Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)

Recoil effects in microwave atomic frequency standards: preliminary results

Peter Wolf, S. Bize, Andr  Clairon, Arnaud Landragin, Philippe Laurent, P. Lemonde, Ch. J. Bordé

Published Nov 13, 2002• 1 citation
Publisher

Abstract

We investigate theoretically and by numerical simulations the effects of the atomic recoil on the frequency and fringe contrast of microwave atomic frequency standards. Such effects arise because of the influence of external degrees of freedom on the phases and the spatial positions of the interfering wave packets. We show under which conditions such effects lead to a frequency shift and examine the loss of contrast of the interference signal (Ramsey fringes). We use an interferometric description to model the frequency standards, treating simultaneously internal and external degrees of freedom. We consider multiple momentum exchanges in 3D between the atoms and the standing microwave field inside the cavity leading to a large number of wave packets that leave the cavity with different momenta. At detection, these wave packets interfere giving rise to Ramsey fringes that are modulated by the interference of the external states of the wave packets. Similar treatments have proved efficient when treating ID recoil effects in standing laser waves. We apply this theoretical model numerically to laser cooled atomic fountain frequency standards and investigate the behaviour of the observed signal as a function of the frequency standard parameters (microwave power, launching height, etc.). Finally, we discuss possible experimental methods that could be used to observe such effects.

DOI
10.1109/freq.2001.956157

Related papers

Atom-interferometric studies of light scattering

Scott Beattie, B. Barrett, I. Y. Chan +3 more

We have used an echo-type atom interferometer that manipulates laser-cooled atoms in a single ground state to investigate the effect of light scattering from pulsed and continuous-wave light. The interferometer uses two off-resonant standing-wave pulses applied at times $t=0$ and $t=T$ to diffract and recombine momentum states separated by $2\ensuremath{\hbar}k$ at $t=2T$. Matter wave interference is associated with the formation of a density grating with period $\ensuremath{\lambda}/2$ in the vicinity of this echo time. The grating contrast is measured by recording the intensity of coherently backscattered light. The interferometer is perturbed by an additional pulse applied at $t=2T\ensuremath{-}\ensuremath{\delta}T$ or by continuous-wave background light. If the additional pulse is a standing wave, the momentum states interfering at $t=2T$ are displaced and the grating contrast can be completely recovered due to constructive interference. In this case, the contrast shows a periodic modulation at the atomic recoil frequency as a function of $\ensuremath{\delta}T$. In a recent work, it was shown that the atomic recoil frequency can be measured easily and precisely when using coherence functions to model the signal shape. This paper provides an alternative description of the signal shape through an analytical calculation of echo formation in the presence of an additional standing-wave pulse. Using this treatment, it is possible to model the effects of spontaneous emission and spatial profile of the laser beam on the signal shape. Additionally, the theory predicts scaling laws as a function of the pulse area and the number of additional standing-wave pulses. These scaling laws are investigated experimentally and can be exploited to improve precision measurements of the atomic recoil frequency. We also show that coherence functions can be used to make a direct measurement of the populations of momentum states associated with the ground state under conditions where the Doppler-broadened velocity distribution of the sample is much larger than the recoil velocity. These measurements are consistent with Monte Carlo wave-function simulations. If the additional pulse is a traveling wave, we find that the grating contrast measured as a function of $\ensuremath{\delta}T$ can be modeled by a quasiperiodic coherence function as in previous experiments that utilized atomic beams. In this work, we investigate the dependence of the photon scattering rate on the intensity and detuning of the traveling wave. We also study the effects of perturbing the interferometer with continuous-wave light and find that the dependence of the photon scattering rate on the intensity and detuning of the perturbing field is consistent with expectations.

Physical Review A•Jul 29, 2009•10 citations

Distributed cavity phase shifts and microwave photon recoils

Chad Fertig, Ruoxin Li, J.I. Rees +1 more

Examines cylindrical TE/sub 011/ microwave cavities and finds large phase shifts of the microwave field near the edges of the cut-off waveguide apertures, where there are nodes in the field. The phase shifts lead to a potential distributed cavity phase shift for atomic clocks. Using an additional larger diameter cut-off waveguide section can effectively exclude the nodes and the large phase shifts from the atomic trajectories. It has been suggested that recoils from the absorption of microwave photons lead to frequency shift and also a loss of fringe contrast. We present measurements of the contrast for up to 2 19/spl pi//2 pulses and find no loss of contrast beyond that expected from measuring microwave field inhomogeneities with up to 19/spl pi/ Rabi pulses.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Jun 25, 2003•10 citations

Measuring the atomic recoil frequency using a modified grating-echo atom interferometer

B. Barrett, A. Carew, Scott Beattie +1 more

We describe progress toward a precise measurement of the recoil energy of an atom measured using a modified grating-echo atom interferometer (AI) that involves three standing-wave (sw) pulses. With this technique, an additional sw pulse is used to shift the phase of excited momentum states, which produces a modulation in the contrast of the interference pattern. The signal exhibits narrow fringes that revive periodically at twice the two-photon recoil frequency, $2{\ensuremath{\omega}}_{q}$, as a function of the onset time of the pulse. Experiments are performed using samples of laser-cooled rubidium atoms with temperatures $\ensuremath{\lesssim}$5 $\ensuremath{\mu}$K in a nonmagnetic apparatus. We demonstrate a measurement of ${\ensuremath{\omega}}_{q}$ with a statistical uncertainty of 37 parts per ${10}^{9}$ (ppb) on a time scale of $\ensuremath{\sim}$45 ms in 14 h. Further statistical improvements are anticipated by extending this time scale and narrowing the signal fringe width. However, the total systematic uncertainty is estimated to be $\ensuremath{\sim}$6 parts per ${10}^{6}$ (ppm). We describe methods of reducing these systematic errors.

arXiv:1209.5624•Physical Review A•Mar 25, 2013•21 citations

Technique for measuring atomic recoil frequency using coherence functions

Scott Beattie, B. Barrett, I. Y. Chan +3 more

We have developed a technique for measuring the atomic recoil frequency using a single-state echo-type atom interferometer that manipulates laser-cooled atoms in the ground state. The interferometer relies on momentum-state interference due to two standing-wave pulses that produce density gratings. The interference is modified by applying a third standing-wave pulse during the interferometer pulse sequence. As a result, the grating contrast exhibits periodic revivals at the atomic recoil frequency ${\ensuremath{\omega}}_{r}$ as a function of the time at which the third pulse is applied, allowing ${\ensuremath{\omega}}_{r}$ to be measured easily and precisely. The contrast is accurately described by a coherence function, which is the Fourier transform of the momentum distribution, produced by the third pulse and by the theory of echo formation. If the third pulse is a traveling wave, loss of grating contrast is observed, an effect also described by a coherence function. The decay of the grating contrast as a function of continuous-wave light intensity is used to infer the cross section for photon absorption.

Physical Review A•Feb 13, 2009•12 citations

A New Technique for Measuring Atomic Recoil Frequency Using Coherence Functions

Scott Beattie, B. Barrett, I. Y. Chan +3 more

We have developed a technique for measuring the atomic recoil frequency using a single-state echo-type atom interferometer that manipulates laser-cooled atoms in the ground state. The interferometer relies on momentum-state interference due to two standing-wave pulses that produce density gratings. The interference is modified by applying a third standing-wave pulse during the interferometer pulse sequence. As a result, the grating contrast exhibits periodic revivals at the atomic recoil frequency r as a function of the time at which the third pulse is applied, allowing r to be measured easily and precisely. The contrast is accurately described by a coherence function, which is the Fourier transform of the momentum distribution, produced by the third pulse and by the theory of echo formation. If the third pulse is a traveling wave, loss of grating contrast is observed, an effect also described by a coherence function. The decay of the grating contrast as a function of continuous-wave light intensity is used to infer the cross section for photon absorption.

Bulletin of the American Physical Society•May 22, 2009•0 citations

Influence of external potentials on optical Ramsey fringes in atomic interferometry

Jürgen Audretsch, Karl-Peter Marzlin

The interaction of an atomic beam with four traveling-wave laser beams leads to optically induced Ramsey fringes in the atomic beam. This experimental setup has been used as an optical frequency standard as well as a matter-wave interferometer. We calculate for two-level atoms the shift of the fringes due to the influence of fairly general external forces in lowest order of a perturbation approach. A comparison with the phase shift found in a corresponding WKB treatment of the interaction geometry is made. The consequences of beam reversal and cooling of the atomic beam are studied. As an application, we treat the linear acceleration and rotation of the interferometer and discuss the influence of space-time curvature.

Physical Review A•May 1, 1993•10 citations
We investigate theoretically and by numerical simulations the effects of the atomic recoil on the frequency and fringe contrast of microwave atomic frequency standards. Such effects arise because of the influence of external degrees of freedom on the phases and the spatial positions of the interfering wave packets. We show under which conditions such effects lead to a frequency shift and examine the loss of contrast of the interference signal (Ramsey fringes). We use an interferometric description to model the frequency standards, treating simultaneously internal and external degrees of freedom. We consider multiple momentum exchanges in 3D between the atoms and the standing microwave field inside the cavity leading to a large number of wave packets that leave the cavity with different momenta. At detection, these wave packets interfere giving rise to Ramsey fringes that are modulated by the interference of the external states of the wave packets. Similar treatments have proved efficient when treating ID recoil effects in standing laser waves. We apply this theoretical model numerically to laser cooled atomic fountain frequency standards and investigate the behaviour of the observed signal as a function of the frequency standard parameters (microwave power, launching height, etc.). Finally, we discuss possible experimental methods that could be used to observe such effects.
We have used an echo-type atom interferometer that manipulates laser-cooled atoms in a single ground state to investigate the effect of light scattering from pulsed and continuous-wave light. The interferometer uses two off-resonant standing-wave pulses applied at times t=0t=0t=0 and t=Tt=Tt=T to diffract and recombine momentum states separated by $2\ensuremath{\hbar}k$ at t=2Tt=2Tt=2T. Matter wave interference is associated with the formation of a density grating with period $\ensuremath{\lambda}/2$ in the vicinity of this echo time. The grating contrast is measured by recording the intensity of coherently backscattered light. The interferometer is perturbed by an additional pulse applied at $t=2T\ensuremath{-}\ensuremath{\delta}T$ or by continuous-wave background light. If the additional pulse is a standing wave, the momentum states interfering at t=2Tt=2Tt=2T are displaced and the grating contrast can be completely recovered due to constructive interference. In this case, the contrast shows a periodic modulation at the atomic recoil frequency as a function of $\ensuremath{\delta}T$. In a recent work, it was shown that the atomic recoil frequency can be measured easily and precisely when using coherence functions to model the signal shape. This paper provides an alternative description of the signal shape through an analytical calculation of echo formation in the presence of an additional standing-wave pulse. Using this treatment, it is possible to model the effects of spontaneous emission and spatial profile of the laser beam on the signal shape. Additionally, the theory predicts scaling laws as a function of the pulse area and the number of additional standing-wave pulses. These scaling laws are investigated experimentally and can be exploited to improve precision measurements of the atomic recoil frequency. We also show that coherence functions can be used to make a direct measurement of the populations of momentum states associated with the ground state under conditions where the Doppler-broadened velocity distribution of the sample is much larger than the recoil velocity. These measurements are consistent with Monte Carlo wave-function simulations. If the additional pulse is a traveling wave, we find that the grating contrast measured as a function of $\ensuremath{\delta}T$ can be modeled by a quasiperiodic coherence function as in previous experiments that utilized atomic beams. In this work, we investigate the dependence of the photon scattering rate on the intensity and detuning of the traveling wave. We also study the effects of perturbing the interferometer with continuous-wave light and find that the dependence of the photon scattering rate on the intensity and detuning of the perturbing field is consistent with expectations.
Examines cylindrical TE/sub 011/ microwave cavities and finds large phase shifts of the microwave field near the edges of the cut-off waveguide apertures, where there are nodes in the field. The phase shifts lead to a potential distributed cavity phase shift for atomic clocks. Using an additional larger diameter cut-off waveguide section can effectively exclude the nodes and the large phase shifts from the atomic trajectories. It has been suggested that recoils from the absorption of microwave photons lead to frequency shift and also a loss of fringe contrast. We present measurements of the contrast for up to 2 19/spl pi//2 pulses and find no loss of contrast beyond that expected from measuring microwave field inhomogeneities with up to 19/spl pi/ Rabi pulses.
We describe progress toward a precise measurement of the recoil energy of an atom measured using a modified grating-echo atom interferometer (AI) that involves three standing-wave (sw) pulses. With this technique, an additional sw pulse is used to shift the phase of excited momentum states, which produces a modulation in the contrast of the interference pattern. The signal exhibits narrow fringes that revive periodically at twice the two-photon recoil frequency, $2{\ensuremath{\omega}}_{q}$, as a function of the onset time of the pulse. Experiments are performed using samples of laser-cooled rubidium atoms with temperatures $\ensuremath{\lesssim}$5 $\ensuremath{\mu}$K in a nonmagnetic apparatus. We demonstrate a measurement of ${\ensuremath{\omega}}_{q}$ with a statistical uncertainty of 37 parts per 109{10}^{9}109 (ppb) on a time scale of $\ensuremath{\sim}$45 ms in 14 h. Further statistical improvements are anticipated by extending this time scale and narrowing the signal fringe width. However, the total systematic uncertainty is estimated to be $\ensuremath{\sim}$6 parts per 106{10}^{6}106 (ppm). We describe methods of reducing these systematic errors.
We have developed a technique for measuring the atomic recoil frequency using a single-state echo-type atom interferometer that manipulates laser-cooled atoms in the ground state. The interferometer relies on momentum-state interference due to two standing-wave pulses that produce density gratings. The interference is modified by applying a third standing-wave pulse during the interferometer pulse sequence. As a result, the grating contrast exhibits periodic revivals at the atomic recoil frequency ${\ensuremath{\omega}}_{r}$ as a function of the time at which the third pulse is applied, allowing ${\ensuremath{\omega}}_{r}$ to be measured easily and precisely. The contrast is accurately described by a coherence function, which is the Fourier transform of the momentum distribution, produced by the third pulse and by the theory of echo formation. If the third pulse is a traveling wave, loss of grating contrast is observed, an effect also described by a coherence function. The decay of the grating contrast as a function of continuous-wave light intensity is used to infer the cross section for photon absorption.
We have developed a technique for measuring the atomic recoil frequency using a single-state echo-type atom interferometer that manipulates laser-cooled atoms in the ground state. The interferometer relies on momentum-state interference due to two standing-wave pulses that produce density gratings. The interference is modified by applying a third standing-wave pulse during the interferometer pulse sequence. As a result, the grating contrast exhibits periodic revivals at the atomic recoil frequency r as a function of the time at which the third pulse is applied, allowing r to be measured easily and precisely. The contrast is accurately described by a coherence function, which is the Fourier transform of the momentum distribution, produced by the third pulse and by the theory of echo formation. If the third pulse is a traveling wave, loss of grating contrast is observed, an effect also described by a coherence function. The decay of the grating contrast as a function of continuous-wave light intensity is used to infer the cross section for photon absorption.
The interaction of an atomic beam with four traveling-wave laser beams leads to optically induced Ramsey fringes in the atomic beam. This experimental setup has been used as an optical frequency standard as well as a matter-wave interferometer. We calculate for two-level atoms the shift of the fringes due to the influence of fairly general external forces in lowest order of a perturbation approach. A comparison with the phase shift found in a corresponding WKB treatment of the interaction geometry is made. The consequences of beam reversal and cooling of the atomic beam are studied. As an application, we treat the linear acceleration and rotation of the interferometer and discuss the influence of space-time curvature.