Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Bulletin of the American Physical Society

Dispersive measurement of a metastable phase qubit using a tunable cavity

Jed D. Whittaker

Published Jan 1, 2012• 0 citations
OpenAlex

Abstract

A metastable phase qubit was measured using a tunable cavity by two methods: a tunneling measurement followed by magnetometry readout by the cavity, and a non destructive dispersive measurement of the qubit by the cavity. The Purcell effect was observed as a decrease in the energy relaxation time of the qubit in the vicinity of the cavity, and could be manipulated by dynamically tuning the cavity. The observed dispersive shift of the cavity did not match the two-level system model for nonlinear qubits. Instead, a three-level model of the qubit was needed to describe the data, necessitated by the weakly nonlinear nature of the metastable phase qubit. The cavity was also used to directly observe the photons radiated by a tunneling measurement.

Related papers

Tunable-cavity QED with phase qubits

Jed D. Whittaker, F. C. S. da Silva, Michael S. Allman +6 more

We describe a tunable-cavity quantum electrodynamics (QED) architecture with an rf SQUID phase qubit inductively coupled to a single-mode, resonant cavity with a tunable frequency that allows for both microwave readout of tunneling and dispersive measurements of the qubit. Dispersive measurement is well characterized by a three-level model, strongly dependent on qubit anharmonicity, qubit-cavity coupling, and detuning. A tunable-cavity frequency provides a way to strongly vary both the qubit-cavity detuning and coupling strength, which can reduce Purcell losses, cavity-induced dephasing of the qubit, and residual bus coupling for a system with multiple qubits. With our qubit-cavity system, we show that dynamic control over the cavity frequency enables one to avoid Purcell losses during coherent qubit evolutions and optimize state readout during qubit measurements. The maximum qubit decay time ${T}_{1}=1.5\phantom{\rule{0.222222em}{0ex}}\ensuremath{\mu}$s is found to be limited by surface dielectric losses from a design geometry similar to planar transmon qubits.

arXiv:1408.1760•Physical Review B•Jul 14, 2014•32 citations

Measurement and Quantum State Transfer in Superconducting Qubits

Eric Mlinar

The potential of superconducting qubits as the medium for a scalable quantum computer has motivated the pursuit of improved interactions within this system. Two challenges for the field of superconducting qubits are measurement fidelity, to accurately determine the state of the qubit, and the efficient transfer of quantum states. In measurement, the current state-of-the-art method employs dispersive readout, by coupling the qubit to a cavity and reading the resulting shift in cavity frequency to infer the qubit's state; however, this is vulnerable to Purcell relaxation, as well as being modeled off a simplified two-level abstraction of the qubit. In state transfer, the existing proposal for moving quantum states is mostly untested against non-idealities that will likely be present in an experiment. In this dissertation, we examine three problems within these two areas.We first describe a new scheme for fast and high-fidelity dispersive measurement specifically designed to circumvent the Purcell Effect. To do this, the qubit-resonator interaction is turned on only when the resonator is decoupled from the environment; then, after the resonator state has shifted enough to infer the qubit state, the qubit-resonator interaction is turned off before the resonator and environment are recoupled. We also show that the effectiveness of this ``Catch-Disperse-Release'' procedure partly originates from quadrature squeezing of the resonator state induced by the Jaynes-Cummings nonlinearity.The Catch-Disperse-Release measurement scheme treats the qubit as a two-level system, which is a common simplification used in theoretical works. However, the most promising physical candidate for a superconducting qubit, the transmon, is a multi-level system. In the second work, we examine the effects of including the higher energy levels of the transmon. Specifically, we expand the eigenstate picture developed in the first work to encompass multiple qubit levels, and examine the resulting changes to the system. In particular, we analyze the population of the non-target eigenstates as a result of this expanded model, and provide an analytical form for these deviations from the simpler model in Catch-Disperse-Release (i.e., the dressed state approximation).Lastly, we assess the robustness of the existing quantum state transfer protocol, testing its performance under typical experimental deviations from the ideal case. We show that the procedure is resilient to almost all non-idealities, except frequency mismatch between the two cavities. We also demonstrate a method to compensate for one such error in frequency-matching.

•Jan 1, 2016•0 citations

Sequential Dispersive Measurement of a Superconducting Qubit

Théau Peronnin, Danijela Marković, Quentin Ficheux +1 more

We present a superconducting device that realizes the sequential measurement of a transmon qubit. The device disables common limitations of dispersive readout such as Purcell effect or transients in the cavity mode by turning on and off the coupling to the measurement channel on demand. The qubit measurement begins by loading a readout resonator that is coupled to the qubit. After an optimal interaction time with negligible loss, a microwave pump releases the content of the readout mode by upconversion into a measurement line in a characteristic time as low as 10 ns, which is 400 times shorter than the lifetime of the readout resonator. A direct measurement of the released field quadratures demonstrates a readout fidelity of 97.5% in a total measurement time of 220 ns. The Wigner tomography of the readout mode allows us to characterize the non-Gaussian nature of the readout mode and its dynamics.

arXiv:1904.04635•Physical Review Letters•May 7, 2020•17 citations

Dynamics of Dispersive Measurements of Flux-Qubit States: Energy-Level Splitting Connected to Quantum Wave Mechanics

Jeong Ryeol Choi

Superconducting flux qubits have many advantages as a storage of quantum information, such as broad range tunability of frequency, small-size fabricability, and high controllability. In the flux qubit-oscillator, qubits are connected to SQUID resonators for the purpose of performing dispersive non-destructive readouts of qubit signals with high fidelity. In this work, we propose a theoretical model for analyzing quantum characteristics of a flux qubit-oscillator on the basis of quantum solutions obtained using a unitary transformation approach. The energy levels of the combined system (qubit + resonator) are analyzed in detail. Equally spaced each energy level of the resonator splits into two parts depending on qubit states. Besides, coupling of the qubit to the resonator brings about an additional modification in the split energy levels. So long as the coupling strength and the tunnel splitting are not zero but finite values, the energy-level splitting of the resonator does not disappear. We conclude that quantum nondemolition dispersive measurements of the qubit states are possible by inducing bifurcation of the resonator states through the coupling.

Nanomaterials•Aug 23, 2023•0 citations

Fast high-fidelity quantum nondemolition readout of a superconducting qubit with tunable transverse couplings

Bryan Gard, Zachary Parrott, Kurt A. Jacobs +2 more

Dispersive readout, the current standard for measuring superconducting qubits, relies on relatively easy to engineer, static transverse coupling between a qubit and a detuned cavity mode. However, this method requires circuit design trade-offs between qubit-cavity coupling, cavity-feedline coupling, detuning, and the resultant decoherence introduced by the cavity mode. Additionally, the criteria for performing quantum nondemolition measurements, including reduced cavity photon numbers, further limits speed and fidelity. In this work, we introduce a circuit with pulse-tunable qubit-cavity and cavity-feedline couplings so that the entire qubit-measurement process can be fully optimized. Here, the core measurement process resembles a quantum gate operation between the qubit and the cavity, with the cavity acting like an ancilla, storing the qubit-state information. To fully explore time-dependent effects of the full qubit-cavity dynamics, we go beyond the rotating-wave, Jaynes-Cummings, or dispersive approximations, to develop a pulsed-measurement protocol. In addition, we propose a realistic circuit architecture that can provide a very fast, high-fidelity, QND measurement with near-unit efficiency.

Physical Review Applied•Feb 5, 2024•8 citations

Sequential measurement of a superconducting qubit

Théau Peronnin, Danijela Marković, Quentin Ficheux +1 more

We present a superconducting device that realizes the sequential measurement of a transmon qubit. The unitary evolution between system and probe is indeed separated in time and space from the measurement of the probe itself. The device disables common limitations of dispersive readout such as Purcell effect or transients in the cavity mode by tuning the coupling to the measurement channel on demand. The probe is initially stored in a memory mode and coupled to the qubit until a microwave pump releases it into an output line in a characteristic time as low as $10~\mathrm{ns}$, which is 400 times shorter than the memory lifetime. The Wigner function of the memory allows us to characterize the non-Gaussian nature of the probe and its dynamics. A direct measurement of the released probe field quadratures demonstrates a readout fidelity of $97.5~\%$ in a total measurement time of $220~\mathrm{ns}$.

•Apr 9, 2019•2 citations
A metastable phase qubit was measured using a tunable cavity by two methods: a tunneling measurement followed by magnetometry readout by the cavity, and a non destructive dispersive measurement of the qubit by the cavity. The Purcell effect was observed as a decrease in the energy relaxation time of the qubit in the vicinity of the cavity, and could be manipulated by dynamically tuning the cavity. The observed dispersive shift of the cavity did not match the two-level system model for nonlinear qubits. Instead, a three-level model of the qubit was needed to describe the data, necessitated by the weakly nonlinear nature of the metastable phase qubit. The cavity was also used to directly observe the photons radiated by a tunneling measurement.
We describe a tunable-cavity quantum electrodynamics (QED) architecture with an rf SQUID phase qubit inductively coupled to a single-mode, resonant cavity with a tunable frequency that allows for both microwave readout of tunneling and dispersive measurements of the qubit. Dispersive measurement is well characterized by a three-level model, strongly dependent on qubit anharmonicity, qubit-cavity coupling, and detuning. A tunable-cavity frequency provides a way to strongly vary both the qubit-cavity detuning and coupling strength, which can reduce Purcell losses, cavity-induced dephasing of the qubit, and residual bus coupling for a system with multiple qubits. With our qubit-cavity system, we show that dynamic control over the cavity frequency enables one to avoid Purcell losses during coherent qubit evolutions and optimize state readout during qubit measurements. The maximum qubit decay time ${T}_{1}=1.5\phantom{\rule{0.222222em}{0ex}}\ensuremath{\mu}$s is found to be limited by surface dielectric losses from a design geometry similar to planar transmon qubits.
The potential of superconducting qubits as the medium for a scalable quantum computer has motivated the pursuit of improved interactions within this system. Two challenges for the field of superconducting qubits are measurement fidelity, to accurately determine the state of the qubit, and the efficient transfer of quantum states. In measurement, the current state-of-the-art method employs dispersive readout, by coupling the qubit to a cavity and reading the resulting shift in cavity frequency to infer the qubit's state; however, this is vulnerable to Purcell relaxation, as well as being modeled off a simplified two-level abstraction of the qubit. In state transfer, the existing proposal for moving quantum states is mostly untested against non-idealities that will likely be present in an experiment. In this dissertation, we examine three problems within these two areas.We first describe a new scheme for fast and high-fidelity dispersive measurement specifically designed to circumvent the Purcell Effect. To do this, the qubit-resonator interaction is turned on only when the resonator is decoupled from the environment; then, after the resonator state has shifted enough to infer the qubit state, the qubit-resonator interaction is turned off before the resonator and environment are recoupled. We also show that the effectiveness of this ``Catch-Disperse-Release'' procedure partly originates from quadrature squeezing of the resonator state induced by the Jaynes-Cummings nonlinearity.The Catch-Disperse-Release measurement scheme treats the qubit as a two-level system, which is a common simplification used in theoretical works. However, the most promising physical candidate for a superconducting qubit, the transmon, is a multi-level system. In the second work, we examine the effects of including the higher energy levels of the transmon. Specifically, we expand the eigenstate picture developed in the first work to encompass multiple qubit levels, and examine the resulting changes to the system. In particular, we analyze the population of the non-target eigenstates as a result of this expanded model, and provide an analytical form for these deviations from the simpler model in Catch-Disperse-Release (i.e., the dressed state approximation).Lastly, we assess the robustness of the existing quantum state transfer protocol, testing its performance under typical experimental deviations from the ideal case. We show that the procedure is resilient to almost all non-idealities, except frequency mismatch between the two cavities. We also demonstrate a method to compensate for one such error in frequency-matching.
We present a superconducting device that realizes the sequential measurement of a transmon qubit. The device disables common limitations of dispersive readout such as Purcell effect or transients in the cavity mode by turning on and off the coupling to the measurement channel on demand. The qubit measurement begins by loading a readout resonator that is coupled to the qubit. After an optimal interaction time with negligible loss, a microwave pump releases the content of the readout mode by upconversion into a measurement line in a characteristic time as low as 10 ns, which is 400 times shorter than the lifetime of the readout resonator. A direct measurement of the released field quadratures demonstrates a readout fidelity of 97.5% in a total measurement time of 220 ns. The Wigner tomography of the readout mode allows us to characterize the non-Gaussian nature of the readout mode and its dynamics.
Superconducting flux qubits have many advantages as a storage of quantum information, such as broad range tunability of frequency, small-size fabricability, and high controllability. In the flux qubit-oscillator, qubits are connected to SQUID resonators for the purpose of performing dispersive non-destructive readouts of qubit signals with high fidelity. In this work, we propose a theoretical model for analyzing quantum characteristics of a flux qubit-oscillator on the basis of quantum solutions obtained using a unitary transformation approach. The energy levels of the combined system (qubit + resonator) are analyzed in detail. Equally spaced each energy level of the resonator splits into two parts depending on qubit states. Besides, coupling of the qubit to the resonator brings about an additional modification in the split energy levels. So long as the coupling strength and the tunnel splitting are not zero but finite values, the energy-level splitting of the resonator does not disappear. We conclude that quantum nondemolition dispersive measurements of the qubit states are possible by inducing bifurcation of the resonator states through the coupling.
Dispersive readout, the current standard for measuring superconducting qubits, relies on relatively easy to engineer, static transverse coupling between a qubit and a detuned cavity mode. However, this method requires circuit design trade-offs between qubit-cavity coupling, cavity-feedline coupling, detuning, and the resultant decoherence introduced by the cavity mode. Additionally, the criteria for performing quantum nondemolition measurements, including reduced cavity photon numbers, further limits speed and fidelity. In this work, we introduce a circuit with pulse-tunable qubit-cavity and cavity-feedline couplings so that the entire qubit-measurement process can be fully optimized. Here, the core measurement process resembles a quantum gate operation between the qubit and the cavity, with the cavity acting like an ancilla, storing the qubit-state information. To fully explore time-dependent effects of the full qubit-cavity dynamics, we go beyond the rotating-wave, Jaynes-Cummings, or dispersive approximations, to develop a pulsed-measurement protocol. In addition, we propose a realistic circuit architecture that can provide a very fast, high-fidelity, QND measurement with near-unit efficiency.
We present a superconducting device that realizes the sequential measurement of a transmon qubit. The unitary evolution between system and probe is indeed separated in time and space from the measurement of the probe itself. The device disables common limitations of dispersive readout such as Purcell effect or transients in the cavity mode by tuning the coupling to the measurement channel on demand. The probe is initially stored in a memory mode and coupled to the qubit until a microwave pump releases it into an output line in a characteristic time as low as 10 ns10~\mathrm{ns}10 ns, which is 400 times shorter than the memory lifetime. The Wigner function of the memory allows us to characterize the non-Gaussian nature of the probe and its dynamics. A direct measurement of the released probe field quadratures demonstrates a readout fidelity of 97.5 %97.5~\%97.5 % in a total measurement time of 220 ns220~\mathrm{ns}220 ns.