Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:cond-mat/0208143 · Physical review. B, Condensed matter

Method for direct observation of coherent quantum oscillations in a superconducting phase qubit

Ya. S. Greenberg, A. Izmalkov, M. Grajcar, Evgeni V. Il’ichev, Wolfram Krech, H.‐G. Meyer

Published Dec 31, 2002• 25 citations
arXivHTMLPDF

Abstract

Time-domain observations of coherent oscillations between quantum states in mesoscopic superconducting systems have so far been restricted to restoring the time-dependent probability distribution from the readout statistics. We propose a method for direct observation of Rabi oscillations in a phase qubit. The external source, typically in GHz range, induces transitions between the qubit levels. The resulting Rabi oscillations of supercurrent in the qubit loop induce the voltage oscillations across the coil of a high quality resonant tank circuit, inductively coupled to the phase qubit. It is the presence of these voltage oscillations in the detected signal which reveals the existence of Rabi oscillations in the qubit. A detailed calculation for zero and nonzero temperatures are made for the case of persistent current qubit. According to the estimates for decoherence and relaxation times, the effect can be detected using conventional rf circuitry, with Rabi frequency in the MHz range.

DOI
10.1103/physrevb.66.224511

Related papers

Method for direct observation of coherent quantum oscillations in a superconducting phase qubit: Computer simulations

Ya. S. Greenberg

Time-domain observations of coherent oscillations between quantum states in mesoscopic superconducting systems have so far been restricted to restoring the time-dependent probability distribution from the readout statistics. We propose a method for direct observation of Rabi oscillations in a phase qubit. The external source, typically in the GHz range, induces transitions between the qubit levels. The resulting Rabi oscillations of supercurrent in the qubit loop are detected by a high-quality resonant tank circuit, inductively coupled to the phase qubit. Here we present the results of detailed computer simulations of the interaction of a classical object (resonant tank circuit) with a quantum object (phase qubit), which explicitly account for the back action of a tank circuit. According to the results of our simulations the Rabi oscillations in the MHz range can be detected using the conventional NMR pulse Fourier technique.

arXiv:cond-mat/0303049•Physical review. B, Condensed matter•Dec 30, 2003•7 citations

Continuous Observation of Rabi Oscillations in a Josephson Flux Qubit

E. V. Il’ichev, Nikolai Oukhanski, A. Izmalkov +7 more

Under resonant irradiation, a quantum system can undergo coherent (Rabi) oscillations in time. We report their first_continuous_ observation in a three-Josephson-junction flux qubit, coupled to a high-quality tank circuit tuned to the Rabi frequency. In addition to robustness and simplicity, this method of_Rabi spectroscopy_ enabled a long coherence time of about 2.5microseconds, corresponding to an effective qubit quality factor ~7000.

•Mar 20, 2003•1 citation

Continuous Monitoring of Rabi Oscillations in a Josephson Flux Qubit

Evgeni V. Il’ichev, Nikolai Oukhanski, A. Izmalkov +7 more

Under resonant irradiation, a quantum system can undergo coherent (Rabi) oscillations in time. We report evidence for such oscillations in a continuously observed three-Josephson-junction flux qubit, coupled to a high-quality tank circuit tuned to the Rabi frequency. In addition to simplicity, this method of Rabi spectroscopy enabled a long coherence time of about 2.5 micros, corresponding to an effective qubit quality factor approximately 7000.

arXiv:cond-mat/0303433•Physical Review Letters•Aug 28, 2003•147 citations

Spectroscopy and coherent manipulation of single and coupled flux qubits

Yulin Wu, Hui Deng, Keqiang Huang +7 more

Measurements of three-junction flux qubits, both single flux qubits and coupled flux qubits, using a coupled direct current superconducting quantum interference device (dc-SQUID) for readout are reported. The measurement procedure is described in detail. We performed spectroscopy measurements and coherent manipulations of the qubit states on a single flux qubit, demonstrating quantum energy levels and Rabi oscillations, with Rabi oscillation decay time T Rabi = 78 ns and energy relaxation time T 1 = 315 ns. We found that the value of T Rabi depends strongly on the mutual inductance between the qubit and the magnetic coil. We also performed spectroscopy measurements on inductively coupled flux qubits.

Chinese Physics B•Sep 1, 2013•3 citations

Quantum Dynamics of the Interferometer-Type Charge Qubit Under Microwave Irradiation

Wolfram Krech, Detlef Born, V. I. Shnyrkov +5 more

We study theoretically dynamic properties of an interferometer-type Josephson charge qubit consisting of a single-Cooper-pair transistor (with capacitive gate) closed by a superconducting inductive loop. Analyzing the radio frequency response of the device to microwave fields within a two-band model, we present basic features of a method for observation of various Rabi oscillation modes. For this purpose, we apply the dressed-state approach in conjunction with the rotating-wave approximation to the strongly driven quantum bit. We demonstrate the existence of multiphoton excitations and Rabi frequency transitions between quantum levels connected with them. The resulting oscillations of the supercurrent in the interferometer modify the spectral loop susceptibility. This effect may be detected via the coil of a high-quality tank circuit inductively coupled to the qubit by measuring the tank-qubit impedance variations belonging to it.

IEEE Transactions on Applied Superconductivity•Jun 1, 2005•6 citations

Theory of weak continuous measurements in a strongly driven quantum bit

Anatoly Yu. Smirnov

Continuous spectroscopic measurements of a strongly driven superconducting qubit by means of a high-quality tank circuit (a linear detector) are under study. Output functions of the detector---namely, a spectrum of voltage fluctuations and an impedance---are expressed in terms of the qubit spectrum and magnetic susceptibility. The nonequilibrium spectrum of the current fluctuations in the qubit loop and the linear response function of the driven qubit coupled to a heat bath are calculated with Bloch-Redfield and rotating-wave approximations. Back-action effects of the qubit on the tank and the tank on the qubit are analyzed quantitatively. We show that the voltage spectrum of the tank provides detailed information about the frequency and decay rate of Rabi oscillations in the qubit. It is found that both an efficiency of spectroscopic measurement and measurement-induced decoherence of the qubit demonstrate a resonant behavior as the Rabi frequency approaches the resonant frequency of the tank. We determine conditions when the spectroscopic observation of the Rabi oscillations in the flux qubit with the tank circuit can be considered as a weak continuous quantum measurement.

arXiv:cond-mat/0306004•Physical review. B, Condensed matter•Oct 17, 2003•38 citations
Time-domain observations of coherent oscillations between quantum states in mesoscopic superconducting systems have so far been restricted to restoring the time-dependent probability distribution from the readout statistics. We propose a method for direct observation of Rabi oscillations in a phase qubit. The external source, typically in GHz range, induces transitions between the qubit levels. The resulting Rabi oscillations of supercurrent in the qubit loop induce the voltage oscillations across the coil of a high quality resonant tank circuit, inductively coupled to the phase qubit. It is the presence of these voltage oscillations in the detected signal which reveals the existence of Rabi oscillations in the qubit. A detailed calculation for zero and nonzero temperatures are made for the case of persistent current qubit. According to the estimates for decoherence and relaxation times, the effect can be detected using conventional rf circuitry, with Rabi frequency in the MHz range.
Time-domain observations of coherent oscillations between quantum states in mesoscopic superconducting systems have so far been restricted to restoring the time-dependent probability distribution from the readout statistics. We propose a method for direct observation of Rabi oscillations in a phase qubit. The external source, typically in the GHz range, induces transitions between the qubit levels. The resulting Rabi oscillations of supercurrent in the qubit loop are detected by a high-quality resonant tank circuit, inductively coupled to the phase qubit. Here we present the results of detailed computer simulations of the interaction of a classical object (resonant tank circuit) with a quantum object (phase qubit), which explicitly account for the back action of a tank circuit. According to the results of our simulations the Rabi oscillations in the MHz range can be detected using the conventional NMR pulse Fourier technique.
Measurements of three-junction flux qubits, both single flux qubits and coupled flux qubits, using a coupled direct current superconducting quantum interference device (dc-SQUID) for readout are reported. The measurement procedure is described in detail. We performed spectroscopy measurements and coherent manipulations of the qubit states on a single flux qubit, demonstrating quantum energy levels and Rabi oscillations, with Rabi oscillation decay time T Rabi = 78 ns and energy relaxation time T 1 = 315 ns. We found that the value of T Rabi depends strongly on the mutual inductance between the qubit and the magnetic coil. We also performed spectroscopy measurements on inductively coupled flux qubits.
We study theoretically dynamic properties of an interferometer-type Josephson charge qubit consisting of a single-Cooper-pair transistor (with capacitive gate) closed by a superconducting inductive loop. Analyzing the radio frequency response of the device to microwave fields within a two-band model, we present basic features of a method for observation of various Rabi oscillation modes. For this purpose, we apply the dressed-state approach in conjunction with the rotating-wave approximation to the strongly driven quantum bit. We demonstrate the existence of multiphoton excitations and Rabi frequency transitions between quantum levels connected with them. The resulting oscillations of the supercurrent in the interferometer modify the spectral loop susceptibility. This effect may be detected via the coil of a high-quality tank circuit inductively coupled to the qubit by measuring the tank-qubit impedance variations belonging to it.
Continuous spectroscopic measurements of a strongly driven superconducting qubit by means of a high-quality tank circuit (a linear detector) are under study. Output functions of the detector---namely, a spectrum of voltage fluctuations and an impedance---are expressed in terms of the qubit spectrum and magnetic susceptibility. The nonequilibrium spectrum of the current fluctuations in the qubit loop and the linear response function of the driven qubit coupled to a heat bath are calculated with Bloch-Redfield and rotating-wave approximations. Back-action effects of the qubit on the tank and the tank on the qubit are analyzed quantitatively. We show that the voltage spectrum of the tank provides detailed information about the frequency and decay rate of Rabi oscillations in the qubit. It is found that both an efficiency of spectroscopic measurement and measurement-induced decoherence of the qubit demonstrate a resonant behavior as the Rabi frequency approaches the resonant frequency of the tank. We determine conditions when the spectroscopic observation of the Rabi oscillations in the flux qubit with the tank circuit can be considered as a weak continuous quantum measurement.