IEEE Transactions on Applied Superconductivity

Millimeter-wave radiation in high-T/sub c/ Josephson junctions

Gerhard Kunkel, Gerd Hechtfischer, Michael Frommberger, K. Veit, R. Kleiner, Paul Müller, W. Prusselt, H. Kinder, L. Ferchland, G. Daalmans, Ronald H. Ono

Published Jun 1, 1997• 10 citations
Publisher

Abstract

We have investigated millimeter-wave radiation from single Josephson junctions and small phase-locked Josephson junction arrays. Josephson junctions were fabricated on sapphire bicrystal substrates. Emission could be measured up to 110 GHz. Resonances in ten-junction circuits yield linewidths narrower than 200 MHz. This type of array might be useful for applications in integrated receiver systems.

DOI
10.1109/77.622080

Related papers

Millimeter-wave self-radiation from high-Tc Josephson junction arrays

Kiejin Lee, Ienari Iguchi, Jeha Kim +2 more

We report the strong microwave Josephson radiation from an array of high-T/sub c/ junctions on a MgO bicrystal substrate from centimeter- to millimeter-wave ranges. The dc bias current was fed to the junction array having parallel geometry with the pair of junctions shunted by superconducting loops. The configuration of bias leads was a series of interlocking dc SQUID's geometry which guaranteed the oscillation of all junctions at the same frequency. The phase differences between adjacent junctions with different I/sub c/R/sub n/ products could be controlled by an external small magnetic field. For a five-junctions array, we observed the coherent output power of about 13 pW without external magnetic flux, which was nearly five times higher than that of a single bicrystal junction. We observed the Josephson linewidth of the self-radiation in the coherent state to be less than 1 GHz by adjustment of the external flux.

IEEE Transactions on Applied Superconductivity•Jun 1, 1997•6 citations

MM wave Josephson radiation in high-Tc bicrystal junction arrays

K. I. Konstantinian, A.D. Mashtakov, G. A. Ovsyannikov +5 more

High-Tc Josephson junction arrays with coupling by superconducting short- circuited (5 µm wide and 0.1 µm thick) coupled microstrip lines, provided dc bias in parallel, were fabricated on bicrystal sapphire substrates for experimental investigation of the phase- locking phenomenon. Josephson self radiation, emitted by the array was measured by an external 90 GHz receiver for different applied dc magnetic fields. The numerical simulation of array shows that strong interaction between Josephson junctions and the standing waves within structure require small enough damping α≤ 10 -3 per coupling section for reduction of Josephson oscillation linewidth.

•Jan 1, 2000•2 citations

Millimeter-wavelength radiation from arrays of discrete high-temperature superconductor Josephson junctions

Fangfang Song, M. Levitchev, Vadim A. Markelov +3 more

Josephson junction arrays could be competitive candidates for radiation sources in the frequency range from 0.5 to 1.5 THz. This is the range where compact solid-state continuous wave sources are most lacking. We investigated the millimeter-wave radiation from arrays of high-temperature superconductor bicrystal Josephson junctions embedded in a quasi-optical resonator. The novel approach of utilizing the intrinsic resonance modes of the substrate to improve the impedance coupling between the series array of discrete Josephson junctions and the quasi-optical resonator was investigated by experiments and electromagnetic field simulations. Radiation from the arrays containing up to 536 junctions was detected at about 80 GHz and liquid nitrogen temperature using a low-noise receiver. The detected maximum radiation power of the arrays was about 50 pW and the peak voltage agreed exactly with the Josephson current–voltage relation.

Superconductor Science and Technology•Feb 22, 2010•5 citations

Hilbert-transform spectral analysis of millimeter- and submillimeter-wave radiation with high T/sub c/ Josephson junctions

Yu. Ya. Divin, Valery V. Pavlovskiy, O. Yu. Volkov +4 more

We have demonstrated the first applications of Josephson-effect-based Hilbert-transform spectral analysis using high-T/sub c/ Josephson junctions. YBa/sub 2/Cu/sub 3/O/sub 7-x/ grain-boundary Josephson junctions have been fabricated on [110] NdGaO/sub 3/ bicrystal substrates for these measurements. At first, spectra of Josephson radiation have been measured by the Hilbert-transform technique in the range 60-800 GHz. A Lorentzian shape of the Josephson radiation and the possibility to obtain a spectral resolution as low as 0.1 cm/sup -1/ in the submillimeter-wave range has been demonstrated at liquid nitrogen temperature. Moreover, spectra of high-harmonic content of the radiation coming from commercial millimeter-wave oscillators have been measured in the spectral range from 60 to 450 GHz. A comparison of Hilbert-transform spectral analysis with conventional techniques is given.

IEEE Transactions on Applied Superconductivity•Jun 1, 1997•4 citations

Millimeter wavelength coherent emission from high temperature superconducting bicrystal Josephson junction array

Yue Hong-Wei, Zheng Wang, Fan Bin +6 more

The experimental results of mm-wave coherent emission from a high temperature superconducting bicrystal Josephson junction array embedded in a Fabry-Perot resonator are reported in this paper.The mm-wave coherent emission from the series junction array results from the interaction of the junctions with the substrate serving as the dielectric resonator as well as the Fabry-Perot resonator.The central frequency of emission of a Josephson junction array containing 166 bicrystal junctions was 75.84 GHz,and the detected emission power was about 10 pW at 77 K.

Acta Physica Sinica•Jan 1, 2010•1 citation

Simulation and measurement of millimeter-wave radiation from Josephson junction array*

Xin Zhang, Shenghui Zhao, Litian Wang +8 more

We report the circuit simulations and experiments of millimeter-wave radiation from a high temperature superconducting (HTS) bicrystal Josephson junction (BJJ) array. To study the effects of junction characteristic parameters on radiation properties, new radiation circuit models are proposed in this paper. The series resistively and capacitively shunted junction (RCSJ) models are packaged into a Josephson junction array (JJA) model in the simulation. The current-voltage characteristics (IVCs) curve and radiation peaks are simulated and analyzed by circuit models, which are also observed from the experiment at liquid nitrogen temperature. The experimental radiation linewidth and power are in good agreement with simulated results. The presented circuit models clearly demonstrate that the inconsistency of the JJA will cause a broad linewidth and a low detected power. The junction radiation properties are also investigated at the optimal situation by circuit simulation. The results further confirm that the consistent JJA characteristic parameters can successfully narrow the radiation linewidth and increase the power of junction radiation.

Chinese Physics B•Jun 1, 2019•1 citation
We have investigated millimeter-wave radiation from single Josephson junctions and small phase-locked Josephson junction arrays. Josephson junctions were fabricated on sapphire bicrystal substrates. Emission could be measured up to 110 GHz. Resonances in ten-junction circuits yield linewidths narrower than 200 MHz. This type of array might be useful for applications in integrated receiver systems.
We report the strong microwave Josephson radiation from an array of high-T/sub c/ junctions on a MgO bicrystal substrate from centimeter- to millimeter-wave ranges. The dc bias current was fed to the junction array having parallel geometry with the pair of junctions shunted by superconducting loops. The configuration of bias leads was a series of interlocking dc SQUID's geometry which guaranteed the oscillation of all junctions at the same frequency. The phase differences between adjacent junctions with different I/sub c/R/sub n/ products could be controlled by an external small magnetic field. For a five-junctions array, we observed the coherent output power of about 13 pW without external magnetic flux, which was nearly five times higher than that of a single bicrystal junction. We observed the Josephson linewidth of the self-radiation in the coherent state to be less than 1 GHz by adjustment of the external flux.
High-Tc Josephson junction arrays with coupling by superconducting short- circuited (5 µm wide and 0.1 µm thick) coupled microstrip lines, provided dc bias in parallel, were fabricated on bicrystal sapphire substrates for experimental investigation of the phase- locking phenomenon. Josephson self radiation, emitted by the array was measured by an external 90 GHz receiver for different applied dc magnetic fields. The numerical simulation of array shows that strong interaction between Josephson junctions and the standing waves within structure require small enough damping α≤ 10 -3 per coupling section for reduction of Josephson oscillation linewidth.
Josephson junction arrays could be competitive candidates for radiation sources in the frequency range from 0.5 to 1.5 THz. This is the range where compact solid-state continuous wave sources are most lacking. We investigated the millimeter-wave radiation from arrays of high-temperature superconductor bicrystal Josephson junctions embedded in a quasi-optical resonator. The novel approach of utilizing the intrinsic resonance modes of the substrate to improve the impedance coupling between the series array of discrete Josephson junctions and the quasi-optical resonator was investigated by experiments and electromagnetic field simulations. Radiation from the arrays containing up to 536 junctions was detected at about 80 GHz and liquid nitrogen temperature using a low-noise receiver. The detected maximum radiation power of the arrays was about 50 pW and the peak voltage agreed exactly with the Josephson current–voltage relation.
We have demonstrated the first applications of Josephson-effect-based Hilbert-transform spectral analysis using high-T/sub c/ Josephson junctions. YBa/sub 2/Cu/sub 3/O/sub 7-x/ grain-boundary Josephson junctions have been fabricated on [110] NdGaO/sub 3/ bicrystal substrates for these measurements. At first, spectra of Josephson radiation have been measured by the Hilbert-transform technique in the range 60-800 GHz. A Lorentzian shape of the Josephson radiation and the possibility to obtain a spectral resolution as low as 0.1 cm/sup -1/ in the submillimeter-wave range has been demonstrated at liquid nitrogen temperature. Moreover, spectra of high-harmonic content of the radiation coming from commercial millimeter-wave oscillators have been measured in the spectral range from 60 to 450 GHz. A comparison of Hilbert-transform spectral analysis with conventional techniques is given.
The experimental results of mm-wave coherent emission from a high temperature superconducting bicrystal Josephson junction array embedded in a Fabry-Perot resonator are reported in this paper.The mm-wave coherent emission from the series junction array results from the interaction of the junctions with the substrate serving as the dielectric resonator as well as the Fabry-Perot resonator.The central frequency of emission of a Josephson junction array containing 166 bicrystal junctions was 75.84 GHz,and the detected emission power was about 10 pW at 77 K.
We report the circuit simulations and experiments of millimeter-wave radiation from a high temperature superconducting (HTS) bicrystal Josephson junction (BJJ) array. To study the effects of junction characteristic parameters on radiation properties, new radiation circuit models are proposed in this paper. The series resistively and capacitively shunted junction (RCSJ) models are packaged into a Josephson junction array (JJA) model in the simulation. The current-voltage characteristics (IVCs) curve and radiation peaks are simulated and analyzed by circuit models, which are also observed from the experiment at liquid nitrogen temperature. The experimental radiation linewidth and power are in good agreement with simulated results. The presented circuit models clearly demonstrate that the inconsistency of the JJA will cause a broad linewidth and a low detected power. The junction radiation properties are also investigated at the optimal situation by circuit simulation. The results further confirm that the consistent JJA characteristic parameters can successfully narrow the radiation linewidth and increase the power of junction radiation.