Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment

A large-area neutron-interferometer optimized for coherent beam deflection: Applications

J. Springer, Michael Zawisky, R. Farthofer, Hartmut Lemmel, M. Suda, U. Kuetgens

Published Feb 9, 2010• 5 citations
Publisher
DOI
10.1016/j.nima.2010.01.080

Related papers

Fundamental and applied neutron interferometry

Johann Summhammer, Anton Zeilinger

Physica B Condensed Matter•Oct 1, 1991•4 citations

Neutron interferometers and apparatus

Helmut Rauch, Samuel A. Werner

Among the various areas of neutron optical research, neutron interferometry has provided some of the most challenging and spectacular developments. In most cases, separated coherent beams are used which are produced either by wavefront division (Young’s type) or by amplitude division (Mach− Zehnder type). These beams are subsequently coherently superposed after passing through regions of space where the neutron wavefunction is modified in phase and amplitude by various interactions: nuclear, magnetic, electromagnetic, gravitational, or by geometry and topology (as in Aharonov−Bohm-type experiments). Various types of neutron interferometers that have been tested are shown in Fig. 2.1. The first neutron interferometer was based upon wavefront division and biprism deflection, but it had several constraints for interferometric applications mainly due to the small beam separation (100 μm) (Maier-Leibnitz and Springer 1962). Nevertheless, this method gained further interest for diffraction experiments from macroscopic objects and for the detection of weak interaction effects where the long flight paths (10 m) enhance the sensitivity for the measurements of these effects (Gähler et al. 1980; Klein et al. 1981a). The perfect-crystal interferometer (Rauch et al. 1974) provides widely separated coherent beams and has become a standard method for advanced neutron optical investigations. The development of diffraction and phase grating interferometers extended the Mach-Zehnder interferometer method to very slow neutrons (loffe et al. 1985; Gruber et al. 1989). The superposition of spin-up and spin-down states in the longitudinal direction provides the basis for Larmor and Ramsey interferometry, where no lateral beam splitting is necessary. The well-known spin-echo systems (Mezei 1972) and zero-field spin-echo systems (Gähler and Golub 1987; Dubbers et al. 1989) are examples of such interferometers, which also play an important role in atom interferometry (Bord é 1989; Kasevich and Chu 1991; Riehle et al. 1991).

Oxford University Press eBooks•Aug 10, 2000•0 citations

Self-alignment of a compact large-area atomic Sagnac interferometer

Gunnar Tackmann, Peter Berg, Christian Schubert +4 more

We report on the realization of a compact atomic Mach–Zehnder-type Sagnac interferometer of 13.7 cm length, which covers an area of 19 mm 2 previously reported only for large thermal beam interferometers. According to Sagnac's formula, which holds for both light and atoms, the sensitivity for rotation rates increases linearly with the area enclosed by the interferometer. The use of cold atoms instead of thermal atoms enables miniaturization of Sagnac interferometers without sacrificing large areas. In comparison with thermal beams, slow atoms offer better matching of the initial beam velocity and the velocity with which the matter waves separate. In our case, the area is spanned by a cold atomic beam of 2.79 m s −1 , which is split, deflected and combined by driving a Raman transition between the two hyperfine ground states of 87 Rb in three spatially separated light zones. The use of cold atoms requires a precise angular alignment and high wave front quality of the three independent light zones over the cloud envelope. We present a procedure for mutually aligning the beam splitters at the microradian level by making use of the atom interferometer itself in different configurations. With this method, we currently achieve a sensitivity of .

New Journal of Physics•Jan 20, 2012•115 citations

Neutron resonators and interferometers for very low energy neutrons

A. Steyerl, Winfried Drexel, S. S. Malik +1 more

Physica B+C•Jul 1, 1988•41 citations

JAMIN-TYPE INTERFEROMETER FOR COLD NEUTRONS USING ETALON PLATES

Masaaki Kitaguchi, H. Funahashi, Masahiro Hino

The authors have proposed and tested a new type of multilayer cold-neutron interferometer based on a pair of etalons. The range of experimental application of conventional multilayer cold-neutron interferometer was limited due to the small spatial separation between the two coherent beams. Using etalons with an air gap of 20μm in spacing we have observed interference fringes with the contrast of (3.5 ± 0.7)%. The present results have demonstrated the feasibility of developing a cold neutron interferometer with a large path separation to carry out high precision measurements and new types of experiment.

Foundations of Quantum Mechanics in the Light of New Technology•Oct 1, 2002•0 citations

Achievements in neutron interferometry

H. Rauch

Acta physica Hungarica•Dec 1, 1994•1 citation
Among the various areas of neutron optical research, neutron interferometry has provided some of the most challenging and spectacular developments. In most cases, separated coherent beams are used which are produced either by wavefront division (Young’s type) or by amplitude division (Mach− Zehnder type). These beams are subsequently coherently superposed after passing through regions of space where the neutron wavefunction is modified in phase and amplitude by various interactions: nuclear, magnetic, electromagnetic, gravitational, or by geometry and topology (as in Aharonov−Bohm-type experiments). Various types of neutron interferometers that have been tested are shown in Fig. 2.1. The first neutron interferometer was based upon wavefront division and biprism deflection, but it had several constraints for interferometric applications mainly due to the small beam separation (100 μm) (Maier-Leibnitz and Springer 1962). Nevertheless, this method gained further interest for diffraction experiments from macroscopic objects and for the detection of weak interaction effects where the long flight paths (10 m) enhance the sensitivity for the measurements of these effects (Gähler et al. 1980; Klein et al. 1981a). The perfect-crystal interferometer (Rauch et al. 1974) provides widely separated coherent beams and has become a standard method for advanced neutron optical investigations. The development of diffraction and phase grating interferometers extended the Mach-Zehnder interferometer method to very slow neutrons (loffe et al. 1985; Gruber et al. 1989). The superposition of spin-up and spin-down states in the longitudinal direction provides the basis for Larmor and Ramsey interferometry, where no lateral beam splitting is necessary. The well-known spin-echo systems (Mezei 1972) and zero-field spin-echo systems (Gähler and Golub 1987; Dubbers et al. 1989) are examples of such interferometers, which also play an important role in atom interferometry (Bord é 1989; Kasevich and Chu 1991; Riehle et al. 1991).
We report on the realization of a compact atomic Mach–Zehnder-type Sagnac interferometer of 13.7 cm length, which covers an area of 19 mm 2 previously reported only for large thermal beam interferometers. According to Sagnac's formula, which holds for both light and atoms, the sensitivity for rotation rates increases linearly with the area enclosed by the interferometer. The use of cold atoms instead of thermal atoms enables miniaturization of Sagnac interferometers without sacrificing large areas. In comparison with thermal beams, slow atoms offer better matching of the initial beam velocity and the velocity with which the matter waves separate. In our case, the area is spanned by a cold atomic beam of 2.79 m s −1 , which is split, deflected and combined by driving a Raman transition between the two hyperfine ground states of 87 Rb in three spatially separated light zones. The use of cold atoms requires a precise angular alignment and high wave front quality of the three independent light zones over the cloud envelope. We present a procedure for mutually aligning the beam splitters at the microradian level by making use of the atom interferometer itself in different configurations. With this method, we currently achieve a sensitivity of .
The authors have proposed and tested a new type of multilayer cold-neutron interferometer based on a pair of etalons. The range of experimental application of conventional multilayer cold-neutron interferometer was limited due to the small spatial separation between the two coherent beams. Using etalons with an air gap of 20μm in spacing we have observed interference fringes with the contrast of (3.5 ± 0.7)%. The present results have demonstrated the feasibility of developing a cold neutron interferometer with a large path separation to carry out high precision measurements and new types of experiment.