Superconductor Science and Technology

From micro- to nano-SQUIDs: applications to nanomagnetism

Wolfgang Wernsdorfer

Published May 14, 2009• 246 citations
Publisher

Abstract

Due to a growing interest in quantum information processing based on spin systems, the micro-SQUID technique has been finding new interest and fabrication improvements have led to nano-SQUIDs. There are two types of nano-SQUIDs: either the cross section of the Josephson junctions is reduced to about 1 nm by using carbon nanotube junctions, or the loop size is reduced to a few 100 nm. This paper reviews the basic ideas of the micro-SQUID technique applied to magnetic nanostructures and shows that both types of nano-SQUIDs lead to a significant improvement concerning the detection of magnetization switching of individual magnetic particles or molecules.

DOI
10.1088/0953-2048/22/6/064013

Related papers

Applications of superconducting electronics to quantum optics and quantum metrology

Ling Yun Hao

SQUIDs (superconducting quantum interference devices) have been in use for more than half a century and constitute one of the first macroscopic quantum devices. SQUIDs operating at millikelvin temperatures can act as qubits for quantum computers and the recent reports of more than 50 qubit circuits indicate how far the technology has developed. In this talk, the author will describe two other applications of SQUIDs as quantum detectors, focusing on single spin and single photon energy resolving detection. Most superconducting devices rely on tri-layer Josephson tunnel junctions which are not easily scalable to the nanoscale. We have developed a Josephson junction fabrication method, based on electron beam lithography or focused ion beam milling of a single thin film of superconductor (Nb generally) which can provide sizes down to 50 nm. These devices are particularly relevant for two main applications in quantum technology and metrology. First, by shrinking the size of the SQUID loop and the junctions to around 200 nm, the sensitivity of the SQUID for magnetization measurements is improved to the level where a single electron spin flip may be detected. This is possible at the relatively elevated temperature of 4K.  We are working with Surrey University to implant single magnetic ions within the SQUID loop to provide a platform to test this combination as the basis for a new form of qubit operating at higher temperatures than the conventional Transmon superconducting devices. A second SQUID based detector which we are developing is an inductive transition edge sensor device (ISTED) for energy resolving measurements of single photons. This is based on the development of conventional transition edge sensors where we detect the change of the penetration depth of a small thin film of superconductor when it absorbs a photon. In this way, a major source of noise in conventional TES may be avoided since the absorber remains in the superconducting state at all times. In this way we have demonstrated single photon detection at 633 nm with 0.1eV resolution at operating temperature of 7.5K.

Advances in Automobile Engineering•Jan 1, 2021•0 citations

Performance of nano superconducting quantum interference devices for small spin cluster detection

C. Granata, Antonio Vettoliere, Pravin S. Walke +2 more

In the present paper, performance of nano-superconducting-quantum-interference devices (SQUIDs) has been investigated in view of their employment in the detection of small spin populations. The analysis has been focused on nano-SQUID sensors having a square loop with a side length of 200 nm. We calculate the spin sensitivity and the magnetic response relative to the single Bohr magneton (single spin), as a function of its position within the SQUID hole. The results show that the SQUID response depends strongly on the spin position; the ratio between the spin sensitivity evaluated in the center of the loop and the minimum one is as high as a factor of 3 for a spin at a reasonable distance z′ of 10 nm from the SQUID plane. Furthermore, the magnetic flux due to several hundred of spins has been evaluated by considering different random spin distributions within the SQUID hole. Due to the both nonuniform SQUID response and the random distribution process, the results show a statistical uncertainty which has been evaluated as a function of the spin number. The estimated informations are very useful to optimize the sensor performance in view of the most nanomagnetism applications.

Journal of Applied Physics•Jul 15, 2009•26 citations

Measurement of the spatial sensitivity of miniature SQUIDs using magnetic-tipped STM

Patrick Josephs-Franks, L Hao, Alexander Ya. Tzalenchuk +5 more

Large area superconducting quantum interference devices (SQUIDs) are known to be ultimate sensors of magnetic flux. By diminishing the size of a SQUID loop, the energy sensitivity of the device can be increased to near quantum-limited operation whilst also making it less sensitive to external magnetic field noise and improving its coupling to any nano-scale magnetic particle within the loop. This makes it an ideal nano-sensor for magnetic particles including single molecules. It is, however, important to optimize the coupling between any magnetic nano-particle placed within the SQUID and the SQUID itself in order to achieve maximum sensitivity for the spin detection. We have made some preliminary calculations of the expected SQUID response to a magnetic particle placed at different locations within the SQUID device, and using a magnetic tip in a scanning tunnelling microscope (STM) we are able to produce a spatial map of the SQUID sensitivity. Initial results on a 3 µm diameter loop SQUID are presented to demonstrate this method.

Superconductor Science and Technology•Nov 13, 2003•23 citations

Investigation of all niobium nano-SQUIDs based on sub-micrometer cross-type Josephson junctions

Matthias Schmelz, Y Matsui, Ronny Stolz +6 more

We report on the development of highly sensitive SQUIDs featuring sub-micrometer loop dimensions. The integration of high quality and low capacitance SIS Nb/AlO x /Nb cross-type Josephson tunnel junctions results in white flux noise levels as low as 66 n Φ 0 Hz −1/2 , well below state-of-the-art values of their Nb-based counterparts based on constriction type junctions. Estimation of the spin sensitivity of the best SQUIDs yield S μ 1/2 < 7 μ B Hz −1/2 in the white noise region, suitable for the investigation of small spin systems. We discuss fabrication challenges, show results on the electrical characterization of devices with various pickup loops, and describe options for further improvement, which may push the sensitivity of such devices even to single spin resolution.

arXiv:1501.00958•Superconductor Science and Technology•Nov 26, 2014•27 citations

A micro-SQUID with dispersive readout for magnetic scanning microscopy

Foroughi, F., Mol, J.-M., T. Müller +3 more

We have designed and characterized a micro-SQUID with dispersive readout for use in low temperature scanning probe microscopy systems. The design features a capacitively shunted RF SQUID with a tunable resonance frequency from 5 to 12 GHz, micrometer spatial resolution, and integrated superconducting coils for local application of magnetic fields. The SQUID is operated as a nonlinear oscillator with a flux- and power-dependent resonance frequency. Measurements for device characterization and noise benchmarking were carried out at 4 K. The measured flux noise above 10 kHz at 4 K is 80 nΦ0 Hz−1∕2 at a bandwidth of 200 MHz. Estimations suggest that one can benefit from parametric gain based on inherent nonlinearity of the Josephson junction and reduce the flux noise to 30 nΦ0Hz–1∕2 at 100 mK, which corresponds to 10.6 μBHz–1∕2 for a magnetic moment located at the center of the pickup loop.Measuring the magnetic response of mesoscopic samples or mapping it vs. position for extended systems is effective methods for revealing the fundamental quantum properties of condensed matter systems. Over the past few decades, many advanced magnetic imaging schemes have been developed, including magnetic force microscopy,1 scanning Hall probe microscopy,2 superconducting interference devices (SQUIDs),3,4 and NV center based magnetometry.5 The high sensitivity, low back action, and low power dissipation of SQUIDs make them attractive for many types of low temperature experiments. One classic example is the central role of scanning SQUID microscopy in tests of pairing symmetry of high-Tc cuprate superconductors.6 Other prominent applications are the thermodynamic characteristics of persistent currents in normal metal rings7 and proof of edge states in topological insulators in the quantum spin Hall regime.8A key performance for a SQUID is its flux sensitivity. Parametric amplification has been harnessed in nano-SQUIDs based on aluminum junctions9,10 in order to reduce the flux noise down to 30 nΦ0Hz–1∕2 with a bandwidth exceeding 60 MHz.10 Recent studies on parametric amplifiers and dispersive readout of superconducting qubits also harness the nonlinearity of the Josephson junction to boost sensitivity.11–13In scanning SQUID microscopy, signal sources often behave dipole-like, such as superconducting vortices in mesoscopic dots or currents in mesoscopic rings. Smaller SQUIDs provide better coupling to smaller samples which leads to higher spin sensitivity3,14 as the magnetic field of a dipole decreases with 1/r3. Various approaches have been pursued to reduce the size. The smallest nano-SQUID to date has been fabricated by evaporating Nb or Pb15 onto the apex of a sharp quartz tip reaching a loop diameter of below nm and a spin sensitivity of 0.38 μBHz−1/2 at tens of kHz bandwidth. Compared to such size-optimized devices, micro-SQUIDs fabricated using a standard Nb technique have the advantage of on-chip field coils and modulation coils,14 and can be operated at 4 K allowing for a wide range of applications. However, these come at the cost of larger pick-up loops of a few microns and a resulting poorer spin sensitivity of 200 μBHz−1/2 for a magnetic moment located at the center of the pickup loop.The limitation of large pickup loops was previously only overcome by devices with pickup loops defined by the focused-ion-beam,16 but has recently also been achieved by improvements in lithography and shown to offer better spatial resolution as well.17 Here, we present a scanning micro-SQUID which is based on the same fabrication technology incorporating another major advancement. Our design exploits the parametric amplification based on nonlinearities of the SQUID to boost sensitivity. The combination of a smaller pickup loop and parametric amplification of the signal leads to better spin sensitivity (10.6 μBHz−1/2) and higher bandwidth (200 MHz) compared to traditional DC micro-SQUIDs in which the flux sensitivity is mainly limited by internal dissipation.Our devices were fabricated at Hypres Inc. using planarized Nb/AlOx/Nb trilayer Josephson junction technology, including two planarized Nb layers with approximately 0.8 μm minimum feature size. The SQUID consists of a superconducting ring shunted by one Josephson junction with a designed critical current of 20 μA [Fig. 1(a)]. With this geometry, the SQUID is gradiometric, i.e., the effect of any homogeneous background magnetic field approximately cancels out. The smallest pickup loops implemented have an inner (outer) diameter of 1 μm (2 μm). The superconducting loop is shunted by an on-chip parallel-plate capacitor with amorphous silicon dioxide as dielectric which was designed to have a capacitance of 80 pF. The superconducting loop and the capacitor form a resonator with a flux dependent resonance frequency from 5 to 12 GHz. The pickup loops are placed on opposite corners of the parallel-plate capacitor at a distance of about 450 μm so that one loop can be located in close proximity to the sample while the other is kept far away from it. External fields can be applied to the sample by local single-turn field coils situated around each pickup loop. The field coils are fully integrated into the chip layout and can also be used to bias the SQUID at its most sensitive point. Compared to using additional modulation coils,14 this approach has the advantage of reducing the total device inductance, which leads to a higher sensitivity.18 In a scanning microscope, the field coil at the rear end (away from the sample) can be used to bias the SQUID or operate it in flux feedback such that resulting stray fields will not act on the sample, apart from a weak screening current through the pickup loop. The effective diameter of each coil is 7.5 μm, resulting in a mutual inductance of about 0.34 Φ0/mA (for the smallest pickup loop). The SQUID resonator is connected by an on-chip Z0 = 50 Ω coplanar waveguide (CPW) transmission line to the bonding pads. The two field coils are connected by two smaller CPWs to the bottom edge bonding pads [Fig. 1(c)], ending in two parallel-stripline waveguides running alongside the edges of the capacitor towards the respective field coils. Based on estimations, it should thus be possible to apply high frequency signals of at least several GHz to SQUID and sample.

•Jan 1, 2018•14 citations

Superconducting Nanodevices

J.C. Gallop, L. Hao

This article reviews recent progress in superconducting nanodevices, with particular emphasis on fabrication methods developed for superconducting nanowires and nanoscale Josephson junctions based on different barrier materials. It evaluates the future potential of superconducting nanodevices, including nano-superconducting quantum interference devices (nanoSQUIDs), in light of improvements in nanoscale fabrication and manipulation techniques, along with their likely impacts on future quantum technology and measurement. The article first considers efforts to realize devices at the physical scale of 100 nm and below before discussing different types of Josephson junction such as trilayer junctions. It also describes the use of focused ion beam milling and electron beam lithography techniques for junction fabrication at the nanoscale and the improved energy sensitivity detectable with a nanoSQUID. Finally, it looks at a range of applications for nanoSQUIDs, superconducting single photon detectors, and other superconducting nanodevices.

Oxford University Press eBooks•Jul 6, 2017•0 citations
Due to a growing interest in quantum information processing based on spin systems, the micro-SQUID technique has been finding new interest and fabrication improvements have led to nano-SQUIDs. There are two types of nano-SQUIDs: either the cross section of the Josephson junctions is reduced to about 1 nm by using carbon nanotube junctions, or the loop size is reduced to a few 100 nm. This paper reviews the basic ideas of the micro-SQUID technique applied to magnetic nanostructures and shows that both types of nano-SQUIDs lead to a significant improvement concerning the detection of magnetization switching of individual magnetic particles or molecules.
SQUIDs (superconducting quantum interference devices) have been in use for more than half a century and constitute one of the first macroscopic quantum devices. SQUIDs operating at millikelvin temperatures can act as qubits for quantum computers and the recent reports of more than 50 qubit circuits indicate how far the technology has developed. In this talk, the author will describe two other applications of SQUIDs as quantum detectors, focusing on single spin and single photon energy resolving detection. Most superconducting devices rely on tri-layer Josephson tunnel junctions which are not easily scalable to the nanoscale. We have developed a Josephson junction fabrication method, based on electron beam lithography or focused ion beam milling of a single thin film of superconductor (Nb generally) which can provide sizes down to 50 nm. These devices are particularly relevant for two main applications in quantum technology and metrology. First, by shrinking the size of the SQUID loop and the junctions to around 200 nm, the sensitivity of the SQUID for magnetization measurements is improved to the level where a single electron spin flip may be detected. This is possible at the relatively elevated temperature of 4K.  We are working with Surrey University to implant single magnetic ions within the SQUID loop to provide a platform to test this combination as the basis for a new form of qubit operating at higher temperatures than the conventional Transmon superconducting devices. A second SQUID based detector which we are developing is an inductive transition edge sensor device (ISTED) for energy resolving measurements of single photons. This is based on the development of conventional transition edge sensors where we detect the change of the penetration depth of a small thin film of superconductor when it absorbs a photon. In this way, a major source of noise in conventional TES may be avoided since the absorber remains in the superconducting state at all times. In this way we have demonstrated single photon detection at 633 nm with 0.1eV resolution at operating temperature of 7.5K.
In the present paper, performance of nano-superconducting-quantum-interference devices (SQUIDs) has been investigated in view of their employment in the detection of small spin populations. The analysis has been focused on nano-SQUID sensors having a square loop with a side length of 200 nm. We calculate the spin sensitivity and the magnetic response relative to the single Bohr magneton (single spin), as a function of its position within the SQUID hole. The results show that the SQUID response depends strongly on the spin position; the ratio between the spin sensitivity evaluated in the center of the loop and the minimum one is as high as a factor of 3 for a spin at a reasonable distance z′ of 10 nm from the SQUID plane. Furthermore, the magnetic flux due to several hundred of spins has been evaluated by considering different random spin distributions within the SQUID hole. Due to the both nonuniform SQUID response and the random distribution process, the results show a statistical uncertainty which has been evaluated as a function of the spin number. The estimated informations are very useful to optimize the sensor performance in view of the most nanomagnetism applications.
Large area superconducting quantum interference devices (SQUIDs) are known to be ultimate sensors of magnetic flux. By diminishing the size of a SQUID loop, the energy sensitivity of the device can be increased to near quantum-limited operation whilst also making it less sensitive to external magnetic field noise and improving its coupling to any nano-scale magnetic particle within the loop. This makes it an ideal nano-sensor for magnetic particles including single molecules. It is, however, important to optimize the coupling between any magnetic nano-particle placed within the SQUID and the SQUID itself in order to achieve maximum sensitivity for the spin detection. We have made some preliminary calculations of the expected SQUID response to a magnetic particle placed at different locations within the SQUID device, and using a magnetic tip in a scanning tunnelling microscope (STM) we are able to produce a spatial map of the SQUID sensitivity. Initial results on a 3 µm diameter loop SQUID are presented to demonstrate this method.
We report on the development of highly sensitive SQUIDs featuring sub-micrometer loop dimensions. The integration of high quality and low capacitance SIS Nb/AlO x /Nb cross-type Josephson tunnel junctions results in white flux noise levels as low as 66 n Φ 0 Hz −1/2 , well below state-of-the-art values of their Nb-based counterparts based on constriction type junctions. Estimation of the spin sensitivity of the best SQUIDs yield S μ 1/2 < 7 μ B Hz −1/2 in the white noise region, suitable for the investigation of small spin systems. We discuss fabrication challenges, show results on the electrical characterization of devices with various pickup loops, and describe options for further improvement, which may push the sensitivity of such devices even to single spin resolution.
We have designed and characterized a micro-SQUID with dispersive readout for use in low temperature scanning probe microscopy systems. The design features a capacitively shunted RF SQUID with a tunable resonance frequency from 5 to 12 GHz, micrometer spatial resolution, and integrated superconducting coils for local application of magnetic fields. The SQUID is operated as a nonlinear oscillator with a flux- and power-dependent resonance frequency. Measurements for device characterization and noise benchmarking were carried out at 4 K. The measured flux noise above 10 kHz at 4 K is 80 nΦ0 Hz−1∕2 at a bandwidth of 200 MHz. Estimations suggest that one can benefit from parametric gain based on inherent nonlinearity of the Josephson junction and reduce the flux noise to 30 nΦ0Hz–1∕2 at 100 mK, which corresponds to 10.6 μBHz–1∕2 for a magnetic moment located at the center of the pickup loop.Measuring the magnetic response of mesoscopic samples or mapping it vs. position for extended systems is effective methods for revealing the fundamental quantum properties of condensed matter systems. Over the past few decades, many advanced magnetic imaging schemes have been developed, including magnetic force microscopy,1 scanning Hall probe microscopy,2 superconducting interference devices (SQUIDs),3,4 and NV center based magnetometry.5 The high sensitivity, low back action, and low power dissipation of SQUIDs make them attractive for many types of low temperature experiments. One classic example is the central role of scanning SQUID microscopy in tests of pairing symmetry of high-Tc cuprate superconductors.6 Other prominent applications are the thermodynamic characteristics of persistent currents in normal metal rings7 and proof of edge states in topological insulators in the quantum spin Hall regime.8A key performance for a SQUID is its flux sensitivity. Parametric amplification has been harnessed in nano-SQUIDs based on aluminum junctions9,10 in order to reduce the flux noise down to 30 nΦ0Hz–1∕2 with a bandwidth exceeding 60 MHz.10 Recent studies on parametric amplifiers and dispersive readout of superconducting qubits also harness the nonlinearity of the Josephson junction to boost sensitivity.11–13In scanning SQUID microscopy, signal sources often behave dipole-like, such as superconducting vortices in mesoscopic dots or currents in mesoscopic rings. Smaller SQUIDs provide better coupling to smaller samples which leads to higher spin sensitivity3,14 as the magnetic field of a dipole decreases with 1/r3. Various approaches have been pursued to reduce the size. The smallest nano-SQUID to date has been fabricated by evaporating Nb or Pb15 onto the apex of a sharp quartz tip reaching a loop diameter of below nm and a spin sensitivity of 0.38 μBHz−1/2 at tens of kHz bandwidth. Compared to such size-optimized devices, micro-SQUIDs fabricated using a standard Nb technique have the advantage of on-chip field coils and modulation coils,14 and can be operated at 4 K allowing for a wide range of applications. However, these come at the cost of larger pick-up loops of a few microns and a resulting poorer spin sensitivity of 200 μBHz−1/2 for a magnetic moment located at the center of the pickup loop.The limitation of large pickup loops was previously only overcome by devices with pickup loops defined by the focused-ion-beam,16 but has recently also been achieved by improvements in lithography and shown to offer better spatial resolution as well.17 Here, we present a scanning micro-SQUID which is based on the same fabrication technology incorporating another major advancement. Our design exploits the parametric amplification based on nonlinearities of the SQUID to boost sensitivity. The combination of a smaller pickup loop and parametric amplification of the signal leads to better spin sensitivity (10.6 μBHz−1/2) and higher bandwidth (200 MHz) compared to traditional DC micro-SQUIDs in which the flux sensitivity is mainly limited by internal dissipation.Our devices were fabricated at Hypres Inc. using planarized Nb/AlOx/Nb trilayer Josephson junction technology, including two planarized Nb layers with approximately 0.8 μm minimum feature size. The SQUID consists of a superconducting ring shunted by one Josephson junction with a designed critical current of 20 μA [Fig. 1(a)]. With this geometry, the SQUID is gradiometric, i.e., the effect of any homogeneous background magnetic field approximately cancels out. The smallest pickup loops implemented have an inner (outer) diameter of 1 μm (2 μm). The superconducting loop is shunted by an on-chip parallel-plate capacitor with amorphous silicon dioxide as dielectric which was designed to have a capacitance of 80 pF. The superconducting loop and the capacitor form a resonator with a flux dependent resonance frequency from 5 to 12 GHz. The pickup loops are placed on opposite corners of the parallel-plate capacitor at a distance of about 450 μm so that one loop can be located in close proximity to the sample while the other is kept far away from it. External fields can be applied to the sample by local single-turn field coils situated around each pickup loop. The field coils are fully integrated into the chip layout and can also be used to bias the SQUID at its most sensitive point. Compared to using additional modulation coils,14 this approach has the advantage of reducing the total device inductance, which leads to a higher sensitivity.18 In a scanning microscope, the field coil at the rear end (away from the sample) can be used to bias the SQUID or operate it in flux feedback such that resulting stray fields will not act on the sample, apart from a weak screening current through the pickup loop. The effective diameter of each coil is 7.5 μm, resulting in a mutual inductance of about 0.34 Φ0/mA (for the smallest pickup loop). The SQUID resonator is connected by an on-chip Z0 = 50 Ω coplanar waveguide (CPW) transmission line to the bonding pads. The two field coils are connected by two smaller CPWs to the bottom edge bonding pads [Fig. 1(c)], ending in two parallel-stripline waveguides running alongside the edges of the capacitor towards the respective field coils. Based on estimations, it should thus be possible to apply high frequency signals of at least several GHz to SQUID and sample.
This article reviews recent progress in superconducting nanodevices, with particular emphasis on fabrication methods developed for superconducting nanowires and nanoscale Josephson junctions based on different barrier materials. It evaluates the future potential of superconducting nanodevices, including nano-superconducting quantum interference devices (nanoSQUIDs), in light of improvements in nanoscale fabrication and manipulation techniques, along with their likely impacts on future quantum technology and measurement. The article first considers efforts to realize devices at the physical scale of 100 nm and below before discussing different types of Josephson junction such as trilayer junctions. It also describes the use of focused ion beam milling and electron beam lithography techniques for junction fabrication at the nanoscale and the improved energy sensitivity detectable with a nanoSQUID. Finally, it looks at a range of applications for nanoSQUIDs, superconducting single photon detectors, and other superconducting nanodevices.