Microchip‐Based Trapped‐Atom Clocks

Vladan Vuletić, Ian D. Leroux, Monika Schleier-Smith

Published Feb 9, 2011• 3 citations
Publisher

Abstract

In the absence of other fields, particles fall under gravity, which sets a practical limit on the single-measurement time T. Atomic fountains, where an ensemble of atoms is launched upwards into a ballistic flight region, allow one to increase the measurement time. Since the fractional accuracy of an atomic clock improves with increasing transition frequency, it is natural to consider the use of optical-frequency electronic transitions rather than microwave-frequency hyperfine transitions as the basis for a clock. Clocks operating on optical transitions have already surpassed the much more mature hyperfine-transition atomic-fountain clocks in accuracy, and further improvements are expected. In practice, however, the allowable atom number is severely limited by the onset of collision shifts which, as seen, are the bane of compact trapped-atom clocks. Spin squeezing of superpositions of clock states is an active research area, with several recently demonstrated implementations. Controlled Vocabulary Terms atomic clocks; optical squeezing

DOI
10.1002/9783527633357.ch8

Related papers

Microchip-Based Trapped-Atom Clocks

Vladan Vuletić, Ian D. Leroux, Monika Schleier-Smith

This is a chapter of a recently published book entitled Atom Chips, edited by Jakob Reichel and Vladan Vuletic. The contents of this chapter include: Basic Principles; Atomic-Fountain versus Trapped-Atom Clocks; Optical-Transition Clocks versus Microwave Clocks; Clocks with Magnetically Trapped Atoms--Fundamental Limits and Experimental Demonstrations; Readout in Trapped-Atom Clocks; and Spin Squeezing.

arXiv:1104.4142•Apr 20, 2011•0 citations

Trapped-ion optical Atomic Clocks at the Quantum Limits

David R. Leibrandt, Samuel M. Brewer, Jwo-Sy Chen +4 more

Frequency and its inverse, time, are the most accurately measured quantities. Historically, improvements in the accuracy of clocks have enabled advances in navigation, communication, and science. Since 1967, the definition of the International System (SI) second has been based on the frequency of a microwave transition in cesium, and present day cesium atomic clocks have a fractional uncertainty near 10-16. Recently, a new type of atomic clock based on optical transitions has been developed, with a current fractional uncertainty near 10-18 (approximately one second divided by the age of the universe), and they are rapidly improving. This talk presents a brief summary of the development of optical atomic clocks, with a focus on the Al+ quantum-logic clock developed at NIST. We discuss the current state-of-the-art in optical clock performance, and describe new applications in sensing and fundamental physics. Future directions in optical atomic clock research are also considered.

Proceedings of the ... annual Precise Time and Time Interval (PTTI) Systems and Applications Meeting/Proceedings of a meeting - Precise Time and Time Interval (PTTI) Systems and Applications Meeting•Mar 7, 2017•2 citations

particular 'magic' wavelengths. This Review covers the experimental realizations of such clocks, the optimal design of optical lattices and recent demonstrations of improved stability for large numbers of atoms. Possible impacts and future applications of optical lattice clocks are also discussed, such as testing the fundamental laws of physics and developing relativistic geodesy.

Louis Essen

8half a century ago and have provided the definition of the second since 1967. The international atomic time (TAI) is currently kept by an ensemble of Cs clocks with a fractional uncertainty of Δν/ν0 ≈ 10 –15 , and some Cs fountain clocks 9,10 operate at even smaller uncertainties. Although Cs atomic clocks operate at the microwave transition of ν0 ≈ 9.2 GHz, using optical transition frequencies of several hundred terahertz should improve the fractional uncertainty Δν/ν0 by 4–5 orders of magnitude, as most measurement uncertainties Δν are independent of ν0 (except the Doppler shift Δ νD = (v/c)ν0, where v is the atomic velocity and c is the speed of light). The invention of the laser and the subsequent improvement of laser frequency stabilities 11 has allowed the realization of optical clocks to become a reality 2,3,12

•Jan 1, 2011•0 citations

Other applications of laser cooling and trapping

Richard A. Dunlap

The final chapter of this book considers some applications of ultracold atoms in addition to the study of Bose–Einstein condensates. These applications focus largely on the use of ultracold atoms for the purpose of constructing a highly accurate atomic clock. These clocks include atomic fountain clocks, which are presently used for the definition of the second. These clocks operate at microwave frequencies by observing the transitions between hyperfine split atomic ground states. More recent developments in atomic clocks utilize optical transitions between the ground state and an excited atomic state and typically utilize atoms trapped in an optical lattice.

Institute of Physics eBooks•May 1, 2023•0 citations

Future of neutral atom clocks

Steven Chu, Mark A. Kasevich, Kathryn A. Moler +2 more

The measurement on energy levels suitable for time standards can be made more precise with the use of neutral atom manipulation techniques. We have created a fountain of atoms where the measurement time of atoms in ballistic free-fall can be on the order of a fraction of a second. With these long measurement times, the linewidth of the transition between the ground state hyperfine transition of sodium was measured to be 2 Hz. Transitions in the optical frequency range could then have Q's of 1014 to 1015. In addition to creating high Q resonances, it is desirable to have a continuous, high density fountain of atoms. Towards this end, we have constructed an "atomic funnel" capable of creating a cold, high flux stream of atoms suitable for injection into a continuous atomic fountain. In the first embodiment of the funnel, the brightness of the atomic beam (defined as the number of atoms per second/( ΔvxΔvyΔvz) was increased by a factor of 3 × 103. With more recent improvements for both funneling more atoms from the hot atomic beam and better use of polarization gradient cooling to launch the atoms, we will describe how to improve the brightness enhancement by another four orders of magnitude.

Annual Meeting Optical Society of America•Jan 1, 1990•0 citations

Atomic Fountain Microwave Clock.

Steven Chu

Abstract : The grant as in support of a research program to explore the possibility of a microwave atomic clock based on an atomic fountain of cesium atoms. During the two year granting period, the following work was done: A large magneto-optic trap in a vapor cell was constructed where over 4x 10(exp 10) atoms were trapped at a density on the order of 10(exp 11) atoms/cu cm. This work increased the number of atoms optically trapped by a factor of -400 compared to previous work. The optical density of the atoms in this trap has a peak attenuation of e(-175). In an invited review article we examined the prospects for slow atom frequency standards. Most of the systematic effects that limit the current accuracy today's frequency standards decrease as the velocity of the atoms is reduced. We identified the one possible exception: collisions between ultra-cold atom in an atomic fountain could induce a phase shift that would ultimately limit the accuracy of the fountain clock. We brought the problem to the attention of B. Verhaar, who began a series of calculations on the effects of low energy collisions. jg p.4

•Jul 7, 1994•0 citations
In the absence of other fields, particles fall under gravity, which sets a practical limit on the single-measurement time T. Atomic fountains, where an ensemble of atoms is launched upwards into a ballistic flight region, allow one to increase the measurement time. Since the fractional accuracy of an atomic clock improves with increasing transition frequency, it is natural to consider the use of optical-frequency electronic transitions rather than microwave-frequency hyperfine transitions as the basis for a clock. Clocks operating on optical transitions have already surpassed the much more mature hyperfine-transition atomic-fountain clocks in accuracy, and further improvements are expected. In practice, however, the allowable atom number is severely limited by the onset of collision shifts which, as seen, are the bane of compact trapped-atom clocks. Spin squeezing of superpositions of clock states is an active research area, with several recently demonstrated implementations. Controlled Vocabulary Terms atomic clocks; optical squeezing
Frequency and its inverse, time, are the most accurately measured quantities. Historically, improvements in the accuracy of clocks have enabled advances in navigation, communication, and science. Since 1967, the definition of the International System (SI) second has been based on the frequency of a microwave transition in cesium, and present day cesium atomic clocks have a fractional uncertainty near 10-16. Recently, a new type of atomic clock based on optical transitions has been developed, with a current fractional uncertainty near 10-18 (approximately one second divided by the age of the universe), and they are rapidly improving. This talk presents a brief summary of the development of optical atomic clocks, with a focus on the Al+ quantum-logic clock developed at NIST. We discuss the current state-of-the-art in optical clock performance, and describe new applications in sensing and fundamental physics. Future directions in optical atomic clock research are also considered.
8half a century ago and have provided the definition of the second since 1967. The international atomic time (TAI) is currently kept by an ensemble of Cs clocks with a fractional uncertainty of Δν/ν0 ≈ 10 –15 , and some Cs fountain clocks 9,10 operate at even smaller uncertainties. Although Cs atomic clocks operate at the microwave transition of ν0 ≈ 9.2 GHz, using optical transition frequencies of several hundred terahertz should improve the fractional uncertainty Δν/ν0 by 4–5 orders of magnitude, as most measurement uncertainties Δν are independent of ν0 (except the Doppler shift Δ νD = (v/c)ν0, where v is the atomic velocity and c is the speed of light). The invention of the laser and the subsequent improvement of laser frequency stabilities 11 has allowed the realization of optical clocks to become a reality 2,3,12
The final chapter of this book considers some applications of ultracold atoms in addition to the study of Bose–Einstein condensates. These applications focus largely on the use of ultracold atoms for the purpose of constructing a highly accurate atomic clock. These clocks include atomic fountain clocks, which are presently used for the definition of the second. These clocks operate at microwave frequencies by observing the transitions between hyperfine split atomic ground states. More recent developments in atomic clocks utilize optical transitions between the ground state and an excited atomic state and typically utilize atoms trapped in an optical lattice.
The measurement on energy levels suitable for time standards can be made more precise with the use of neutral atom manipulation techniques. We have created a fountain of atoms where the measurement time of atoms in ballistic free-fall can be on the order of a fraction of a second. With these long measurement times, the linewidth of the transition between the ground state hyperfine transition of sodium was measured to be 2 Hz. Transitions in the optical frequency range could then have Q's of 1014 to 1015. In addition to creating high Q resonances, it is desirable to have a continuous, high density fountain of atoms. Towards this end, we have constructed an "atomic funnel" capable of creating a cold, high flux stream of atoms suitable for injection into a continuous atomic fountain. In the first embodiment of the funnel, the brightness of the atomic beam (defined as the number of atoms per second/( ΔvxΔvyΔvz) was increased by a factor of 3 × 103. With more recent improvements for both funneling more atoms from the hot atomic beam and better use of polarization gradient cooling to launch the atoms, we will describe how to improve the brightness enhancement by another four orders of magnitude.
Abstract : The grant as in support of a research program to explore the possibility of a microwave atomic clock based on an atomic fountain of cesium atoms. During the two year granting period, the following work was done: A large magneto-optic trap in a vapor cell was constructed where over 4x 10(exp 10) atoms were trapped at a density on the order of 10(exp 11) atoms/cu cm. This work increased the number of atoms optically trapped by a factor of -400 compared to previous work. The optical density of the atoms in this trap has a peak attenuation of e(-175). In an invited review article we examined the prospects for slow atom frequency standards. Most of the systematic effects that limit the current accuracy today's frequency standards decrease as the velocity of the atoms is reduced. We identified the one possible exception: collisions between ultra-cold atom in an atomic fountain could induce a phase shift that would ultimately limit the accuracy of the fountain clock. We brought the problem to the attention of B. Verhaar, who began a series of calculations on the effects of low energy collisions. jg p.4