arXiv:1104.4142

Microchip-Based Trapped-Atom Clocks

Vladan Vuletić, Ian D. Leroux, Monika Schleier-Smith

Published Apr 20, 2011• 0 citations
arXivHTMLPDF

Abstract

This is a chapter of a recently published book entitled Atom Chips, edited by Jakob Reichel and Vladan Vuletic. The contents of this chapter include: Basic Principles; Atomic-Fountain versus Trapped-Atom Clocks; Optical-Transition Clocks versus Microwave Clocks; Clocks with Magnetically Trapped Atoms--Fundamental Limits and Experimental Demonstrations; Readout in Trapped-Atom Clocks; and Spin Squeezing.

DOI
10.48550/arxiv.1104.4142

Related papers

Microchip‐Based Trapped‐Atom Clocks

Vladan Vuletić, Ian D. Leroux, Monika Schleier-Smith

In the absence of other fields, particles fall under gravity, which sets a practical limit on the single-measurement time T. Atomic fountains, where an ensemble of atoms is launched upwards into a ballistic flight region, allow one to increase the measurement time. Since the fractional accuracy of an atomic clock improves with increasing transition frequency, it is natural to consider the use of optical-frequency electronic transitions rather than microwave-frequency hyperfine transitions as the basis for a clock. Clocks operating on optical transitions have already surpassed the much more mature hyperfine-transition atomic-fountain clocks in accuracy, and further improvements are expected. In practice, however, the allowable atom number is severely limited by the onset of collision shifts which, as seen, are the bane of compact trapped-atom clocks. Spin squeezing of superpositions of clock states is an active research area, with several recently demonstrated implementations. Controlled Vocabulary Terms atomic clocks; optical squeezing

Wiley eBooks•Feb 9, 2011•3 citations

Other applications of laser cooling and trapping

Richard A. Dunlap

The final chapter of this book considers some applications of ultracold atoms in addition to the study of Bose–Einstein condensates. These applications focus largely on the use of ultracold atoms for the purpose of constructing a highly accurate atomic clock. These clocks include atomic fountain clocks, which are presently used for the definition of the second. These clocks operate at microwave frequencies by observing the transitions between hyperfine split atomic ground states. More recent developments in atomic clocks utilize optical transitions between the ground state and an excited atomic state and typically utilize atoms trapped in an optical lattice.

Institute of Physics eBooks•May 1, 2023•0 citations

Magnetic trapping on an atom chip

Dobrosława Bartoszek-Bober, Roman Panaś, Tomasz Kawalec

The article reviews briefly the rapidly evolving field of so-called atom chips for neutral atoms. Emphasis is placed on magnetic microtraps – on-chip Ioffe-Prichard and dimple trap issue is covered in some detail. The experimental setup for cooling and trapping 87Rb atoms is also presented together with some early results of on-chip magnetic trapping. Full Text: PDF References J. Schmiedmayer, "Guiding and trapping a neutral atom on a wire", Phys. Rev. A 52, R13 (1995). CrossRef M. H. Anderson, J. R. Ensher, M. R. Matthews, C. E. Wieman, and E. A. Cornell, "Observation of Bose-Einstein Condensation in a Dilute Atomic Vapor", Science 269, 198 (1995). CrossRef K. B. Davis, M.-O. Mewes, M. R. Andrews, N. J. van Druten, D. S. Durfee, D. M. Kurn et al., "Bose-Einstein Condensation in a Gas of Sodium Atoms", Phys. Rev. Lett. 75, 3969 (1995). CrossRef J. D. Weinstein, K. G. Libbrecht, "Microscopic magnetic traps for neutral atoms", Phys. Rev. A 52, 4004 (1995). CrossRef D. Müller, D. Z. Anderson, R. J. Grow, P. D. D. Schwindt, and E. A. Cornell, "Guiding Neutral Atoms Around Curves with Lithographically Patterned Current-Carrying Wires", Phys. Rev. Lett. 83, 5194 (1999). CrossRef N. H. Dekker, C. S. Lee, V. Lorent, J. H. Thywissen, S. P. Smith, M. Drndi et al., "Guiding Neutral Atoms on a Chip", Phys. Rev. Lett. 84, 1124 (2000). CrossRef J. Reichel, W. Hänsel, and T. W. Hänsch, "Atomic Micromanipulation with Magnetic Surface Traps", Phys. Rev. Lett. 83, 3398 (1999). CrossRef D. Cassettari, B. Hessmo, R. Folman, T. Maier, and J. Schmiedmayer, "Beam Splitter for Guided Atoms", Phys. Rev. Lett. 85, 5483 (2000). CrossRef M. A. Cirone, A. Negretti, T. Calarco, P. Krüger, J. Schmiedmayer, "A simple quantum gate with atom chips", Eur. Phys. J. D 35, 165 (2005). CrossRef W. Hänsel, P. Hommelhoff, T. W. Hänsch, and J. Reichel, "Bose–Einstein condensation on a microelectronic chip", Nature 413, 498 (2001). CrossRef H. Ott, J. Fortagh, G. Schlotterbeck, A. Grossmann, and C. Zimmermann, "Bose-Einstein Condensation in a Surface Microtrap", Phys. Rev. Lett. 87, 230401 (2001). CrossRef Y. Lin, I. Teper, C. Chin, V. Vuletić, "Impact of the Casimir-Polder Potential and Johnson Noise on Bose-Einstein Condensate Stability Near Surfaces", Phys. Rev. Lett. 92, 050404 (2004). CrossRef E. Salim, J. DeNatale, D. Farkas, K. Hudek, S. McBride, J. Michalchuk et al, "Compact, microchip-based systems for practical applications of ultracold atoms", Quantum Inf. Process. 10, 975 (2011). CrossRef S. Groth, Development, "Fabrication and Characterisation of Atom Chips", doctoral dissertation. (2006). R. Folman, P. Krüger, J. Schmiedmayer, J. Denschlag, C. Henkel, "Microscopic atom optics: From wires to an atom chip", Adv. At. Mol. Opt. Phys. 48, 263 (2002). CrossRef A. Arnold, Preparation and Manipulation of an 87Rb Bose-Einstein Condensate (University of Sussex 1999), PhD thesis. D. M. Farkas, K. M. Hudek, E. A. Salim, S. R. Segal, M. B. Squires, and D. Z. Anderson, "A compact, transportable, microchip-based system for high repetition rate production of Bose–Einstein condensates ", Appl. Phys. Lett. 96, 093102 (2010). CrossRef K. Dieckmann, R. J. C. Spreeuw, M. Weidemüller, and J. T. M. Walraven, "Two-dimensional magneto-optical trap as a source of slow atoms", Phys. Rev. A 58, 3891 (1998). CrossRef W. Petrich, M. H. Anderson, J. R. Ensher, and E. A. Cornell, "Behavior of atoms in a compressed magneto-optical trap", J. Opt. Soc. Am. B, 11, 1332 (1994). CrossRef

Photonics Letters of Poland•Oct 1, 2013•1 citation

Microchips for single atom detection and spin squeezing

Monika Schleier-Smith, Ian D. Leroux, Yu‐Ju Lin +2 more

Magnetic microtraps for ultracold atoms combine tight confinement, long storage times, high degree of control over the atomic position, and good optical access. Atom detection can be implemented via fluorescence, absorption, or dispersive measurements. All three types of measurements can be enhanced by an optical resonator, where the enhancement factor is proportional to the resonator finesseF. In the limit of negligible detector counts, in a setup where the detector registers n counts per atom in a fluorescence measurement, the atom number resolution is DeltaNf= (N/n)1/2for a fluorescence measurement, and DeltaNa= (1/4N)1/2for an absorption measurement. This means that absorption and fluorescence measurements perform similarly for one atom, but that the absorption measurement is superior for N >1. However, in absorption measurements the number of atoms must remain sufficiently small for the atomic absorption not to deteriorate the resonator finesse. Larger samples can be probed by dispersive measurements, where the tuning of the resonator due to the atomic index of refraction is measured. In the absence of technical noise, the corresponding atom number resolution is independent of detuning from the atomic transition, and given by DeltaNd= (1/n)1/2. Using fluorescence detection in a resonator of finesse F=8000, we detect two counts per atom in 250 mus, enabling single-atom detection with 75% efficiency (Teper et al., 2006). Absorption detection with 3.3% transmission attenuation enables us to measure small samples with up to 10 atoms with a resolution of about one atom. Absorptive and dispersive detection are interesting in that the resolution is not decreased with higher atom number. The reason is that both rely on the forward scattered signal, where the fields emitted by different atoms add coherently. These methods therefore allow non-destructive measurements below the atom-number shot noise, provided that the optical depth of the sample exceeds unity. We have realized an optical depth of several thousand inside the resonator, which should enable trapped-atom detection significantly below the shot-noise limit. If the detection is applied in a state-selective manner to a sample of two-level atoms (Geremia et al., 2004), conditional spin squeezing results. Such squeezing of the pseudo-spin for an atomic clock transition can be used to realize a hyperfine atomic clock on a microchip (Treutlin et al., 2004) that operates below the atom number shot noise limit (standard quantum limit). We report experimental progress towards pseudo-spin squeezing for87Rb atoms trapped on the microchip.

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•Jun 1, 2007•0 citations

Creating Spin Squeezing in a Compact Atomic Clock

Théo Laudat, Konstantin Ott, Meng-Zi Huang +5 more

We demonstrate spontaneous spin squeezing in a trapped-atom clock on a chip (TACC) using condensed atoms and present progress towards a squeezed clock with thermal atoms, which uses a fiber microcavity on the chip.

Quantum Information and Measurement (QIM)•Jan 1, 2017•0 citations

Towards a quantum-enhanced trapped-atom clock on a chip

Meng-Zi Huang, Tommaso Mazzoni, Carlos L. Garrido Alzar +1 more

We report preliminary results of a quantum-enhanced atom chip clock. Using ultracold rubidium atoms inside an on-chip optical cavity, we investigate light-induced spin squeezing and non-destructive measurements at 10E-13 level of relative frequency stability.

Quantum Information and Measurement (QIM)•Jan 1, 2019•1 citation
This is a chapter of a recently published book entitled Atom Chips, edited by Jakob Reichel and Vladan Vuletic. The contents of this chapter include: Basic Principles; Atomic-Fountain versus Trapped-Atom Clocks; Optical-Transition Clocks versus Microwave Clocks; Clocks with Magnetically Trapped Atoms--Fundamental Limits and Experimental Demonstrations; Readout in Trapped-Atom Clocks; and Spin Squeezing.
In the absence of other fields, particles fall under gravity, which sets a practical limit on the single-measurement time T. Atomic fountains, where an ensemble of atoms is launched upwards into a ballistic flight region, allow one to increase the measurement time. Since the fractional accuracy of an atomic clock improves with increasing transition frequency, it is natural to consider the use of optical-frequency electronic transitions rather than microwave-frequency hyperfine transitions as the basis for a clock. Clocks operating on optical transitions have already surpassed the much more mature hyperfine-transition atomic-fountain clocks in accuracy, and further improvements are expected. In practice, however, the allowable atom number is severely limited by the onset of collision shifts which, as seen, are the bane of compact trapped-atom clocks. Spin squeezing of superpositions of clock states is an active research area, with several recently demonstrated implementations. Controlled Vocabulary Terms atomic clocks; optical squeezing
The final chapter of this book considers some applications of ultracold atoms in addition to the study of Bose–Einstein condensates. These applications focus largely on the use of ultracold atoms for the purpose of constructing a highly accurate atomic clock. These clocks include atomic fountain clocks, which are presently used for the definition of the second. These clocks operate at microwave frequencies by observing the transitions between hyperfine split atomic ground states. More recent developments in atomic clocks utilize optical transitions between the ground state and an excited atomic state and typically utilize atoms trapped in an optical lattice.
The article reviews briefly the rapidly evolving field of so-called atom chips for neutral atoms. Emphasis is placed on magnetic microtraps – on-chip Ioffe-Prichard and dimple trap issue is covered in some detail. The experimental setup for cooling and trapping 87Rb atoms is also presented together with some early results of on-chip magnetic trapping. Full Text: PDF References J. Schmiedmayer, "Guiding and trapping a neutral atom on a wire", Phys. Rev. A 52, R13 (1995). CrossRef M. H. Anderson, J. R. Ensher, M. R. Matthews, C. E. Wieman, and E. A. Cornell, "Observation of Bose-Einstein Condensation in a Dilute Atomic Vapor", Science 269, 198 (1995). CrossRef K. B. Davis, M.-O. Mewes, M. R. Andrews, N. J. van Druten, D. S. Durfee, D. M. Kurn et al., "Bose-Einstein Condensation in a Gas of Sodium Atoms", Phys. Rev. Lett. 75, 3969 (1995). CrossRef J. D. Weinstein, K. G. Libbrecht, "Microscopic magnetic traps for neutral atoms", Phys. Rev. A 52, 4004 (1995). CrossRef D. Müller, D. Z. Anderson, R. J. Grow, P. D. D. Schwindt, and E. A. Cornell, "Guiding Neutral Atoms Around Curves with Lithographically Patterned Current-Carrying Wires", Phys. Rev. Lett. 83, 5194 (1999). CrossRef N. H. Dekker, C. S. Lee, V. Lorent, J. H. Thywissen, S. P. Smith, M. Drndi et al., "Guiding Neutral Atoms on a Chip", Phys. Rev. Lett. 84, 1124 (2000). CrossRef J. Reichel, W. Hänsel, and T. W. Hänsch, "Atomic Micromanipulation with Magnetic Surface Traps", Phys. Rev. Lett. 83, 3398 (1999). CrossRef D. Cassettari, B. Hessmo, R. Folman, T. Maier, and J. Schmiedmayer, "Beam Splitter for Guided Atoms", Phys. Rev. Lett. 85, 5483 (2000). CrossRef M. A. Cirone, A. Negretti, T. Calarco, P. Krüger, J. Schmiedmayer, "A simple quantum gate with atom chips", Eur. Phys. J. D 35, 165 (2005). CrossRef W. Hänsel, P. Hommelhoff, T. W. Hänsch, and J. Reichel, "Bose–Einstein condensation on a microelectronic chip", Nature 413, 498 (2001). CrossRef H. Ott, J. Fortagh, G. Schlotterbeck, A. Grossmann, and C. Zimmermann, "Bose-Einstein Condensation in a Surface Microtrap", Phys. Rev. Lett. 87, 230401 (2001). CrossRef Y. Lin, I. Teper, C. Chin, V. Vuletić, "Impact of the Casimir-Polder Potential and Johnson Noise on Bose-Einstein Condensate Stability Near Surfaces", Phys. Rev. Lett. 92, 050404 (2004). CrossRef E. Salim, J. DeNatale, D. Farkas, K. Hudek, S. McBride, J. Michalchuk et al, "Compact, microchip-based systems for practical applications of ultracold atoms", Quantum Inf. Process. 10, 975 (2011). CrossRef S. Groth, Development, "Fabrication and Characterisation of Atom Chips", doctoral dissertation. (2006). R. Folman, P. Krüger, J. Schmiedmayer, J. Denschlag, C. Henkel, "Microscopic atom optics: From wires to an atom chip", Adv. At. Mol. Opt. Phys. 48, 263 (2002). CrossRef A. Arnold, Preparation and Manipulation of an 87Rb Bose-Einstein Condensate (University of Sussex 1999), PhD thesis. D. M. Farkas, K. M. Hudek, E. A. Salim, S. R. Segal, M. B. Squires, and D. Z. Anderson, "A compact, transportable, microchip-based system for high repetition rate production of Bose–Einstein condensates ", Appl. Phys. Lett. 96, 093102 (2010). CrossRef K. Dieckmann, R. J. C. Spreeuw, M. Weidemüller, and J. T. M. Walraven, "Two-dimensional magneto-optical trap as a source of slow atoms", Phys. Rev. A 58, 3891 (1998). CrossRef W. Petrich, M. H. Anderson, J. R. Ensher, and E. A. Cornell, "Behavior of atoms in a compressed magneto-optical trap", J. Opt. Soc. Am. B, 11, 1332 (1994). CrossRef
Magnetic microtraps for ultracold atoms combine tight confinement, long storage times, high degree of control over the atomic position, and good optical access. Atom detection can be implemented via fluorescence, absorption, or dispersive measurements. All three types of measurements can be enhanced by an optical resonator, where the enhancement factor is proportional to the resonator finesseF. In the limit of negligible detector counts, in a setup where the detector registers n counts per atom in a fluorescence measurement, the atom number resolution is DeltaNf= (N/n)1/2for a fluorescence measurement, and DeltaNa= (1/4N)1/2for an absorption measurement. This means that absorption and fluorescence measurements perform similarly for one atom, but that the absorption measurement is superior for N >1. However, in absorption measurements the number of atoms must remain sufficiently small for the atomic absorption not to deteriorate the resonator finesse. Larger samples can be probed by dispersive measurements, where the tuning of the resonator due to the atomic index of refraction is measured. In the absence of technical noise, the corresponding atom number resolution is independent of detuning from the atomic transition, and given by DeltaNd= (1/n)1/2. Using fluorescence detection in a resonator of finesse F=8000, we detect two counts per atom in 250 mus, enabling single-atom detection with 75% efficiency (Teper et al., 2006). Absorption detection with 3.3% transmission attenuation enables us to measure small samples with up to 10 atoms with a resolution of about one atom. Absorptive and dispersive detection are interesting in that the resolution is not decreased with higher atom number. The reason is that both rely on the forward scattered signal, where the fields emitted by different atoms add coherently. These methods therefore allow non-destructive measurements below the atom-number shot noise, provided that the optical depth of the sample exceeds unity. We have realized an optical depth of several thousand inside the resonator, which should enable trapped-atom detection significantly below the shot-noise limit. If the detection is applied in a state-selective manner to a sample of two-level atoms (Geremia et al., 2004), conditional spin squeezing results. Such squeezing of the pseudo-spin for an atomic clock transition can be used to realize a hyperfine atomic clock on a microchip (Treutlin et al., 2004) that operates below the atom number shot noise limit (standard quantum limit). We report experimental progress towards pseudo-spin squeezing for87Rb atoms trapped on the microchip.