Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Advanced texts in physics

Phase-Sensitive Amplification and Squeezing

H. A. Haus

Published Jan 1, 2000• 1 citation
Publisher
DOI
10.1007/978-3-662-04190-1_12

Related papers

Generation of Squeezed Light via Phase-Sensitive Amplification

Neil Corzo, Alberto M. Marino, Quentin C. Glorieux +2 more

Bulletin of the American Physical Society•Jun 17, 2011•0 citations

Improvement of Two-Mode Squeezing in the Presence of Loss with a Phase-Sensitive Amplifer

Li Tian, Brian Anderson, Bonnie L. Schmittberger +3 more

Bulletin of the American Physical Society•Jun 8, 2017•0 citations

Tolerance enhancement of inefficient detection and frequency detuning by non-perfect phase-sensitive amplification in broadband squeezing-based precision measurement

Changchang Zhang, Zhaolu Wang, Hongjun Liu +1 more

Phase-sensitive amplification (PSA) can significantly improve the degradation caused by inefficient detectors in squeezing-based precision measurements. However, broadband incident light will lead to non-perfect PSA. The present work focused on the enhancement of non-perfect PSA for squeezed states with broad bandwidth for the measurement of weak absorption detection. Numerical calculations of the quantum advantage show that non-perfect PSA can effectively improve the inefficiency of detection in slight drift frequency detuning.

Journal of the Optical Society of America B•Aug 24, 2022•3 citations

Phase sensitive amplification

Radan Slavı́k

•Aug 27, 2014•0 citations

Phase-sensitive amplification by the use of degenerate squeezed radiation

A. Jann, Y. Ben-Aryeh

We show that a phase-sensitive linear amplifier can be constructed based on pairs of identical two-level atoms, initially in their upper state. Correlations between the atoms are obtained in a high-Q cavity by their interaction with degenerate squeezed radiation. Such correlated pairs of atoms are injected into a linear amplifier, where phase-sensitive amplification is obtained with significant quantum noise reduction.

Journal of the Optical Society of America B•May 1, 1995•1 citation

Phase-sensitive amplification in a two-level system

Khalid Zaheer, Muhammad Suhail Zubairy

Optics Communications•Dec 1, 1988•20 citations
Phase-sensitive amplification (PSA) can significantly improve the degradation caused by inefficient detectors in squeezing-based precision measurements. However, broadband incident light will lead to non-perfect PSA. The present work focused on the enhancement of non-perfect PSA for squeezed states with broad bandwidth for the measurement of weak absorption detection. Numerical calculations of the quantum advantage show that non-perfect PSA can effectively improve the inefficiency of detection in slight drift frequency detuning.