Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1804.04909 · New Journal of Physics

Improving the accuracy of atom interferometers with ultracold sources

Romain Karcher, Almazbek Imanaliev, Sébastien Merlet, Franck Pereira dos Santos

Published Nov 13, 2018• 123 citations
arXivHTMLPDF

Abstract

We report on the implementation of ultracold atoms as a source in a state of the art atom gravimeter. We perform gravity measurements with 10 nm s −2 statistical uncertainties in a so-far largely unexplored temperature range for such a high accuracy sensor, down to 50 nK. This allows for an improved characterization of the most limiting systematic effect, related to wavefront aberrations of light beamsplitters. A thorough model of the impact of this effect onto the measurement is developed and a method is proposed to correct for this bias based on the extrapolation of the measurements down to zero temperature. Finally, an uncertainty of 13 nm s −2 is obtained in the evaluation of this systematic effect, which can be improved further by performing measurements at even lower temperatures. Our results clearly demonstrate the benefit brought by ultracold atoms to the metrological study of free falling atom interferometers. By tackling their main limitation, the method presented here allows reaching record-breaking accuracies for inertial sensors based on atom interferometry.

DOI
10.1088/1367-2630/aaf07d

Related papers

Improving the Accuracy of Atom Gravimeters with Ultracold Sources

Romain Karcher, Almazbek Imanaliev, Sébastien Merlet +1 more

Summary form only given. Atom interferometry based on cold atoms and light beamsplitters is a mature technique, which allows for the realization of highly sensitive inertial sensors. In the most advanced inertial sensors based on atom interferometry, atomic wavepackets are manipulated by light beamsplitters using two-photon Raman transitions. The interferometer phase shift, which depends on the acceleration and the rotation of the experimental setup with respect to the inertial reference frame defined by the atoms in free fall, is derived from the relative displacement of the atoms with respect to the beamsplitter laser's equiphases. Wavefront aberrations thus induce parasitic phase shifts, which bias the measurement, and which are linked to the residual ballistic motion of the atoms across the laser beam profile during their free fall and cancels out at zero atomic temperature. The wavefront distortions of the lasers beamsplitters is an important limit in the accuracy of atom interferometers and in particular, the dominating contribution in best cold atom gravimeters (CAG) uncertainty budget. This work clears the way towards unprecedented accuracies for absolute gravimetry, below the 1 μGal level. The method proposed can be applied to any atomic sensor based on light beamsplitters, which are inevitably affected by distortions of the lasers wavefronts. The improved control of systematics it provides will have significant impact in high precision measurements with atom interferometry, with important applications to geodesy, fundamental physics tests and to the development of highest grade inertial sensors.

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•Jun 1, 2019•0 citations

High-Sensitivity Absolute Atomic Gravimeter

Christine Guerlin, Tristan Farah, Anne Louchet-Chauvet +2 more

Cold atom free-fall interferometers now realize state-of-the-art precision inertial sensors, opening perspectives towards embedded devices for applications and fundamental physics tests on earth and in space. The acceleration of gravity can be measured in a stimulated Raman transition interferometer where the acceleration under gravity of a cloud of freely falling atoms is sensed by three Raman pulses allowing to split, reflect and interfere atomic wave packets [1]. The gravimeter developped at SYRTE allows to measure the acceleration of gravity at state-of-the-art performances compared to the best classical absolute gravimeters, with a sensitivity of 2×10−8g over 1s and an exactitude of 5×10−9 g [2]. This exactitude is currently limited by wavefront aberrations of the lasers, sampled by residual transverse trajectories of the molasse-cooled cloud over the free fall. Unbalanced transverse trajectories will also bias the measurement due to Coriolis effect [3]. We will investigate the use of a colder atom source to reduce these systematic effects, by implementing Bose-Einstein condensation of the initial cloud, allowing both better position control and better focusing of our source.

Research in Optical Sciences•Jan 1, 2012•0 citations

Ultracold Atom Gravimeter

Sébastien Merlet, Romain Karcher, Almazbek Imanaliev +1 more

Atom interferometry allows for the realisation of inertial sensors based on laser cooled atoms. Their limits in performances, both in terms of accuracy and stability, are linked to the temperature of the atomic cloud, in the low μK range, and more specifically, to the residual ballistic expansion of the atomic sources in the laser beams. To overcome these limits, we use as a source ultracold atoms in the nano-kelvin range in our absolute atom gravimeter.

Conference on Precision Electromagnetic Measurements•Jul 1, 2018•2 citations

The effect of wavefront aberrations in atom interferometry

Vladimir Schkolnik, Bastian Leykauf, Matthias Hauth +2 more

Wavefront aberrations are one of the largest uncertainty factors in present atom interferometers. We present a detailed numerical and experimental analysis of this effect based on measured aberrations from optical windows. By placing windows into the Raman beam path of our atomic gravimeter, we verify for the first time the induced bias in very good agreement with theory. Our method can be used to reduce the uncertainty in atomic gravimeters by one order of magnitude resulting in an error of less than 3 × 10−10 g and it is suitable in a wide variety of atom interferometers with thermal or ultra cold atoms. We discuss the limitations of our method, potential improvements and its role in future generation experiments. 1

•Aug 17, 2016•83 citations

Precision gravity measurements with cold atom interferometer

Qin Luo, Zhong-Kun Hu, Dekai Mao +7 more

Cold-atom interferometer based on stimulated Raman transition is interesting for both fundamental researches and precision measurements. Measuring g, the free fall acceleration, plays an important role in these applications. We describe the theory of atom interferometry, including the evolution of the atomic wavepacket in gravity field, the laser-atom interaction, and the interference of the atomic waves. In this article, we introduce the procedure of measuring g using atom interferometer, the experimental setup, and the tendency of the future development. The works of the domestic and international groups for g measurement are concluded. Furthermore, the noise limits and dominant systematic effects in atom gravimeters are analyzed. The suppressions of the background vibration, the Raman phase noise, and the evaluation of the main systematic effects, are introduced. Finally, the other applications using the atom interferometers for precision measurement are presented, such as in measuring the Newton’s gravitational constant, in testing the weak equivalence principle and the other fundamental applications in physics studies.

Zhongguo kexue. Wulixue Lixue Tianwenxue•Jun 15, 2016•5 citations

Wavefront Mapping for Absolute Atom Interferometry

Joseph Junca, John E. Kitching, William McGehee

Wavefront distortions are a leading source of systematic uncertainty in light-pulse atom interferometry, limiting absolute measurements of gravitational acceleration at the 30 nm/s^{2} level. Here, we demonstrate in situ spatially resolved measurement of the interferometer phase in a Mach-Zehnder atom interferometer as a tool to characterize and correct wavefront bias. By introducing controllable curvature of the Raman light using an adjustable collimation retro-reflector, we show that the bias due to parabolic wavefront curvature can be measured with 1 mrad uncertainty and that finite-size corrections impact the measured phase curvature. This measurement process could be adopted in optimized atom interferometer gravimeters to reduce wavefront bias uncertainty below the nm/s^{2} level.

arXiv:2507.23052•Physical Review Letters•Mar 12, 2026•3 citations
We report on the implementation of ultracold atoms as a source in a state of the art atom gravimeter. We perform gravity measurements with 10 nm s −2 statistical uncertainties in a so-far largely unexplored temperature range for such a high accuracy sensor, down to 50 nK. This allows for an improved characterization of the most limiting systematic effect, related to wavefront aberrations of light beamsplitters. A thorough model of the impact of this effect onto the measurement is developed and a method is proposed to correct for this bias based on the extrapolation of the measurements down to zero temperature. Finally, an uncertainty of 13 nm s −2 is obtained in the evaluation of this systematic effect, which can be improved further by performing measurements at even lower temperatures. Our results clearly demonstrate the benefit brought by ultracold atoms to the metrological study of free falling atom interferometers. By tackling their main limitation, the method presented here allows reaching record-breaking accuracies for inertial sensors based on atom interferometry.
Summary form only given. Atom interferometry based on cold atoms and light beamsplitters is a mature technique, which allows for the realization of highly sensitive inertial sensors. In the most advanced inertial sensors based on atom interferometry, atomic wavepackets are manipulated by light beamsplitters using two-photon Raman transitions. The interferometer phase shift, which depends on the acceleration and the rotation of the experimental setup with respect to the inertial reference frame defined by the atoms in free fall, is derived from the relative displacement of the atoms with respect to the beamsplitter laser's equiphases. Wavefront aberrations thus induce parasitic phase shifts, which bias the measurement, and which are linked to the residual ballistic motion of the atoms across the laser beam profile during their free fall and cancels out at zero atomic temperature. The wavefront distortions of the lasers beamsplitters is an important limit in the accuracy of atom interferometers and in particular, the dominating contribution in best cold atom gravimeters (CAG) uncertainty budget. This work clears the way towards unprecedented accuracies for absolute gravimetry, below the 1 μGal level. The method proposed can be applied to any atomic sensor based on light beamsplitters, which are inevitably affected by distortions of the lasers wavefronts. The improved control of systematics it provides will have significant impact in high precision measurements with atom interferometry, with important applications to geodesy, fundamental physics tests and to the development of highest grade inertial sensors.
Cold atom free-fall interferometers now realize state-of-the-art precision inertial sensors, opening perspectives towards embedded devices for applications and fundamental physics tests on earth and in space. The acceleration of gravity can be measured in a stimulated Raman transition interferometer where the acceleration under gravity of a cloud of freely falling atoms is sensed by three Raman pulses allowing to split, reflect and interfere atomic wave packets [1]. The gravimeter developped at SYRTE allows to measure the acceleration of gravity at state-of-the-art performances compared to the best classical absolute gravimeters, with a sensitivity of 2×10−8g over 1s and an exactitude of 5×10−9 g [2]. This exactitude is currently limited by wavefront aberrations of the lasers, sampled by residual transverse trajectories of the molasse-cooled cloud over the free fall. Unbalanced transverse trajectories will also bias the measurement due to Coriolis effect [3]. We will investigate the use of a colder atom source to reduce these systematic effects, by implementing Bose-Einstein condensation of the initial cloud, allowing both better position control and better focusing of our source.
Wavefront aberrations are one of the largest uncertainty factors in present atom interferometers. We present a detailed numerical and experimental analysis of this effect based on measured aberrations from optical windows. By placing windows into the Raman beam path of our atomic gravimeter, we verify for the first time the induced bias in very good agreement with theory. Our method can be used to reduce the uncertainty in atomic gravimeters by one order of magnitude resulting in an error of less than 3 × 10−10 g and it is suitable in a wide variety of atom interferometers with thermal or ultra cold atoms. We discuss the limitations of our method, potential improvements and its role in future generation experiments. 1
Cold-atom interferometer based on stimulated Raman transition is interesting for both fundamental researches and precision measurements. Measuring g, the free fall acceleration, plays an important role in these applications. We describe the theory of atom interferometry, including the evolution of the atomic wavepacket in gravity field, the laser-atom interaction, and the interference of the atomic waves. In this article, we introduce the procedure of measuring g using atom interferometer, the experimental setup, and the tendency of the future development. The works of the domestic and international groups for g measurement are concluded. Furthermore, the noise limits and dominant systematic effects in atom gravimeters are analyzed. The suppressions of the background vibration, the Raman phase noise, and the evaluation of the main systematic effects, are introduced. Finally, the other applications using the atom interferometers for precision measurement are presented, such as in measuring the Newton’s gravitational constant, in testing the weak equivalence principle and the other fundamental applications in physics studies.
Wavefront distortions are a leading source of systematic uncertainty in light-pulse atom interferometry, limiting absolute measurements of gravitational acceleration at the 30 nm/s^{2} level. Here, we demonstrate in situ spatially resolved measurement of the interferometer phase in a Mach-Zehnder atom interferometer as a tool to characterize and correct wavefront bias. By introducing controllable curvature of the Raman light using an adjustable collimation retro-reflector, we show that the bias due to parabolic wavefront curvature can be measured with 1 mrad uncertainty and that finite-size corrections impact the measured phase curvature. This measurement process could be adopted in optimized atom interferometer gravimeters to reduce wavefront bias uncertainty below the nm/s^{2} level.