuit, inductively coupled to the phase qubit. Here we present the results of detailed computer simulations of the interaction of a classical object (resonant tank circuit) with a quantum object (phase qubit), which explicitly account for the back action of a tank circuit. According to the results of our simulations the Rabi oscillations in the MHz range can be detected using the conventional NMR pulse Fourier technique.
Measurements of three-junction flux qubits, both single flux qubits and coupled flux qubits, using a coupled direct current superconducting quantum interference device (dc-SQUID) for readout are reported. The measurement procedure is described in detail. We performed spectroscopy measurements and coherent manipulations of the qubit states on a single flux qubit, demonstrating quantum energy levels and Rabi oscillations, with Rabi oscillation decay time T Rabi = 78 ns and energy relaxation time T 1 = 315 ns. We found that the value of T Rabi depends strongly on the mutual inductance between the qubit and the magnetic coil. We also performed spectroscopy measurements on inductively coupled flux qubits.
Nonlinear effects in mesoscopic devices can have both quantum and classical origins. We show that a three-Josephson-junction (3JJ) flux qubit in the classical regime can produce low-frequency oscillations in the presence of an external field in resonance with the (high-frequency) harmonic mode $\ensuremath{\omega}$ of the system. Like in the case of quantum Rabi oscillations, the frequency of these pseudo-Rabi oscillations is much smaller than $\ensuremath{\omega}$ and scales approximately linearly with the amplitude of the external field. This classical effect can be reliably distinguished from its quantum counterpart because it can be produced by the external drive not only at the resonance frequency $\ensuremath{\omega}$ and its subharmonics $(\ensuremath{\omega}/n)$, but also at its overtones, $n\ensuremath{\omega}$.
We have analyzed the interaction of a dissipative two level quantum system with high and low frequency excitation. The system is continuously and simultaneously irradiated by these two waves. If the frequency of the first signal is close to the level separation and the second one is tuned to the Rabi frequency, it is shown that the response of the system exhibits an undamped low frequency oscillation. The method can be useful for low frequency Rabi spectroscopy in various physical systems which are described by a two level Hamiltonian, such as nuclei spins in NMR, double well quantum dots, superconducting flux and charge qubits, etc. As an example, the application of the method to the readout of a flux qubit is considered.