Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

New Journal of Physics

The influence of transverse motion within an atomic gravimeter

Anne Louchet-Chauvet, Tristan Farah, Quentin Bodart, André Clairon, Arnaud Landragin, Sébastien Merlet, Franck Pereira dos Santos

Published Jun 28, 2011• 263 citations
Publisher

Abstract

Limits on the long-term stability and accuracy of a second generation cold atom gravimeter are investigated. We demonstrate a measurement protocol based on four interleaved measurement configurations, which allows rejection of most of the systematic effects, but not those related to Coriolis acceleration and wave-front distortions. Both are related to the transverse motion of the atomic cloud. Carrying out measurements with opposite orientations with respect to the Earth's rotation vector direction allows us to separate the effects and correct for the Coriolis shift. Finally, measurements at different atomic temperatures are presented and analyzed. In particular, we show the difficulty of extrapolating these measurements to zero temperature, which is required in order to correct for the bias due to wave-front distortions.

DOI
10.1088/1367-2630/13/6/065025

Related papers

High-Sensitivity Absolute Atomic Gravimeter

Christine Guerlin, Tristan Farah, Anne Louchet-Chauvet +2 more

Cold atom free-fall interferometers now realize state-of-the-art precision inertial sensors, opening perspectives towards embedded devices for applications and fundamental physics tests on earth and in space. The acceleration of gravity can be measured in a stimulated Raman transition interferometer where the acceleration under gravity of a cloud of freely falling atoms is sensed by three Raman pulses allowing to split, reflect and interfere atomic wave packets [1]. The gravimeter developped at SYRTE allows to measure the acceleration of gravity at state-of-the-art performances compared to the best classical absolute gravimeters, with a sensitivity of 2×10−8g over 1s and an exactitude of 5×10−9 g [2]. This exactitude is currently limited by wavefront aberrations of the lasers, sampled by residual transverse trajectories of the molasse-cooled cloud over the free fall. Unbalanced transverse trajectories will also bias the measurement due to Coriolis effect [3]. We will investigate the use of a colder atom source to reduce these systematic effects, by implementing Bose-Einstein condensation of the initial cloud, allowing both better position control and better focusing of our source.

Research in Optical Sciences•Jan 1, 2012•0 citations

Dependence of the sensitivity on the orientation for a free-fall atom gravimeter

Bin Yang Wu, Dong Zhu, Bing Cheng +8 more

The cold atom absolute gravimeters are intrinsically sensitive to its orientation due to the Coriolis effect, which should be understood clearly and compensated for field applications. The sensitivity on the orientation for a free-fall atom gravimeter is investigated in this paper. The apparatus is simplified and improved a lot such that fast adjustment and measurement could be carried out within 20 minutes. From the experimental results, it is found that the orientation angle has a dominant influence on the absolute gravity measurement, especially when the horizontal velocity of atoms is non-negligible. Besides, the magnitude and direction of average horizontal velocity of the detected atoms are obtained in this experiment. In particular, the direction of East-West has been measured by the atom gravimeter itself, such that gravity bias arising from Coriolis effect is estimated precisely.

Optics Express•Apr 8, 2019•21 citations

Improving the Accuracy of Atom Gravimeters with Ultracold Sources

Romain Karcher, Almazbek Imanaliev, Sébastien Merlet +1 more

Summary form only given. Atom interferometry based on cold atoms and light beamsplitters is a mature technique, which allows for the realization of highly sensitive inertial sensors. In the most advanced inertial sensors based on atom interferometry, atomic wavepackets are manipulated by light beamsplitters using two-photon Raman transitions. The interferometer phase shift, which depends on the acceleration and the rotation of the experimental setup with respect to the inertial reference frame defined by the atoms in free fall, is derived from the relative displacement of the atoms with respect to the beamsplitter laser's equiphases. Wavefront aberrations thus induce parasitic phase shifts, which bias the measurement, and which are linked to the residual ballistic motion of the atoms across the laser beam profile during their free fall and cancels out at zero atomic temperature. The wavefront distortions of the lasers beamsplitters is an important limit in the accuracy of atom interferometers and in particular, the dominating contribution in best cold atom gravimeters (CAG) uncertainty budget. This work clears the way towards unprecedented accuracies for absolute gravimetry, below the 1 μGal level. The method proposed can be applied to any atomic sensor based on light beamsplitters, which are inevitably affected by distortions of the lasers wavefronts. The improved control of systematics it provides will have significant impact in high precision measurements with atom interferometry, with important applications to geodesy, fundamental physics tests and to the development of highest grade inertial sensors.

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•Jun 1, 2019•0 citations

An atom interferometer for measuring horizontal accelerations

Jimmy Stammers

Matter-wave interferometry has enabled high precision measurements of inertial forces such as gravity and the Coriolis force. This is facilitated by the long-term stability of the physical properties of atoms and lasers. Recent experiments have demonstrated the operation of portable, robust sensors using atom interferometry. This has potential uses in the context of inertial navigation, where conventional devices suffer from long-term drifts due to bias instability. Furthermore, determining position via dead reckoning requires minimisation of dead time between measurements. This thesis presents the development of an atom interferometer for measuring horizontal accelerations. In this configuration, gravity induces motion across the laser wavefront, which constrains the tolerable level of wavefront distortions. Effective control of the experiment allows the interferometer to be operated at a rate of 4 Hz. A cold ensemble of 10^6 atoms in the same internal state is prepared in 150 ms. The interferometer operates using a sequence of three laser pulses separated by T= 25 ms to achieve sensitivity to horizontal accelerations. Combining this with a classical accelerometer provides a method of correcting for vibration-induced noise, as well as determining the interferometer fringe order. After an integration time of 40 s, the sensitivity to horizontal accelerations is better than 3^-6 m s^-2. Effects which limit this sensitivity are discussed.

•Nov 1, 2018•6 citations

Effective velocity distribution in an atom gravimeter: Effect of the convolution with the response of the detection

Tristan Farah, Pierre Gillot, Bing Cheng +3 more

We present here a detailed study of the influence of the transverse motion of the atoms in a free-fall gravimeter. By implementing Raman selection in the horizontal directions at the beginning of the atoms' free fall, we characterize the effective velocity distribution, i.e., the velocity distribution of the detected atom, as a function of the laser cooling and trapping parameters. In particular, we show that the response of the detection induces a pronounced asymmetry of this effective velocity distribution that depends not only on the imbalance between molasses beams but also on the initial position of the displaced atomic sample. This convolution with the detection has a strong influence on the averaging of the bias due to Coriolis acceleration. The present study allows a fairly good understanding of results previously published in [New J. Phys. 13, 065025 (2011)], where the mean phase shift due to Coriolis acceleration was found to have a sign different from that expected.

arXiv:1406.5998•Physical Review A•Aug 6, 2014•27 citations

Improving the accuracy of atom interferometers with ultracold sources

Romain Karcher, Almazbek Imanaliev, Sébastien Merlet +1 more

We report on the implementation of ultracold atoms as a source in a state of the art atom gravimeter. We perform gravity measurements with 10 nm s −2 statistical uncertainties in a so-far largely unexplored temperature range for such a high accuracy sensor, down to 50 nK. This allows for an improved characterization of the most limiting systematic effect, related to wavefront aberrations of light beamsplitters. A thorough model of the impact of this effect onto the measurement is developed and a method is proposed to correct for this bias based on the extrapolation of the measurements down to zero temperature. Finally, an uncertainty of 13 nm s −2 is obtained in the evaluation of this systematic effect, which can be improved further by performing measurements at even lower temperatures. Our results clearly demonstrate the benefit brought by ultracold atoms to the metrological study of free falling atom interferometers. By tackling their main limitation, the method presented here allows reaching record-breaking accuracies for inertial sensors based on atom interferometry.

arXiv:1804.04909•New Journal of Physics•Nov 13, 2018•123 citations
Limits on the long-term stability and accuracy of a second generation cold atom gravimeter are investigated. We demonstrate a measurement protocol based on four interleaved measurement configurations, which allows rejection of most of the systematic effects, but not those related to Coriolis acceleration and wave-front distortions. Both are related to the transverse motion of the atomic cloud. Carrying out measurements with opposite orientations with respect to the Earth's rotation vector direction allows us to separate the effects and correct for the Coriolis shift. Finally, measurements at different atomic temperatures are presented and analyzed. In particular, we show the difficulty of extrapolating these measurements to zero temperature, which is required in order to correct for the bias due to wave-front distortions.
Cold atom free-fall interferometers now realize state-of-the-art precision inertial sensors, opening perspectives towards embedded devices for applications and fundamental physics tests on earth and in space. The acceleration of gravity can be measured in a stimulated Raman transition interferometer where the acceleration under gravity of a cloud of freely falling atoms is sensed by three Raman pulses allowing to split, reflect and interfere atomic wave packets [1]. The gravimeter developped at SYRTE allows to measure the acceleration of gravity at state-of-the-art performances compared to the best classical absolute gravimeters, with a sensitivity of 2×10−8g over 1s and an exactitude of 5×10−9 g [2]. This exactitude is currently limited by wavefront aberrations of the lasers, sampled by residual transverse trajectories of the molasse-cooled cloud over the free fall. Unbalanced transverse trajectories will also bias the measurement due to Coriolis effect [3]. We will investigate the use of a colder atom source to reduce these systematic effects, by implementing Bose-Einstein condensation of the initial cloud, allowing both better position control and better focusing of our source.
The cold atom absolute gravimeters are intrinsically sensitive to its orientation due to the Coriolis effect, which should be understood clearly and compensated for field applications. The sensitivity on the orientation for a free-fall atom gravimeter is investigated in this paper. The apparatus is simplified and improved a lot such that fast adjustment and measurement could be carried out within 20 minutes. From the experimental results, it is found that the orientation angle has a dominant influence on the absolute gravity measurement, especially when the horizontal velocity of atoms is non-negligible. Besides, the magnitude and direction of average horizontal velocity of the detected atoms are obtained in this experiment. In particular, the direction of East-West has been measured by the atom gravimeter itself, such that gravity bias arising from Coriolis effect is estimated precisely.
Summary form only given. Atom interferometry based on cold atoms and light beamsplitters is a mature technique, which allows for the realization of highly sensitive inertial sensors. In the most advanced inertial sensors based on atom interferometry, atomic wavepackets are manipulated by light beamsplitters using two-photon Raman transitions. The interferometer phase shift, which depends on the acceleration and the rotation of the experimental setup with respect to the inertial reference frame defined by the atoms in free fall, is derived from the relative displacement of the atoms with respect to the beamsplitter laser's equiphases. Wavefront aberrations thus induce parasitic phase shifts, which bias the measurement, and which are linked to the residual ballistic motion of the atoms across the laser beam profile during their free fall and cancels out at zero atomic temperature. The wavefront distortions of the lasers beamsplitters is an important limit in the accuracy of atom interferometers and in particular, the dominating contribution in best cold atom gravimeters (CAG) uncertainty budget. This work clears the way towards unprecedented accuracies for absolute gravimetry, below the 1 μGal level. The method proposed can be applied to any atomic sensor based on light beamsplitters, which are inevitably affected by distortions of the lasers wavefronts. The improved control of systematics it provides will have significant impact in high precision measurements with atom interferometry, with important applications to geodesy, fundamental physics tests and to the development of highest grade inertial sensors.
Matter-wave interferometry has enabled high precision measurements of inertial forces such as gravity and the Coriolis force. This is facilitated by the long-term stability of the physical properties of atoms and lasers. Recent experiments have demonstrated the operation of portable, robust sensors using atom interferometry. This has potential uses in the context of inertial navigation, where conventional devices suffer from long-term drifts due to bias instability. Furthermore, determining position via dead reckoning requires minimisation of dead time between measurements. This thesis presents the development of an atom interferometer for measuring horizontal accelerations. In this configuration, gravity induces motion across the laser wavefront, which constrains the tolerable level of wavefront distortions. Effective control of the experiment allows the interferometer to be operated at a rate of 4 Hz. A cold ensemble of 10^6 atoms in the same internal state is prepared in 150 ms. The interferometer operates using a sequence of three laser pulses separated by T= 25 ms to achieve sensitivity to horizontal accelerations. Combining this with a classical accelerometer provides a method of correcting for vibration-induced noise, as well as determining the interferometer fringe order. After an integration time of 40 s, the sensitivity to horizontal accelerations is better than 3^-6 m s^-2. Effects which limit this sensitivity are discussed.
We present here a detailed study of the influence of the transverse motion of the atoms in a free-fall gravimeter. By implementing Raman selection in the horizontal directions at the beginning of the atoms' free fall, we characterize the effective velocity distribution, i.e., the velocity distribution of the detected atom, as a function of the laser cooling and trapping parameters. In particular, we show that the response of the detection induces a pronounced asymmetry of this effective velocity distribution that depends not only on the imbalance between molasses beams but also on the initial position of the displaced atomic sample. This convolution with the detection has a strong influence on the averaging of the bias due to Coriolis acceleration. The present study allows a fairly good understanding of results previously published in [New J. Phys. 13, 065025 (2011)], where the mean phase shift due to Coriolis acceleration was found to have a sign different from that expected.
We report on the implementation of ultracold atoms as a source in a state of the art atom gravimeter. We perform gravity measurements with 10 nm s −2 statistical uncertainties in a so-far largely unexplored temperature range for such a high accuracy sensor, down to 50 nK. This allows for an improved characterization of the most limiting systematic effect, related to wavefront aberrations of light beamsplitters. A thorough model of the impact of this effect onto the measurement is developed and a method is proposed to correct for this bias based on the extrapolation of the measurements down to zero temperature. Finally, an uncertainty of 13 nm s −2 is obtained in the evaluation of this systematic effect, which can be improved further by performing measurements at even lower temperatures. Our results clearly demonstrate the benefit brought by ultracold atoms to the metrological study of free falling atom interferometers. By tackling their main limitation, the method presented here allows reaching record-breaking accuracies for inertial sensors based on atom interferometry.