IEEE MTT-S International Microwave Symposium digest

NbN hot electron bolometric mixer with intrinsic receiver noise temperature of less than five times the quantum noise limit

Eyal Gerecht, Charles F. Musante, Yan Zhuang, M. Ji, K. S. Yngvesson, Thomas M. Goyette, Jerry Waldman A

Published Nov 7, 2002• 2 citations
Publisher

Abstract

In recent years, improvements in device development and quasi-optical coupling techniques utilizing planar antennas have led to a significant achievement in low noise receivers for the edges of the submillimeter frequency regime. Hot electron bolometric (HEB) receivers made of thin superconducting films such as NbN have produced a viable option for instruments designed to measure the molecular spectra for astronomical applications as well as in remote sensing of the atmosphere in the THz regime. This paper describes an NbN HEB mixer with intrinsic DSB receiver noise temperature of at most five times the quantum noise limit at frequencies as high as 2.24 THz.

DOI
10.1109/mwsym.2000.863527

Related papers

NbN Hot Electron Bolometric Mixers for a Quasi--Optical THz Receiver

M. Kroug

Experimental work on the development of a quasi-optical heterodyne receiver for the THz frequency range is reported. The mixing device is a superconducting hot electron bolometer (HEB) made from ultrathin, d = 3 - 5 nm, niobium nitride (NbN) films. Work described in this thesis comprises: The design of a prototype receiver using quasi-optical coupling. Device fabrication involving reactive magnetron sputtering of NbN films and lithographic definition of the antenna integrated mixer. An investigation of the receiver performance at frequencies between 0.6 THz and 2.5 THz. The best performance is obtained with HEB mixers made from NbN films with a thickness d = 3-3.5 nm and a critical temperature T c = 9 - 9.5 K. Double-side band receiver noise temperatures are 530 K at 0.6 THz, 650 K at 1.6 THz and 1100 K at 2.5 THz. Corrected for losses in the receiver input optics, these values amount to only 10 times the theoretical quantum limit. MgO as the substrate material has been shown to provide improved acoustic coupling between NbN film and the substrate compared to other materials such as Si or sapphire. A maximum IF gain bandwidth of 4.5 GHz has been measured under the same operating conditions which yield lowest noise temperature. The local oscilltor power requirement is ~250 nW absorbed in the bolometer. Quasi-optically coupled HEB mixers have become the device-of-choice for radio astronomical applications in the frequency regime at and above 1 THz.

•Jan 1, 2001•4 citations

New results for NbN phonon-cooled hot electron bolometric mixers above 1 THz

Eyal Gerecht, Charles F. Musante, H. Jian +7 more

NbN Hot Electron Bolometric (HEB) mixers have produced promising results in terms of DSB receiver noise temperature (2800 K at 1.56 THz). The LO source for these mixers is a gas laser pumped by a CO/sub 2/ laser and the device is quasi-optically coupled through an extended hemispherical lens and a self-complementary log-periodic toothed antenna. NbN HEBs do not require submicron dimensions, can be operated comfortably at 4.2 K or higher, and require LO power of about 100-500 nW. IF noise bandwidths of 5 GHz or greater have been demonstrated. The DC bias point is also not affected by thermal radiation at 300 K. Receiver noise temperatures below 1 THz are typically 450-600 K and are expected to gradually approach these levels above 1 THz as well. NbN HEB mixers thus are rapidly approaching the type of performance required of a rugged practical receiver for astronomy and remote sensing in the THz region.

IEEE Transactions on Applied Superconductivity•Jun 1, 1999•6 citations

Low Noise Receivers Using Niobium Nitride Hot Electron Bolometer Mixers from 0.76 to 3.1 THz

J. Chen, Min Liang, Lin Kang +5 more

Low noise receivers using quasi-optical superconducting niobium nitride (NbN) hot electron bolometer (HEB) mixers have been designed, fabricated and measured in the terahertz (THz) frequency range for THz applications in astronomy and cosmology. The NbN HEB mixers consist of a planar complementary antenna and several nanometer (nm) thick NbN bridge connecting across the antenna's inner terminals on high-resistivity Si substrates. A double sideband (DSB) receiver noise temperature of 664 K at 0.76 THz, 920 K at 1.6 THz, 1630 K at 2.5 THz and 1710 K at 3.1 THz has been obtained without corrections and no anti-reflection (AR) coating on the surface of the lens.

•Jan 1, 2009•1 citation

Performance of a quasi-optical NbN hot-electron bolometric mixer at terahertz frequencies

Yoshinori Uzawa, Shigehito Miki, Z Wang +4 more

The performance of a hot-electron bolometric (HEB) mixer based on NbN from 0.9 to 2.5 THz was investigated using a quasi-optical receiver configuration. An HEB mixer is an ultra-thin superconducting NbN strip located at the feed point of a thick normal conducting Au spiral antenna on a high-resistivity Si substrate. The active area of the mixer was 3 nm thick, 0.4 μm long and 4 μm wide. The quasi-optics consisted of an MgO hyperhemisphere with anti-reflection caps made of Kapton-JP polyimide film and an offset parabola to reduce input losses. The frequency dependence of the double-sideband receiver noise temperature was investigated at several frequencies by using a backward wave oscillator or an optically pumped far-infrared laser as the local oscillator. Results demonstrated low-noise and wide-band characteristics, below 1 K GHz −1 over the measured frequency range. At 917 GHz, the measured receiver noise temperature was 550 K across a 500 MHz intermediate-frequency bandwidth centred at 1.5 GHz, which is slightly better than that of other HEB mixers at around this frequency. This paper was presented at the 8th International Superconductive Electronics Conference, Osaka, Japan, 19–22 June 2001.

Superconductor Science and Technology•Dec 19, 2001•5 citations

NbN hot electron bolometric mixers at frequencies between 0.7 and 3.1 THz

Pavel A. Yagoubov, M. Kroug, Harald Merkel +3 more

The performance of NbN-based phonon-cooled hot electron bolometric (HEB) quasioptical mixers is investigated in the 0.7-3.1 THz frequency range. The devices are made from a 3.5-4 nm thick NbN film on high resistivity Si and integrated with a planar spiral antenna on the same substrate. The length of the bolometer microbridge is 0.1-0.2 µm; the width is 1-2 µm. The best results of the DSB receiver noise temperature measured at 1.5 GHz intermediate frequency are: 800 K at 0.7 THz, 1100 K at 1.6 THz, 2000 K at 2.5 THz and 4200 K at 3.1 THz. The measurements were performed with a far infrared laser as the local oscillator (LO) source. The estimated LO power requirement is less than 500 nW at the receiver input. First results on spiral antenna polarization measurements are reported.

Superconductor Science and Technology•Nov 1, 1999•13 citations

NbN phonon-cooled hot-electron bolometer as a mixer for THz heterodyne receivers

H.-W. Huebers, Josef Schubert, Alexei D. Semenov +4 more

We have investigated a phonon-cooled NbN hot electron bolometric (HEB) mixer in the frequency range from 0.7 THz to 5.2 THz. The device was a 3.5 nm thin film with an in- plane dimension of 1.7 X 0.2 micrometers 2 integrated in a complementary logarithmic spiral antenna. The measured DSB receiver noise temperatures are 1500 K, 2200 K, 2600 K, 2900 K, 4000 K, 5600 K and 8800 K. The sensitivity fluctuation, the long term stability, and the antenna pattern were measured and the suitability of the mixer for a practical heterodyne receiver is discussed.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Sep 9, 1999•2 citations
In recent years, improvements in device development and quasi-optical coupling techniques utilizing planar antennas have led to a significant achievement in low noise receivers for the edges of the submillimeter frequency regime. Hot electron bolometric (HEB) receivers made of thin superconducting films such as NbN have produced a viable option for instruments designed to measure the molecular spectra for astronomical applications as well as in remote sensing of the atmosphere in the THz regime. This paper describes an NbN HEB mixer with intrinsic DSB receiver noise temperature of at most five times the quantum noise limit at frequencies as high as 2.24 THz.
Experimental work on the development of a quasi-optical heterodyne receiver for the THz frequency range is reported. The mixing device is a superconducting hot electron bolometer (HEB) made from ultrathin, d = 3 - 5 nm, niobium nitride (NbN) films. Work described in this thesis comprises: The design of a prototype receiver using quasi-optical coupling. Device fabrication involving reactive magnetron sputtering of NbN films and lithographic definition of the antenna integrated mixer. An investigation of the receiver performance at frequencies between 0.6 THz and 2.5 THz. The best performance is obtained with HEB mixers made from NbN films with a thickness d = 3-3.5 nm and a critical temperature T c = 9 - 9.5 K. Double-side band receiver noise temperatures are 530 K at 0.6 THz, 650 K at 1.6 THz and 1100 K at 2.5 THz. Corrected for losses in the receiver input optics, these values amount to only 10 times the theoretical quantum limit. MgO as the substrate material has been shown to provide improved acoustic coupling between NbN film and the substrate compared to other materials such as Si or sapphire. A maximum IF gain bandwidth of 4.5 GHz has been measured under the same operating conditions which yield lowest noise temperature. The local oscilltor power requirement is ~250 nW absorbed in the bolometer. Quasi-optically coupled HEB mixers have become the device-of-choice for radio astronomical applications in the frequency regime at and above 1 THz.
NbN Hot Electron Bolometric (HEB) mixers have produced promising results in terms of DSB receiver noise temperature (2800 K at 1.56 THz). The LO source for these mixers is a gas laser pumped by a CO/sub 2/ laser and the device is quasi-optically coupled through an extended hemispherical lens and a self-complementary log-periodic toothed antenna. NbN HEBs do not require submicron dimensions, can be operated comfortably at 4.2 K or higher, and require LO power of about 100-500 nW. IF noise bandwidths of 5 GHz or greater have been demonstrated. The DC bias point is also not affected by thermal radiation at 300 K. Receiver noise temperatures below 1 THz are typically 450-600 K and are expected to gradually approach these levels above 1 THz as well. NbN HEB mixers thus are rapidly approaching the type of performance required of a rugged practical receiver for astronomy and remote sensing in the THz region.
Low noise receivers using quasi-optical superconducting niobium nitride (NbN) hot electron bolometer (HEB) mixers have been designed, fabricated and measured in the terahertz (THz) frequency range for THz applications in astronomy and cosmology. The NbN HEB mixers consist of a planar complementary antenna and several nanometer (nm) thick NbN bridge connecting across the antenna's inner terminals on high-resistivity Si substrates. A double sideband (DSB) receiver noise temperature of 664 K at 0.76 THz, 920 K at 1.6 THz, 1630 K at 2.5 THz and 1710 K at 3.1 THz has been obtained without corrections and no anti-reflection (AR) coating on the surface of the lens.
The performance of a hot-electron bolometric (HEB) mixer based on NbN from 0.9 to 2.5 THz was investigated using a quasi-optical receiver configuration. An HEB mixer is an ultra-thin superconducting NbN strip located at the feed point of a thick normal conducting Au spiral antenna on a high-resistivity Si substrate. The active area of the mixer was 3 nm thick, 0.4 μm long and 4 μm wide. The quasi-optics consisted of an MgO hyperhemisphere with anti-reflection caps made of Kapton-JP polyimide film and an offset parabola to reduce input losses. The frequency dependence of the double-sideband receiver noise temperature was investigated at several frequencies by using a backward wave oscillator or an optically pumped far-infrared laser as the local oscillator. Results demonstrated low-noise and wide-band characteristics, below 1 K GHz −1 over the measured frequency range. At 917 GHz, the measured receiver noise temperature was 550 K across a 500 MHz intermediate-frequency bandwidth centred at 1.5 GHz, which is slightly better than that of other HEB mixers at around this frequency. This paper was presented at the 8th International Superconductive Electronics Conference, Osaka, Japan, 19–22 June 2001.
The performance of NbN-based phonon-cooled hot electron bolometric (HEB) quasioptical mixers is investigated in the 0.7-3.1 THz frequency range. The devices are made from a 3.5-4 nm thick NbN film on high resistivity Si and integrated with a planar spiral antenna on the same substrate. The length of the bolometer microbridge is 0.1-0.2 µm; the width is 1-2 µm. The best results of the DSB receiver noise temperature measured at 1.5 GHz intermediate frequency are: 800 K at 0.7 THz, 1100 K at 1.6 THz, 2000 K at 2.5 THz and 4200 K at 3.1 THz. The measurements were performed with a far infrared laser as the local oscillator (LO) source. The estimated LO power requirement is less than 500 nW at the receiver input. First results on spiral antenna polarization measurements are reported.
We have investigated a phonon-cooled NbN hot electron bolometric (HEB) mixer in the frequency range from 0.7 THz to 5.2 THz. The device was a 3.5 nm thin film with an in- plane dimension of 1.7 X 0.2 micrometers 2 integrated in a complementary logarithmic spiral antenna. The measured DSB receiver noise temperatures are 1500 K, 2200 K, 2600 K, 2900 K, 4000 K, 5600 K and 8800 K. The sensitivity fluctuation, the long term stability, and the antenna pattern were measured and the suitability of the mixer for a practical heterodyne receiver is discussed.