Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Journal of Applied Physics

Influence of electric potentials on atom interferometers: Increased rotation sensitivity

Meriç Özcan

Published Jun 1, 1998• 2 citations
Publisher

Abstract

An atomic interferometer for rotation sensing is proposed. The arms of the interferometer are enclosed in a Faraday cage, and when a potential is applied to the cage, the resultant phase difference in the counterpropagating atom de Broglie waves due to rotation can be much larger than the Sagnac phase shift. This effect, being quantum mechanical in nature, could be used to increase the rotation sensitivity of atomic interferometers.

DOI
10.1063/1.367490

Related papers

High-sensitivity rotation sensing with atom interferometers using Aharonov-Bohm effect

Meri Özcan

In recent years there has been significant activity in research and development of high sensitivity accelerometers and gyroscopes using atom interferometers. In these devices, a fringe shift in the interference of atom de Broglie waves indicates the rotation rate of the interferometer relative to an inertial frame of reference. In both optical and atomic conventional Sagnac interferometers, the resultant phase difference due to rotation is independent of the wave velocity. However, we show that if an atom interforemeter is enclosed in a Faraday cage which is at some potential, the phase difference of the counter-propagating waves is proportional to the inverse square of the particle velocity and it is proportional to the applied potential. This is due to Aharonov-Bohm effect and it can be used to increase the rotation sensitivity of atom interferometers.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Feb 9, 2006•1 citation

Slow wave atom interferometers for rotation sensing

Meriç Özcan

A gyroscope based on Sagnac interferometer measures the rotation rate relative to an inertial frame of reference. Sagnac effect originally has been derived and experimentally demonstrated with optical waves. Later, matter wave based Sagnac interferometers were developed due to inherent sensitivity over a photon based system. However in any interferometer whether it is photon or matter wave based the resultant phase shift due to counter-rotating waves is independent of the wave velocity. Here we show that one can have a larger phase shift with slower matter waves using Aharonov-Bohm effect: the phase difference of the counter propagating waves is proportional to the inverse square of the particle velocity.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Feb 8, 2007•0 citations

Rotation Sensing with an Atom Interferometer

Alan Lenef, Troy D. Hammond, Edward T. Smith +3 more

We have measured the phase shift induced by rotation of an atom interferometer at rates of $\ensuremath{-}2$ to $+2$ earth rates and obtained $1%$ agreement with the predicted Sagnac phase shift for atomic matter waves. The rotational rms noise of our interferometer was $42$ milliearth rates for $1$ sec of integration time, within $9%$ of shot noise. The high sensitivity and agreement of predicted and measured behavior suggest useful future scientific applications of atom interferometers as inertial sensors.

Physical Review Letters•Feb 3, 1997•198 citations

Precision Rotation Sensing Using Atom Interferometry

T. L. Gustavson

A rotation-rate sensor was developed using atom interferometry and the Sagnac effect for matter waves. This device has a short-term sensitivity of 6× 10−10 rad/sec for a 1 second integration time, which is the best publicly reported value to date. It has high intrinsic accuracy because it relies on interactions between atoms and laser light that is stabilized to an atomic transition. Long-term stability is promising and characterization is currently underway. Potential applications include inertial navigation, geophysical studies, and general relativity tests such as verification of the Lense-Thirring and geodetic effects. The principle of operation is as follows: A thermal cesium atomic beam crosses three laser interaction regions where two-photon stimulated Raman transitions between cesium ground states transfer momentum to atoms and divide, deflect, and recombine the atomic wavepackets. Rotation induces a phase shift between the two possible trajectories and causes a change in the detected number of atoms with a particular internal state. Counterpropagating atomic beams form two interferometers using shared lasers for common-mode rejection, and the rotation phase shifts have opposite sign since the phase shift is proportional to the vector velocity of the atoms. Therefore, subtracting or adding the interferometer signals discriminates between rotation and transverse acceleration summed with laser arbitrary phase. Furthermore, in the inertial reference frame of the atoms, rotations Doppler-shift the Raman lasers. Adding Raman frequency shifts to cancel these Doppler-shifts allows operation at an effective zero rotation rate, improving sensitivity and bandwidth. Modulating these frequency shifts facilitates sensitive lock-in detection readout techniques.

•Jan 1, 2000•24 citations

Rotation sensing with a dual atom-interferometer Sagnac gyroscope

T. L. Gustavson, Arnaud Landragin, Mark A. Kasevich

We reports improvements to our Sagnac effect matter-wave interferometer gyroscope. This device now has a short-term rotation-rate sensitivity of 6 × 10 -10 rad s -1 over 1 s of integration, which is the best publicly reported value to date. Stimulated Raman transitions are used to coherently manipulate atoms from counterpropagating thermal beams, forming two interferometers with opposite rotation phase shifts, allowing rotation to be distinguished from acceleration and laser arbitrary phase. Furthermore, electronically compensating the rotation-induced Doppler shifts of the Raman lasers allows operation at an effective zero rotation rate, improving sensitivity and facilitating sensitive lock-in detection readout techniques. Long-term stability is promising but not yet fully characterized. Potential applications include inertial navigation, geophysical studies and tests of general relativity.

Classical and Quantum Gravity•Jun 8, 2000•474 citations

Atom Interferometer Gyroscope with Spin-Dependent Phase Shifts Induced by Light near a Tune-Out Wavelength

Raisa Trubko, James Greenberg, Michael T. St. Germaine +4 more

Tune-out wavelengths measured with an atom interferometer are sensitive to laboratory rotation rates because of the Sagnac effect, vector polarizability, and dispersion compensation. We observed shifts in measured tune-out wavelengths as large as 213 pm with a potassium atom beam interferometer, and we explore how these shifts can be used for an atom interferometer gyroscope.

arXiv:1510.06241•Physical Review Letters•Apr 9, 2015•31 citations
An atomic interferometer for rotation sensing is proposed. The arms of the interferometer are enclosed in a Faraday cage, and when a potential is applied to the cage, the resultant phase difference in the counterpropagating atom de Broglie waves due to rotation can be much larger than the Sagnac phase shift. This effect, being quantum mechanical in nature, could be used to increase the rotation sensitivity of atomic interferometers.
In recent years there has been significant activity in research and development of high sensitivity accelerometers and gyroscopes using atom interferometers. In these devices, a fringe shift in the interference of atom de Broglie waves indicates the rotation rate of the interferometer relative to an inertial frame of reference. In both optical and atomic conventional Sagnac interferometers, the resultant phase difference due to rotation is independent of the wave velocity. However, we show that if an atom interforemeter is enclosed in a Faraday cage which is at some potential, the phase difference of the counter-propagating waves is proportional to the inverse square of the particle velocity and it is proportional to the applied potential. This is due to Aharonov-Bohm effect and it can be used to increase the rotation sensitivity of atom interferometers.
A gyroscope based on Sagnac interferometer measures the rotation rate relative to an inertial frame of reference. Sagnac effect originally has been derived and experimentally demonstrated with optical waves. Later, matter wave based Sagnac interferometers were developed due to inherent sensitivity over a photon based system. However in any interferometer whether it is photon or matter wave based the resultant phase shift due to counter-rotating waves is independent of the wave velocity. Here we show that one can have a larger phase shift with slower matter waves using Aharonov-Bohm effect: the phase difference of the counter propagating waves is proportional to the inverse square of the particle velocity.
We have measured the phase shift induced by rotation of an atom interferometer at rates of $\ensuremath{-}2$ to +2+2+2 earth rates and obtained 11%1 agreement with the predicted Sagnac phase shift for atomic matter waves. The rotational rms noise of our interferometer was 424242 milliearth rates for 111 sec of integration time, within 99%9 of shot noise. The high sensitivity and agreement of predicted and measured behavior suggest useful future scientific applications of atom interferometers as inertial sensors.
A rotation-rate sensor was developed using atom interferometry and the Sagnac effect for matter waves. This device has a short-term sensitivity of 6× 10−10 rad/sec for a 1 second integration time, which is the best publicly reported value to date. It has high intrinsic accuracy because it relies on interactions between atoms and laser light that is stabilized to an atomic transition. Long-term stability is promising and characterization is currently underway. Potential applications include inertial navigation, geophysical studies, and general relativity tests such as verification of the Lense-Thirring and geodetic effects. The principle of operation is as follows: A thermal cesium atomic beam crosses three laser interaction regions where two-photon stimulated Raman transitions between cesium ground states transfer momentum to atoms and divide, deflect, and recombine the atomic wavepackets. Rotation induces a phase shift between the two possible trajectories and causes a change in the detected number of atoms with a particular internal state. Counterpropagating atomic beams form two interferometers using shared lasers for common-mode rejection, and the rotation phase shifts have opposite sign since the phase shift is proportional to the vector velocity of the atoms. Therefore, subtracting or adding the interferometer signals discriminates between rotation and transverse acceleration summed with laser arbitrary phase. Furthermore, in the inertial reference frame of the atoms, rotations Doppler-shift the Raman lasers. Adding Raman frequency shifts to cancel these Doppler-shifts allows operation at an effective zero rotation rate, improving sensitivity and bandwidth. Modulating these frequency shifts facilitates sensitive lock-in detection readout techniques.
We reports improvements to our Sagnac effect matter-wave interferometer gyroscope. This device now has a short-term rotation-rate sensitivity of 6 × 10 -10 rad s -1 over 1 s of integration, which is the best publicly reported value to date. Stimulated Raman transitions are used to coherently manipulate atoms from counterpropagating thermal beams, forming two interferometers with opposite rotation phase shifts, allowing rotation to be distinguished from acceleration and laser arbitrary phase. Furthermore, electronically compensating the rotation-induced Doppler shifts of the Raman lasers allows operation at an effective zero rotation rate, improving sensitivity and facilitating sensitive lock-in detection readout techniques. Long-term stability is promising but not yet fully characterized. Potential applications include inertial navigation, geophysical studies and tests of general relativity.